Tekbox TBBCI1-300K420 Snap-On Bulk Current Injection Probe

£1419.00 (£1702.80 inc. VAT)

Available on back-order

Description


TBBCI1-300K420 Snap-On Bulk Current Injection Probe

The TBBCI1-300K420-HV snap-on Bulk Current Injection probe can be used up to 400 MHz.

The BCI probe can be used for ISO11452-4 BCI testing, GJB 151B, CS114 testing for MILSTD 461G and DO160 section 20 testing. The probe also complies with DO-160 Section 22, the pulse-induced damped sinusoidal test for 5 kV pulse injection.

The insertion loss is 5 dB for most of its bandwidth. The probe is individually characterised and usable in the frequency range 10 kHz – 450 MHz. The probe can be used to inject severity levels I (60mA), II (100mA, III (150mA), IV (200mA) and customer-specific severity level V up to 350 mA.

The probe can also be used for RF current monitoring applications.

The aperture of the RF current monitoring probe is 27 mm. The typical insertion loss is 5 dB, and the typical transfer impedance is 26 dB Ohm.

Short Spec
  • Compliance: ISO 11452-4; MIL-STD-461 CS114, GJB 151B-2013, DO-160
  • Characterised freq. range: 10 kHz to 500 MHz
  • Insertion loss: 5 dB typ.; 50 Ohm system (100 Ohm loop impedance)
  • Transfer impedance: 29 dB Ohm typ.; 50 Ohm system (100 Ohm loop impedance)
  • Power rating: capable of injecting severity levels I, II, III, IV according to ISO 11452 and customer-specified level V up to 350 mA
  • Max. core temperature: 80 °C
  • Connector type: BNC-SHV
  • male Aperture diameter: 27 mm
  • Outside diameter: 92 mm
  • Height: 76 mm
  • Weight: 1.2 kg
Applications/ Standards

Automotive EMC Testing

  • ISO 11452-4 BCI testing on wiring harnesses and signal/power lines
  • Immunity validation of ECUs, ADAS, infotainment, and body electronics

Military & Aerospace EMC Testing

  • MIL-STD-461G CS114 and GJB 151B conducted susceptibility testing
  • RTCA DO-160 Section 20
  • Suitable for avionics, defence electronics, and mission-critical systems

RF Current Monitoring & Diagnostics

  • Non-intrusive RF current measurement on cables and harnesses
  • Verification of injected current during BCI testing
  • EMC troubleshooting

EMC Pre-Compliance & R&D

  • Early-stage immunity testing prior to formal certification
  • Ideal for development labs and EMC engineering environments

Documentation

Compliance: ISO 11452-4; MIL-STD-461 CS114, GJB 151B-2013, DO-160
Characterised freq. range: 10 kHz to 500 MHz
Insertion loss: 5 dB typ.; 50 Ohm system (100 Ohm loop impedance)
Transfer impedance: 29 dB Ohm typ.; 50 Ohm system (100 Ohm loop impedance)
Power rating: capable of injecting severity levels I, II, III, IV according to ISO 11452 and customer-specified level V up to 350 mA
Max. core temperature: 80 °C
Connector type: BNC-SHV
Male Aperture diameter: 27 mm
Outside diameter: 92 mm
Height: 76 mm
Weight: 1.2 kg