Siglent SVA1032X Spectrum / Vector Network Analyser

The SVA1032X is a Spectrum and Vector Network Analyser with a Frequency Range up to 3.2GHz. The SIGLENT SVA1000X series spectrum & vector network analysers are powerful and flexible tools for RF signal and network analysis. With a frequency range to 3.2 GHz, the analyser delivers reliable automatic measurements and multiple modes of operation: the base model are a spectrum analyser and a vector network analyser, optional functions include a distance-to-fault locator, a vector signal analyser. Applications include broadcast monitoring/evaluation, site surveying, S-parameter measurement, cable and antenna testing, analogue/digital modulation analysis, EMI pre-compliance test, research and development, education, production, and maintenance.

Purchase of SVA mechanical calibration kit recommended for VNA use.

  • Tracking Generator Standard
  • Distance To Fault (Opt.)
  • Vector Network Analysis (Std.)
  • Vector Signal Modulation Analysis (Opt.)
  • EMI Filter and Quasi-Peak Detector Kit (Opt.)
  • Advanced Measurement Kit (Opt.)
  • 10.1 lnch Multi-Touch Screen , Mouse and Keyboard supported
  • Web Browser Remote Control on PC and Mobile Terminals and File Operation

Siglent SVA1000X Spectrum/Vector Network Analyser Comparison Table

ModelFrequency RangeResolution Bandwidth (RBW)Phase NoiseTotal Amplitude AccuracyDisplay Average Noise Level (DANL)
SVA1015X9kHz to 1.5GHz1Hz to 1MHz<- 99dBc/Hz≤1.2dB-156dBm/Hz
SVA1032X9kHz to 3.2GHz1Hz to 1MHz<- 99dBc/Hz≤0.7dB-161dBm/Hz
SVA1075X9kHz to 7.5GHz1Hz to 1MHz<- 99dBc/Hz≤0.7dB-165dBm/Hz

Product Videos

Documentation

Frequency
Frequency RangeSVA1015X: 9 kHz ~ 1.5GHz
SVA1032X: 9 kHz ~ 3.2GHz
SVA1075X: 9 kHz ~ 7.5GHz
Frequency Resolution 1 Hz
Frequency Span
Range0 Hz, 100 Hz to Max Frequency
Accuracy± Span / (number of display points – 1)
Internal Reference Source
Reference frequency10.000000 MHz
Reference frequency
accuracy / uncertainty
± [(time since last adjustment × frequency aging rate) + temperature
stability + initial calibration accuracy]
Initial calibration accuracy<1 ppm
Temperature stability<1 ppm/year, 0 °C ~50 °C
Frequency aging rate<0.5 ppm/first year, 3.0 ppm/20 years
Marker
Marker resolutionSpan / (number of display points – 1)
Marker uncertainty± [frequency indication × reference frequency uncertainty + 10% ×
resolution bandwidth + ½ * marker resolution + 1 Hz]
Frequency Counter resolutionSVA1015X: 0.01 Hz
SVA1032X: 0.01 Hz
SVA1075X: 0.1 Hz
Bandwidths
Resolution bandwidth (-3dB)SVA1015X: 1 Hz ~ 1 MHz, in 1-3-10 sequence
SVA1032X: 1 Hz ~ 1 MHz, in 1-3-10 sequence
SVA1075X: 1 Hz~3 MHz
Resolution filter shape factor< 4.8 : 1 (60 dB:3 dB), Gaussian-like
RBW uncertainty<5%
Video bandwidth (-3dB)SVA1015X: 1 Hz ~ 3 MHz, in 1-3-10 sequence
SVA1032X: 1 Hz ~ 3 MHz, in 1-3-10 sequence
SVA1075X: 1 Hz~10 MHz
VBW uncertainty<5%
Sweep and Trigger
Sweep timeSVA1015X: 1ms to 1500s
SVA1032X: 1ms to 3200s
SVA1075X: 1ms to 7500s
RBWSweep 30 Hz ~ 1 MHz; 30 Hz ~ 1 MHz; 3 kHz ~ 3 MHz
FFT 1 Hz ~ 10 kHz; 1 Hz ~ 10 kHz; 1 Hz ~ 10 kHz
Sweep ruleSingle, Continuous
Trigger sourceFree, Video, External
External trigger5V TTL level, Rising edge/Falling edge
Amplitude and Level
Measurement rangeDANL to +10 dBm, 100 kHz ~ 1 MHz, Preamp off
DANL to +20 dBm, 1 MHz ~ 7.5 GHz, Preamp off
Reference level-200 dBm to +30 dBm, 1 dB steps
Preamplifier20 dB (nom.)
Input attenuation0 ~ 30 dB, 1 dB steps, 0 ~ 50 dB, 1 dB steps
Maximum input DC voltage+/- 50 VDC
Maximum average power30 dBm, 3 minutes, fc ≥10 MHz, att > 20 dBm, preamp off
Maximum damage level33 dBm, fc ≥ 10 MHz, att > 20 dBm, preamp off
Level Display
Logarithmic level axis1 dB to 200 dB
Linear level axis0 to reference level
Units of level axisdBm, dBmV, dBμV, dBμA, Volt, Watt
Number of display points751
Number of traces4
Trace detectorsPositive-peak, Negative-peak, Sample, Normal,
Average(Voltage/RMS/Video), Quasi-peak
Trace functionsClear write, Max Hold, Min Hold, View, Blank, Average, Math
General Specifications
SourceAC voltage range: 100-240 V, 50/60 Hz or 100-120 V 400 Hz;
Power consumptionSVA1015X: 35W
SVA1032X: 35W
SVA1075X: 70W
TemperatureWorking temperature: 0 °C to 40 °C,
Storage temperature: -20 °C to 70 °C
Humidity0 °C to 30 °C, ≤ 95% Relative humidity
30 °C to 50 °C, ≤ 75% Relative humidity
AltitudeOperating: less than 3 km
DisplayTFT LCD, 1024 × 600, 10.1 inch multi-touch screen
StorageInternal (Flash) 256 MB, external (USB storage device) 32 GByte
Dimensions393 mm × 207 mm × 116.5 mm (W× H× D)
WeightSVA1015X: Net:  4.30 kg (9.5 lb); Shipping: 5.10 kg
SVA1032X: Net: 4.40 kg (9.7 lb); Shipping: 5.20 kg
SVA1075X: Net:  4.70 kg (10.4 lb); Shipping: 5.50 kg

Note*

Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.

1 review for Siglent SVA1032X 9kHz to 3.2GHz Spectrum / Vector Network Analyser + FREE VNA & TG Licence

  1. Ben H

    Ordered my new VNA at 12:30, tuning my antenna by 10:30 the next day

Only logged in customers who have purchased this product may leave a review.

Optional Accessories …