Kikusui PLZ150U DC Electronic Load 1.5-150V 0-30A
£920.00 (£1,104.00 inc VAT)
3 in stock (can be backordered)
Availability: Stock models delivered next working day (UK only) for orders placed before 16:30 (Mon - Fri)
-
UK Power Cord
Standard Hardware Accessories
Documentation
PLZ Series: How to Effectively Improve Safety during Load Testing of Non-isolated AC/DC Converter
Blown Fuse Testing Precautions When Using Electronic Load
Using Electronic Load to Battery Charger Testing
PLZ Series Easy Way to Expand Electronic Load Capacity in CV Mode
DC Electronic Load – Part 6: Application and Example (2)
DC Electronic Load – Part 2: Basic Operation Mode and Principle (1)
How to Minimise Power Supply Noise in Test Systems
Choosing Electronic Load that Best Fits Your Switch Testing System
Two Methods to Absorb Motor’s Regenerative Current Using Electronic Load
DC Electronic Load – Part 1: What is a DC Electronic Load?
How to Balance Battery Module Charge-Discharge
DC Electronic Load – Part 4: How Each Operation Mode Works with Other Modes?
PLZ-U/UA Specifications | ||
---|---|---|
Model | PLZ150U | PLZ70UA |
Ratings | ||
Operating Voltage (DC) | 1.5 V to 150 V | 0 V to 150 V |
Current/Power | ||
H | 30 A/150 W | 15 A/75 W |
M | 3 A/150 W | 1.5 A/75 W |
L | 300 mA/45 W | 150 mA/22.5 W |
Isolation voltage of the load input terminal | 500VDC | 500VDC |
Withstand voltage between load input terminal channels | 500VDC | 500VDC |
Minimum start voltage | 0.3 V or greater | 0.3 V or greater |
CC Mode | ||
Operating Range | ||
H | 0 A to 30 A | 0 A to 15 A |
M | 0 A to 3 A | 0 A to 1.5 A |
L | 0 A to 300 mA | 0 A to 150 mA |
Selectable Range | 0 % to 105 % of f.s | 0 % to 105 % of f.s |
Resolution | ||
H | 2mA | 1mA |
M | 0.2mA | 0.1mA |
L | 0.02mA | 0.01mA |
Accuracy of setting (H, M and L) | ±(0.2 % of set + 0.2 % of f.s) + Vin / 500 kΩ | ±(0.2 % of set + 0.2 % of f.s) + Vin / 500 kΩ |
Input voltage variation | ||
H | 2mA | 2mA |
M | 1mA | 1mA |
L | 0.1mA | 0.1mA |
Ripple | rms: 3mA p-p: 30mA |
rms: 3mA p-p: 30mA |
CR Mode | ||
Operating range The value inside parentheses is the conductance. |
||
H | OPEN to 50 mΩ (0 S to 20 S) | OPEN to 100 mΩ (0 S to 10 S) |
M | OPEN to 500 mΩ (0 S to 2 S) | OPEN to 1 Ω (0 S to 1 S) |
L | OPEN to 5 Ω (0 S to 200 mS) | OPEN to 10 Ω (0 S to 100 mS) |
Selectable Range | 0 % to 105 % of f.s | 0 % to 105 % of f.s |
Resolution | ||
H | 0.2 mS (0 S to 2 S)
2 mS (2 S to 20 S) |
0.1 mS (0 S to 1 S)
1 mS (1 S to 10 S) |
M | 20 μS (0 S to 200 mS) 0.2 mS (200 mS to 2 S) |
10 μS (0 S to 100 mS) 0.1 mS (100 mS to 1 S) |
L | 2 μS(0 S to 20 mS) 20 μS(20 mS to 200 mS) |
1 μS(0 S to 10 mS) 10 μS(10 mS to 100 mS) |
Accuracy of setting | ±(0.5 % of set + 0.5 % of f.s ) + Vin/500 kΩ | ±(0.5 % of set + 0.5 % of f.s ) + Vin/500 kΩ |
Note* Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.