Kikusui PBZ20-20 Bi-Polar Power Supply

The Kikusui PBZ 20-20 (+/-0 to 20V +/-0 to 20A) is a bipolar type DC regulated power source that can continuously change both + and polarities passing through 0 without changing the output terminal. By adopting a Switching + Linear system, the PBZ is able to realize both drastic weight reduction as well as high speed and low noise operation. Since operation covers 4 quadrants, power can be both supplied (source) and absorbed (sink). The PBZ can also drive inductive or capacitive loads. The unit also equips a signal generator function which enables waveform and sequence creation. The PBZ is also capable of synchronized operation which is required for voltage variation tests, and it can also be expanded for large current applications through master-slave parallel operation.

Features:

  • Sequence function (The basic sine, triangular and square waveforms, as well as the 16 user-defined waveforms, can each be set as a sequence step)
  • Parallel operation function
  • Unipolar mode (In unipolar mode it is still possible to apply current in both directions (source and sink).
  • Control via browser (”with LAN” model)
  • CV/CC selectable mode
  • Memory function
  • Protection functions (Over voltage/Over current/Over heat/ Power limit)
  • Fine setting
  • Key lock
  • Remote sensing
  • Output voltage/current monitor
  • External voltage/resistance control
  • External signal input
  • Status signal output

Product Videos

Documentation

AC Input, Rated Output
ModelPBZ20-20APBZ20-20PBZ40-10PBZ60-6.7PBZ80-5
AC Input
Nominal input voltage100 Vac to 240 Vac, 50 Hz to 60 Hz100 Vac to 240 Vac, 50 Hz to 60 Hz100 Vac to 240 Vac, 50 Hz to 60 Hz100 Vac to 240 Vac, 50 Hz to 60 Hz100 Vac to 240 Vac, 50 Hz to 60 Hz
Voltage and frequency range90 Vac to 250 Vac, 47 Hz to 63 Hz90 Vac to 250 Vac, 47 Hz to 63 Hz90 Vac to 250 Vac, 47 Hz to 63 Hz90 Vac to 250 Vac, 47 Hz to 63 Hz90 Vac to 250 Vac, 47 Hz to 63 Hz
Current10 Aac or less (when connected to a rated load)10 Aac or less (when connected to a rated load)10 Aac or less (when connected to a rated load)10 Aac or less (when connected to a rated load)10 Aac or less (when connected to a rated load)
Inrush current (1 ms or more)20 Apeak or less(input 100 V)
40 Apeak or less(input 200 V)
40 Apeak or less40 Apeak or less40 Apeak or less40 Apeak or less
Power900 VA or less (when connected to a rated load)900 VA or less (when connected to a rated load)900 VA or less (when connected to a rated load)900 VA or less (when connected to a rated load)900 VA or less (when connected to a rated load)
Power factor0.95 TYP (when the input voltage is 100 V and when connected to a rated load)0.95 TYP (when the input voltage is 100 V and when connected to a rated load)0.95 TYP (when the input voltage is 100 V and when connected to a rated load)0.95 TYP (when the input voltage is 100 V and when connected to a rated load)0.95 TYP (when the input voltage is 100 V and when connected to a rated load)
Rated Output
Output power400W400W400W402W400W
Output voltage±20 V±20 V±40 V±60 V±80 V
Output current±20 A±20 A±10 A±6.7 A±5 A
Peak current±120 Apeak (TYP)
±100 Apeak (TYP)
Isolation voltage500 Vdc, Only the output’s COM terminal can be grounded.500 Vdc, Only the output’s COM terminal can be grounded.500 Vdc, Only the output’s COM terminal can be grounded.500 Vdc, Only the output’s COM terminal can be grounded.500 Vdc, Only the output’s COM terminal can be grounded.
Constant Voltage (CV Mode)
DC Current
Bipolar mode0.000 V to ±21.000 V0.000 V to ±21.000 V0.000 V to ±42.000 V0.000 V to ±63.000 V0.000 V to ±84.000 V
Unipolar mode0.000 V to 21.000 V0.000 V to 21.000 V0.000 V to 42.000 V0.000 V to 63.000 V0.000 V to 84.000 V
Fine feature±5 % of rtg±5 % of rtg±5 % of rtg±5 % of rtg±5 % of rtg
Setting resolution0.001 V (0.0001 V for the fine feature)0.001 V (0.0001 V for the fine feature)0.001 V (0.0001 V for the fine feature)0.002 V (0.0002 V for the fine feature)0.002 V (0.0002 V for the fine feature)
Setting accuracy± (0.05 % of setting + 0.05 % of rtg)± (0.05 % of setting + 0.05 % of rtg)± (0.05 % of setting + 0.05 % of rtg)± (0.05 % of setting + 0.05 % of rtg)± (0.05 % of setting + 0.05 % of rtg)
Temperature coefficient±100 ppm/°C of rtg (TYP)±100 ppm/°C of rtg (TYP)±100 ppm/°C of rtg (TYP)±100 ppm/°C of rtg (TYP)±100 ppm/°C of rtg (TYP)
AC current
Setting range0.00 Vpp to 42.00 Vpp0.00 Vpp to 42.00 Vpp0.00 Vpp to 84.00 Vpp0.00 Vpp to 126.00 Vpp0.00 Vpp to 168.00 Vpp
Setting resolution0.01 V0.01 V0.1 V0.1 V0.1 V
Setting accuracy±0.5 % of rtg±0.5 % of rtg±0.5 % of rtg±0.5 % of rtg±0.5 % of rtg
AC frequency
Setting range0.01 Hz to 200.00 kHz0.01 Hz to 100.00 kHz0.01 Hz to 100.00 kHz0.01 Hz to 100.00 kHz0.01 Hz to 100.00 kHz
Setting resolution0.01 Hz0.01 Hz0.01 Hz0.01 Hz0.01 Hz
Setting accuracy±200 ppm±200 ppm±200 ppm±200 ppm±200 ppm
SweepLinear and logarithmicLinear and logarithmicLinear and logarithmicLinear and logarithmicLinear and logarithmic
Sweep Time100 μs to 1000 s (resolution of 100 μs)100 μs to 1000 s (resolution of 100 μs)100 μs to 1000 s (resolution of 100 μs)100 μs to 1000 s (resolution of 100 μs)100 μs to 1000 s (resolution of 100 μs)
AC waveform
TypeSine wave, square wave, triangle wave, and 16 user-defined arbitrary waveformsSine wave, square wave, triangle wave, and 16 user-defined arbitrary waveformsSine wave, square wave, triangle wave, and 16 user-defined arbitrary waveformsSine wave, square wave, triangle wave, and 16 user-defined arbitrary waveformsSine wave, square wave, triangle wave, and 16 user-defined arbitrary waveforms
Start phase0 ° to 359 °0 ° to 359 °0 ° to 359 °0 ° to 359 °0 ° to 359 °
Square wave duty cycle0.1 % to 99.9 % (f < 100 Hz), 1 % to 99 % (100 Hz ≤ f < 1 kHz), 10 % to 90 % (1 kHz ≤ f < 10 kHz), and fixed to 50 % (10 kHz < f)0.1 % to 99.9 % (f < 100 Hz), 1 % to 99 % (100 Hz ≤ f < 1 kHz), 10 % to 90 % (1 kHz ≤ f < 10 kHz), and fixed to 50 % (10 kHz < f)0.1 % to 99.9 % (f < 100 Hz), 1 % to 99 % (100 Hz ≤ f < 1 kHz), 10 % to 90 % (1 kHz ≤ f < 10 kHz), and fixed to 50 % (10 kHz < f)0.1 % to 99.9 % (f < 100 Hz), 1 % to 99 % (100 Hz ≤ f < 1 kHz), 10 % to 90 % (1 kHz ≤ f < 10 kHz), and fixed to 50 % (10 kHz < f)0.1 % to 99.9 % (f < 100 Hz), 1 % to 99 % (100 Hz ≤ f < 1 kHz), 10 % to 90 % (1 kHz ≤ f < 10 kHz), and fixed to 50 % (10 kHz < f)
Constant
current
characteristics
Frequency responseDC to 150 kHz (TYP)DC to 100 kHz (TYP)DC to 100 kHz (TYP)DC to 100 kHz (TYP)DC to 100 kHz (TYP)
Response2.3 μs, 6.7 μs, 23 μs, 67 μs (TYP)3.5 μs, 10 μs, 35 μs, 100 μs (TYP)3.5 μs, 10 μs, 35 μs, 100 μs (TYP)3.5 μs, 10 μs, 35 μs, 100 μs (TYP)3.5 μs, 10 μs, 35 μs, 100 μs (TYP)
Overshoot5 % or less (TYP)5 % or less (TYP)5 % or less (TYP)5 % or less (TYP)5 % or less (TYP)
Ripple noise (rms)p-p: 20 mV (TYP)
rms: 2 mV (TYP)
p-p: 20 mV (TYP)
rms: 2 mV (TYP)
p-p: 20 mV (TYP)
rms: 4 mV (TYP)
p-p: 30 mV (TYP)
rms: 4 mV (TYP)
p-p: 30 mV (TYP)
rms: 4 mV (TYP)
Load effect±(0.005 % of setting + 1 mV)±(0.005 % of setting + 1 mV)±(0.005 % of setting + 1 mV)±(0.005 % of setting + 1 mV)±(0.005 % of setting + 1 mV)
Source effect±(0.005 % of setting + 1 mV)±(0.005 % of setting + 1 mV)±(0.005 % of setting + 1 mV)±(0.005 % of setting + 1 mV)±(0.005 % of setting + 1 mV)

Note* Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.

1 review for Kikusui PBZ20-20 Bipolar DC Power Supplies +/- 0 -20V +/- 0-20A

  1. Jeff B

    Found the guys a Telonic very helpful when searching for a high speed power supply