Free Shipping logo FREE SHIPPING £75+
50 years of Telonic Instruments Ltd logo CELEBRATING 50+ YEARS
Price Match logo PRICE MATCH GUARANTEE

Archive for June, 2021

DC Electronic Load – Part 6: Application and Example (2)

DC Electronic Load – Part 6: Application and Example (2)

Continuing from the previous white paper, here are three more effective applications and examples of electronic loads. 6-1. Applying the Load to a Motor Figure 6-1 shows a block diagram illustrating an example of the DC motor test system. In this system, the test motor (DUT) is driven by the DC power supply. The coupling is connected to the DUT and another motor in order to app...
DC Electronic Load – Part 6: Application and Example (2)

Single-phase Three-wire Output from One AC Power Supply

A single-phase three-wire output can be achieved usually by connecting two AC power supplies. However, if you need to output from one AC power supply and the required current through DUT is small, you can output it by configuring the following circuit. 1. Single-phase Three-wire System In the figure below, R1=R2. Appropriate resistance for power supply should be applied on R1 an...
DC Electronic Load – Part 6: Application and Example (2)

What It Takes to Keep Regulated DC Power Supply Stable Part 1: Connecting Cable

A regulated DC power supply (referred as DC power supply) is an electrical device to convert AC into a constant DC. Its function is to maintain a constant output voltage, however, unfortunately even if you use an intelligent DC power supply, improper wiring can mess up a whole system operation or performance. In this white paper, we explain the best practices for connecting a power cable and load...

Switching Function Improvement in PLZ5W Series

PLZ5W Series features a switching current function to repetitively fluctuate between two current levels, and this function has been improved as compared with the previous model of PLZ4W Series for the following characteristics: 1) Switching speed 2) Switching waveform quality * In PLZ4W Series, the switching speed tends to become slow when connecting a resistance load. Here you will find th...
DC Electronic Load – Part 6: Application and Example (2)

When to use the LPF Setting TOS9300 Series

The TOS9300 series of electrical safety testers is a robust all-in-one solution. When performing AC Hipot, DC Hipot and Insulation Resistance tests there are setting options which allow the user to optimise testing as necessary for all applications. In certain situations whe...
DC Electronic Load – Part 6: Application and Example (2)

Using Bipolar Power Supply PBZ Series as AC Electronic Load

In this white paper, we are going to share the techniques to make the system that our bipolar power supply PBZ Series acts as a constant resistance load. 1. System Details First, we are describing the system. See Figure 1 below; two units of ...
DC Electronic Load – Part 6: Application and Example (2)

Output On/Off Behaviour of PBZ Series

For PBZ Series, a magnetic relay is used to turn the output on/off. The relay is off to turn the output off; when the output is off, the output is in the high impedance state. In addition, if the output-on/off is controlled by an external signal input, the embed...
DC Electronic Load – Part 6: Application and Example (2)

Precautions When Operating AC Power Supply ‘PCR-LE Series’ in DC Mode

PCR-LE/LE2 Series can produce a DC output that enables you to test DC-powered devices such as DC-input converters. This article introduces the important precautions and useful functions to effectively operate PCR-LE/LE2 Series in DC mode. 1. Circuit Model See Figure 1 for the test circuit model with PCR-LE. It illustrates the DC-input converter/inverter that has a capacitor-i...
DC Electronic Load – Part 6: Application and Example (2)

Output Connection Methods with Parallel Control

Parallel operation is very useful to expand an output capacity; especially master-slave parallel operation allows you to control an entire system by one master unit. When making the master-slave connection such as signal wiring and load connection, you may find some issues with load connection. Improper connection may cause oscillation so that our user’s manual describes how to connect the load...
DC Electronic Load – Part 6: Application and Example (2)

Operation Tutorial to Perform Simulated CC Operation in PCR-LE Series

1. Overview In PCR-LE Series, simulated CC operation can be achieved by setting the current limit in AC mode. This method is based on its internal system as the ammeter monitors the output current and the arithmetic circuit controls the output voltage. The functions and characteristics of thi...
DC Electronic Load – Part 6: Application and Example (2)

PLZ Series Easy Way to Expand Electronic Load Capacity in CV Mode

PLZ Series Easy Way to Expand Electronic Load Capacity in CV Mode Our electronic load PLZ Series has a well-known feature that a master/slave parallel operation expands an output capacity in the same model, controlled slave units by a master unit (except for PLZ-4WL). In this article, we are going to further explain how to increase the capacity by parallel connection with d...
DC Electronic Load – Part 6: Application and Example (2)

Using Electronic Load to Battery Charger Testing

Using Electronic Load to Battery Charger Testing A battery charger is a device that can recharge a secondary cell or rechargeable battery. Every battery charger being used requires the testing and such testing system must include something to simulate a battery. An electronic load can provide the best solution for the battery charger testing to simulate the actual behaviour o...

Sub Categories

AC Power Supplies / Frequency Converters Offers & Promotions (1)

Application Notes

Blog (97)

DC Power Supplies Offers & Promotions (6)

Digital Multimeters Offers & Promotions (1)

Digital Oscilloscopes Offers & Promotions (5)

Electronic Loads Offers & Promotions (1)

Events (7)

Knowledge Base AC Power Supplies

Knowledge Base Data Acquisition Systems

Knowledge Base DC Power Supplies

Knowledge Base DG1000 Series (14)

Knowledge Base DG4000 Series (14)

Knowledge Base Digital Multimeters

Knowledge Base Digital Oscilloscopes

Knowledge Base DL3000 Series (2)

Knowledge Base DM3000 Series (21)

Knowledge Base DP700 Series (8)

Knowledge Base DP800 Series (26)

Knowledge Base DS1000 Series (46)

Knowledge Base DS2000 Series (36)

Knowledge Base DSA800 Series (70)

Knowledge Base DSG800 Series (2)

Knowledge Base Electrical Safety Analysers

Knowledge Base Electronic Loads

Knowledge Base M300 Series (2)

Knowledge Base MSO/DS7000 Series (35)

Knowledge Base MSO5000 Series (35)

Knowledge Base MSO8000 Series (32)

Knowledge Base PBZ Series (3)

Knowledge Base PCR-LE Series (3)

Knowledge Base PCR-MA Series (3)

Knowledge Base PCR-WE/WE2 Series (3)

Knowledge Base PLZ-5W Series (3)

Knowledge Base PLZ-5WH Series (3)

Knowledge Base PLZ-5WH2 Series (3)

Knowledge Base PMX-Multi Series (3)

Knowledge Base PWR-01 Series (3)

Knowledge Base RF Signal Generators

Knowledge Base RSA3000 Series (32)

Knowledge Base RSA5000 Series (31)

Knowledge Base SDG1000X Series (10)

Knowledge Base SDG2000X Series (11)

Knowledge Base SDG6000X Series (11)

Knowledge Base SDG800 Series (10)

Knowledge Base SDL1000X Series (5)

Knowledge Base SDM3000 Series (6)

Knowledge Base SDS1000X-E Series (15)

Knowledge Base SDS2000X-E Series (15)

Knowledge Base SDS5000X Series (15)

Knowledge Base SPD1000X (5)

Knowledge Base SPD3000X/X-E Series (6)

Knowledge Base Spectrum Analysers

Knowledge Base SSA3000X Plus Series (2)

Knowledge Base SSA3000X Series (15)

Knowledge Base SSA3000X-R Series (1)

Knowledge Base SSG3000X Series (4)

Knowledge Base SVA1000X Series (13)

Knowledge Base TOS9300 Series (3)

Knowledge Base Waveform Generators

LCR Meters Offers & Promotions (1)

Product Support (1)

RF Signal Generators (1)

Safety Testers Offers & Promotions (1)

Spectrum Analysers Offers & Promotions (4)

Telonic Instruments News (19)

Telonic Offers & Promotions (8)

CLICK TO CALL

0118 9786911
CLICK TO EMAIL