Kikusui PLZ4005WH2 DC Electronic Load 10V-1000V 0-80A 4kW

£7196.00 (£8,635.20 inc VAT)

Available on back-order

Description


Kikusui PLZ4005WH2 DC Electronic Load

The Kikusui PLZ4005WH2 (10V-1000V 0-80A 4kW) High Voltage DC Electronic Load (CC/CR/CV/CP/ARB) forms part of the new Kikusui PLZ-5WH2 series where durable, reliable ingenuity meets multifunctional high power design. Providing a choice of five power range line-ups, from 1 kW bench top style model to a high power floor standing model that can sink up to 20 kW of power in a single unit, now making it easy to select the correct power electronic load to test your EUT at full power. Load simulation can be achieved faster than ever before thanks to the reliable, high speed design of the PLZ-5WH current control circuits. Accurate current measurements can be made with the electronic loads extremely high setting resolution. A colour LCD display allows user-friendly front panel operation.
RS232C, USB, and LAN digital interfaces are included as standard for simple integration into any system.

    Features:

  • Equipped with four modes (Constant Current, Constant Resistance Constant Voltage, Constant Power) plus Arbitrary IV Characteristics (ARB) mode to reproduce nonlinear load characteristics
  • Load On/Off
  • Cutoff Function
  • Changing the Response Speed
  • Soft Start
  • Sequence control functionality enables actual-load simulations
  • Parallel operation enables scalability
  • Data Logging Function
  • Integrated Data Function
  • Saving Measurement Data
  • Pulse Function
  • Sine Function
  • Sequence Function
  • Alarm Function
  • ABC Preset Memories
  • Setup Memory
  • External Control
  • Current and Voltage Monitor
  • USB Keyboard
  • Synchronised Operation
  • Remote Sensing
  • Comes with LAN, RS232C and USB communication interfaces installed as a standard feature. *GPIB Option.

Product Videos

Documentation

PLZ-5WH2 Specifications
Model PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Ratings
Operating voltage (DC) 10 V to 1000 V 10 V to 1000 V 10 V to 1000 V 10 V to 1000 V 10 V to 1000 V
Power 1000W 2000W 4000W 12000W 20000W
Current 20A 40A 80A 240A 400A
DC INPUT terminal’s isolation
voltage
Positive pin: ±1000 V, Negative pin: ±900 V Positive pin: ±1000 V, Negative pin: ±900 V Positive pin: ±1000 V, Negative pin: ±900 V Positive pin: ±1000 V, Negative pin: ±900 V Positive pin: ±1000 V, Negative pin: ±900 V
Minimum
operating
voltage
At the rated current: 10V
When the current begins to flow: 1.5 V or less
At the rated current: 10V
When the current begins to flow: 1.5 V or less
At the rated current: 10V
When the current begins to flow: 1.5 V or less
At the rated current: 10V
When the current begins to flow: 1.5 V or less
At the rated current: 10V
When the current begins to flow: 1.5 V or less
Constant Resistance (CR) Mode
Operating Range
H Range 500 mS to 0 S 1 S to 0 S 2 S to 0 S 6 S to 0 S 10 S to 0 S
L Range 5 mS to 0 S 10 mS to 0 S 20 mS to 0 S 60 mS to 0 S 100 mS to 0 S
Setting Range
H Range 505.00 mS to 0.00 S 1.01000 S to 0.00000 S 2.02000 S to 0.00000 S 6.0600 S to 0.00000 S 10.1000 S to 0.0000 S
L Range 5.0500 mS to 0.0000 S 10.1000 mS to 0.0000 S 20.2000 mS to 0.000 S 60.600 mS to 0.000 S 101.000 mS to 0.000 S
Resolution
H Range 0.01 mS 0.00002 S 0.00005 S 0.0002 S 0.0002 S
L Range 0.0001 mS 0.0002 mS 0.0005 mS 0.002 mS 0.002 mS
Setting Accuracy
H Range ±(0.5 % of setting + 0.5 % of rating) ±(0.5 % of setting + 0.5 % of rating) ±(0.5 % of setting + 0.5 % of rating) ±(0.5 % of setting + 0.5 % of rating) ±(0.5 % of setting + 0.5 % of rating)
L Range ±(0.5 % of setting + 0.2 % of rating) ±(0.5 % of setting + 0.2 % of rating) ±(0.5 % of setting + 0.2 % of rating) ±(0.5 % of setting + 0.2 % of rating) ±(0.5 % of setting + 0.2 % of rating)
Parallel Operation
H Range ±(1.0 % of setting + 1.0 % of rating) ±(1.0 % of setting + 1.0 % of rating) ±(1.0 % of setting + 1.0 % of rating) ±(1.0 % of setting + 1.0 % of rating) ±(1.0 % of setting + 1.0 % of rating)
L Range ±(1.0 % of setting + 0.4 % of rating) ±(1.0 % of setting + 0.4 % of rating) ±(1.0 % of setting + 0.4 % of rating) ±(1.0 % of setting + 0.4 % of rating) ±(1.0 % of setting + 0.4 % of rating)
Response Speed NORM/FAST NORM/FAST NORM/FAST NORM/FAST NORM/FAST
Constant Current (CC) Mode
Operating range 0 A to 20 A 0 A to 40 A 0 A to 80 A 0 A to 240 A 0 A to 400 A
Setting range 0.0000 A to 20.2000 A 0.000 A to 40.400 A 0.000 A to 80.800 A 0.00 A to 242.40 A 0.00 A to 404.00 A
Resolution 0.0005A 0.001A 0.002A 0.005A 0.01A
Setting accuracy ±(0.2 % of setting + 0.1 % of rating) ±(0.2 % of setting + 0.1 % of rating) ±(0.2 % of setting + 0.1 % of rating) ±(0.2 % of setting + 0.1 % of rating) ±(0.2 % of setting + 0.1 % of rating)
Parallel operation ±(0.4 % of setting + 0.2 % of rating) ±(0.4 % of setting + 0.2 % of rating) ±(0.4 % of setting + 0.2 % of rating) ±(0.4 % of setting + 0.2 % of rating) ±(0.4 % of setting + 0.2 % of rating)

Note* Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Mandatory Accessories …

Optional Accessories …