Two Methods to Absorb Motor’s Regenerative Current Using Electronic Load

Two Methods to Absorb Motor’s Regenerative Current Using Electronic Load

There are two methods to absorb motor’s regenerative current; Voltage Clipping Method and Bleeder Method. The following describes the characteristics, functions and precaution for the methods. Fig.1 illustrates the typical test system. 1...
Two Methods to Absorb Motor’s Regenerative Current Using Electronic Load

Choosing Electronic Load that Best Fits Your Switch Testing System

The switch on/off testing can be performed with a combination of DC power supply and electronic load (See Figure 1). To successfully conduct the testing, it is important to know that the current flow through the switch varies by the electronic load specifications or settings. Especially during the life testing, you should be aware that it may affect the lifetime of test switch. This white paper s...
Two Methods to Absorb Motor’s Regenerative Current Using Electronic Load

How to use the power line disturbance simulation function of PCR-WE

Voltage dips, short interruptions and voltage variations immunity tests of the IEC 61000-4-11 standard can be easily tested using the power line disturbance simulation function of PCR-WE. As an example, it explains how to set the voltage dip test. You can easily execute tests under the test conditions specified in the standard in a few steps. ...
Two Methods to Absorb Motor’s Regenerative Current Using Electronic Load

How Does Surge Suppression Work in PCR-LE/LE2 Series?

PCR-LE/LE2 Series feature the Surge Suppression function that involves the process of protecting PCR-LE/LE2 from voltage spike. You can choose Surge Suppression to turn on or off depending on your load condition. If you want to avoid any voltage overshooting or undershooting, always set Surge Suppression to on. However, when you use a load with regenerative feedback (e.g. capacitive load or batte...
Two Methods to Absorb Motor’s Regenerative Current Using Electronic Load

Necessity of Grounding Output Terminal for DC/AC Power Supply

Power supply has the following three output terminals: - DC power supply: Positive/negative terminals and Ground (GND) terminal - AC power supply: L/N terminals and GND terminal. Upon using both power supplies, it is necessary to determine whether either of positive or negative terminals or L/N terminals is connected to the GND terminal. As our factory default; - DC power supply: Depending on ...
Two Methods to Absorb Motor’s Regenerative Current Using Electronic Load

How to Minimise Power Supply Noise in Test Systems

Noise is an unwanted but inevitable problem in test systems including power supply sources, except batteries, which are low-noise power sources. Some amount of noise is always generated or relayed by power supplies; however, a power supply is a device that supplies power to another device, and not intended to be used by itself. Power supply noise should be low enough so as not to interfere with th...
Two Methods to Absorb Motor’s Regenerative Current Using Electronic Load

DC Electronic Load – Part 2: Basic Operation Mode and Principle (1)

As described in Part 1, electronic loads can act as a variable resistor and regulate a current depending on your applications. With this function, electronic loads can be used as substitute for high-power components. To fulfill this function and test DUTs effectively, there are four operation modes for electronic loads: 1) constant current 2) constant resistance 3) constant voltage and 4) constant...
Two Methods to Absorb Motor’s Regenerative Current Using Electronic Load

What Makes a Good Power Supply?

DC or AC regulated power supplies (hereinafter called ‘power supply’) can be classified into eight types and four categories in accordance with the output source (DC or AC), output range, polarity or circuit method as shown in Table 1. In this...
Two Methods to Absorb Motor’s Regenerative Current Using Electronic Load

What It Takes to Keep Regulated DC Power Supply Stable Part 2: Load Conditions

Basically, a regulated DC power supply (referred as DC power supply) is an electrical device that provides a constant output voltage; however, sometimes it cannot remain stable. There might be some factors that affect the stability of the DC power supply, and Part 1 previously focused on one of them: how you connect cables on a system. Here in Part 2, we look at one other important factor that nee...
Two Methods to Absorb Motor’s Regenerative Current Using Electronic Load

How to Select a Right DC Power Supply Part 2: Key Considerations

Welcome back to Part 2 of this series! Part 1 is all about the functions and characteristics of DC power supplies. In Part 2 here, we will take a look at the considerations when selecting a right power supply. 1. Key Considerations There are too many considerations when selecting a DC power supply. This makes it hard to select a right power supply without any understanding, whic...
Two Methods to Absorb Motor’s Regenerative Current Using Electronic Load

Voltage Interruption Waveforms Provided by PCR-LE Series

In an AC circuit, power supply interruption can be mainly divided into two types: it occurs with low impedance or with high impedance. The power supply interruption with low impedance is a short-circuit interruption. A short circuit is an unintended path to flow a current with typically very low impedance. Whereas, the power supply interruption with high impedance is an open-circuit interruption....
Two Methods to Absorb Motor’s Regenerative Current Using Electronic Load

How to Reduce Power Supply Noise

In a test system, AC power supply is one of the significant components that can create test sequences for output and supply source to DUT. However, the power supply may cause a noise issue during test. There is some noise interference such as conducted noise and magnetic field that may enter into the test system. This article focuses on a noise terminal voltage at an input and output terminal whi...

Sub Categories

AC Power Supplies / Frequency Converters Offers & Promotions (1)

Application Notes

Blog (97)

DC Power Supplies Offers & Promotions (6)

Digital Multimeters Offers & Promotions (1)

Digital Oscilloscopes Offers & Promotions (5)

Electronic Loads Offers & Promotions (1)

Events (7)

Knowledge Base AC Power Supplies

Knowledge Base Data Acquisition Systems

Knowledge Base DC Power Supplies

Knowledge Base DG1000 Series (14)

Knowledge Base DG4000 Series (14)

Knowledge Base Digital Multimeters

Knowledge Base Digital Oscilloscopes

Knowledge Base DL3000 Series (2)

Knowledge Base DM3000 Series (21)

Knowledge Base DP700 Series (8)

Knowledge Base DP800 Series (26)

Knowledge Base DS1000 Series (46)

Knowledge Base DS2000 Series (36)

Knowledge Base DSA800 Series (70)

Knowledge Base DSG800 Series (2)

Knowledge Base Electrical Safety Analysers

Knowledge Base Electronic Loads

Knowledge Base M300 Series (2)

Knowledge Base MSO/DS7000 Series (35)

Knowledge Base MSO5000 Series (35)

Knowledge Base MSO8000 Series (32)

Knowledge Base PBZ Series (3)

Knowledge Base PCR-LE Series (3)

Knowledge Base PCR-MA Series (3)

Knowledge Base PCR-WE/WE2 Series (3)

Knowledge Base PLZ-5W Series (3)

Knowledge Base PLZ-5WH Series (3)

Knowledge Base PLZ-5WH2 Series (3)

Knowledge Base PMX-Multi Series (3)

Knowledge Base PWR-01 Series (3)

Knowledge Base RF Signal Generators

Knowledge Base RSA3000 Series (32)

Knowledge Base RSA5000 Series (31)

Knowledge Base SDG1000X Series (10)

Knowledge Base SDG2000X Series (11)

Knowledge Base SDG6000X Series (11)

Knowledge Base SDG800 Series (10)

Knowledge Base SDL1000X Series (5)

Knowledge Base SDM3000 Series (6)

Knowledge Base SDS1000X-E Series (15)

Knowledge Base SDS2000X-E Series (15)

Knowledge Base SDS5000X Series (15)

Knowledge Base SPD1000X (5)

Knowledge Base SPD3000X/X-E Series (6)

Knowledge Base Spectrum Analysers

Knowledge Base SSA3000X Plus Series (2)

Knowledge Base SSA3000X Series (15)

Knowledge Base SSA3000X-R Series (1)

Knowledge Base SSG3000X Series (4)

Knowledge Base SVA1000X Series (13)

Knowledge Base TOS9300 Series (3)

Knowledge Base Waveform Generators

LCR Meters Offers & Promotions (1)

Product Support (1)

RF Signal Generators (1)

Safety Testers Offers & Promotions (1)

Spectrum Analysers Offers & Promotions (4)

Telonic Instruments News (19)

Telonic Offers & Promotions (8)

CLICK TO CALL

0118 9786911
CLICK TO EMAIL