Model |
PBZ20-60 SR |
PBZ20-80 SR |
PBZ20-100 SR |
PBZ40-30 SR |
PBZ40-40 SR |
PBZ40-50 SR |
Input Rating |
|
|
|
|
|
|
Nominal input voltage |
200 Vac to 240 Vac |
200 Vac to 240 Vac |
200 Vac to 240 Vac |
200 Vac to 240 Vac |
200 Vac to 240 Vac |
200 Vac to 240 Vac |
Voltage range |
180 Vac to 250 Vac |
180 Vac to 250 Vac |
180 Vac to 250 Vac |
180 Vac to 250 Vac |
180 Vac to 250 Vac |
180 Vac to 250 Vac |
Frequency range |
47 Hz to 63 Hz |
47 Hz to 63 Hz |
47 Hz to 63 Hz |
47 Hz to 63 Hz |
47 Hz to 63 Hz |
47 Hz to 63 Hz |
Current |
15Aac or less |
20Aac or less |
25Aac or less |
15Aac or less |
20Aac or less |
25Aac or less |
Inrush current |
120Apeak or less |
160Apeak or less |
200Apeak or less |
120Apeak or less |
160Apeak or less |
200Apeak or less |
Power |
2700VA or less |
3600VA or less |
4500VA or less |
2700VA or less |
3600VA or less |
4500VA or less |
Power factor |
0.95 TYP (when the input voltage is 200 V) |
0.95 TYP (when the input voltage is 200 V) |
0.95 TYP (when the input voltage is 200 V) |
0.95 TYP (when the input voltage is 200 V) |
0.95 TYP (when the input voltage is 200 V) |
0.95 TYP (when the input voltage is 200 V) |
Output rating |
|
|
|
|
|
|
Power |
1200W |
1600W |
2000W |
1200W |
1600W |
2000W |
Voltage |
± 20 V |
± 20 V |
± 20 V |
± 40 V |
± 40 V |
± 40 V |
Current |
± 60 A |
± 80 A |
± 100 A |
± 30 A |
± 40 A |
± 50 A |
Output terminal |
|
|
|
|
|
|
Output terminal |
Rear panel output terminals |
Rear panel output terminals |
Rear panel output terminals |
Rear panel output terminals |
Rear panel output terminals |
Rear panel output terminals |
Isolation voltage |
500 Vdc Only the output’s COM terminal can be grounded |
500 Vdc Only the output’s COM terminal can be grounded |
500 Vdc Only the output’s COM terminal can be grounded |
500 Vdc Only the output’s COM terminal can be grounded |
500 Vdc Only the output’s COM terminal can be grounded |
500 Vdc Only the output’s COM terminal can be grounded |
Constant Voltage (CV) |
|
|
|
|
|
|
DC Voltage |
|
|
|
|
|
|
Bipolar mode |
0 V to ± (105 % of rating) |
0 V to ± (105 % of rating) |
0 V to ± (105 % of rating) |
0 V to ± (105 % of rating) |
0 V to ± (105 % of rating) |
0 V to ± (105 % of rating) |
Unipolar mode |
0 V to ± (105 % of rating) |
0 V to ± (105 % of rating) |
0 V to ± (105 % of rating) |
0 V to ± (105 % of rating) |
0 V to ± (105 % of rating) |
0 V to ± (105 % of rating) |
Fine feature |
± 5% of rating |
± 5% of rating |
± 5% of rating |
± 5% of rating |
± 5% of rating |
± 5% of rating |
Resolution |
0.001 V (0.0001 V for the fine feature) |
0.001 V (0.0001 V for the fine feature) |
0.001 V (0.0001 V for the fine feature) |
0.001 V (0.0001 V for the fine feature) |
0.001 V (0.0001 V for the fine feature) |
0.001 V (0.0001 V for the fine feature) |
Accuracy |
± (0.05 % of setting + 0.05 % of rating) |
± (0.05 % of setting + 0.05 % of rating) |
± (0.05 % of setting + 0.05 % of rating) |
± (0.05 % of setting + 0.05 % of rating) |
± (0.05 % of setting + 0.05 % of rating) |
± (0.05 % of setting + 0.05 % of rating) |
Temperature coefficient |
±100 ppm / °C of rating (TYP) |
±100 ppm / °C of rating (TYP) |
±100 ppm / °C of rating (TYP) |
±100 ppm / °C of rating (TYP) |
±100 ppm / °C of rating (TYP) |
±100 ppm / °C of rating (TYP) |
AC Voltage |
|
|
|
|
|
|
Settable range |
0.00 Vpp to (210 % of rating) pp |
0.00 Vpp to (210 % of rating) pp |
0.00 Vpp to (210 % of rating) pp |
0.00 Vpp to (210 % of rating) pp |
0.00 Vpp to (210 % of rating) pp |
0.00 Vpp to (210 % of rating) pp |
Resolution |
0.01 V |
0.01 V |
0.01 V |
0.1 V |
0.1 V |
0.1 V |
Accuracy |
± 0.5 % of rating |
± 0.5 % of rating |
± 0.5 % of rating |
± 0.5 % of rating |
± 0.5 % of rating |
± 0.5 % of rating |
Settable range |
0.01 Hz to 100.00 kHz |
0.01 Hz to 100.00 kHz |
0.01 Hz to 100.00 kHz |
0.01 Hz to 100.00 kHz |
0.01 Hz to 100.00 kHz |
0.01 Hz to 100.00 kHz |
Constant
voltage
characteristics |
|
|
|
|
|
|
Frequency response |
DC to 100 kHz ( -3 dB) (TYP) |
DC to 100 kHz ( -3 dB) (TYP) |
DC to 100 kHz ( -3 dB) (TYP) |
DC to 100 kHz ( -3 dB) (TYP) |
DC to 100 kHz ( -3 dB) (TYP) |
DC to 100 kHz ( -3 dB) (TYP) |
Response |
3.5 μs, 10 μs, 35 μs, 100 μs |
3.5 μs, 10 μs, 35 μs, 100 μs |
3.5 μs, 10 μs, 35 μs, 100 μs |
3.5 μs, 10 μs, 35 μs, 100 μs |
3.5 μs, 10 μs, 35 μs, 100 μs |
3.5 μs, 10 μs, 35 μs, 100 μs |
Overshoot |
5 % or less (TYP) |
5 % or less (TYP) |
5 % or less (TYP) |
5 % or less (TYP) |
5 % or less (TYP) |
5 % or less (TYP) |
Ripple
noise |
p-p: 30 mV (TYP)
rms: 3 mV |
p-p: 30 mV (TYP)
rms: 3 mV |
p-p: 30 mV (TYP)
rms: 3 mV |
p-p: 30 mV (TYP)
rms: 6 mV |
p-p: 30 mV (TYP)
rms: 6 mV |
p-p: 30 mV (TYP)
rms: 6 mV |
Load effect |
± (0.005 % of setting + 1 mV) |
± (0.005 % of setting + 1 mV) |
± (0.005 % of setting + 1 mV) |
± (0.005 % of setting + 1 mV) |
± (0.005 % of setting + 1 mV) |
± (0.005 % of setting + 1 mV) |
Source effect |
± (0.005 % of setting + 1 mV) |
± (0.005 % of setting + 1 mV) |
± (0.005 % of setting + 1 mV) |
± (0.005 % of setting + 1 mV) |
± (0.005 % of setting + 1 mV) |
± (0.005 % of setting + 1 mV) |
Reviews