Kikusui PWX750HF DC Power Supply (Old Stock One Year Warranty)

The Kikusui PWX750HF is a 0-650V 0-3.5A (750W max) CV/CC programmable regulated DC power supply designed to be optimised for a rack-mounted power supply. To increase its mounting efficiency, 19-inch rack width which is only 1U high with cooling running from the front to the back which means units can be stacked on top of each other. The PWX750HF is equipped standard with USB, RS-232C, and LAN interfaces, which are essential for system integration. The PWX750HF also has a virtual multi-channel bus (VMCB) function that allows it to be used efficiently for many different remote control and monitoring architectures. In particular, the LAN interface is LXI compliant*, enabling you to control and monitor the power supply easily from a browser on a PC, smartphone, or tablet. You can also manage the power supply in a different building.

Features:

  • A wide range of voltage and current settings can be combined within its output power rating (3 times)
  • PFC circuit of 0.99 (with 100 V) or 0.97 (with 200 V) at full load *TYP value
  • Universal input voltage (85 V to 265 V)
  • LAN (LXI compliant) /USB/RS-232C fitted as standard
  • A virtual multi-channel bus (VMCB) function makes multi-channel operation more efficient
  • Emulation setting, Command language setting function
  • Expandable output capacity (parallel operation)
  • External analogue control function (Output control based on voltage and resistance; ON/OFF based on contact signals)
  • Analogue monitor output (output voltage, output current, and operating mode can be monitored)
  • Various protection functions: overvoltage protection, overcurrent protection, and overheat protection
  • Memory function (3 combinations of settings for voltage, current, OVP, OCP, and UVL)
  • Remote sensing function
  • Bleeder circuit ON/OFF setting (to prevent over-discharging of batteries)
  • CV, CC priority start function (prevents overshoot with output ON)Variable Internal Resistance Feature (Factory option *Exclude PWX750ML)

Product Videos

Documentation

AC Input, Rated Output
ModelPWX750LFPWX750MLFPWX750MHFPWX750HF
AC Input
Nominal Input Rating100 Vac to 240 Vac, 50 Hz to 60 Hz, single phase100 Vac to 240 Vac, 50 Hz to 60 Hz, single phase100 Vac to 240 Vac, 50 Hz to 60 Hz, single phase100 Vac to 240 Vac, 50 Hz to 60 Hz, single phase
Input Voltage Range85 Vac to 265 Vac85 Vac to 265 Vac85 Vac to 265 Vac85 Vac to 265 Vac
Input Frequency Range47 Hz to 63 Hz47 Hz to 63 Hz47 Hz to 63 Hz47 Hz to 63 Hz
Current (MAX)
100Vac10.5 A10.5 A10.5 A10.5 A
200Vac5.25 A5.25 A5.25 A5.25 A
Inrush Current70 A or less70 A or less70 A or less70 A or less
Power (MAX)1100 VA1100 VA1100 VA1100 VA
Power Factor (TYP)0.99 (input voltage 100 V), 0.97 (input voltage 200 V)0.99 (input voltage 100 V), 0.97 (input voltage 200 V)0.99 (input voltage 100 V), 0.97 (input voltage 200 V)0.98 (input voltage 100 V),
0.96 (input voltage 200 V)
Efficiency74 % or greater74 % or greater74 % or greater74 % or greater
Hold-up time for power interruption20 ms or greater20 ms or greater20 ms or greater20 ms or greater
Output
Rating
Output Voltage30V80V230V650V
Output Current75A28A10A3.5A
Output Power750W750W750W750W
Voltage
Setting range0 V to 31.5 V0 V to 84 V0 V to 241.5 V0 V to 682.5 V
Setting accuracy± (0.05 % of set +0.05 % of rating)± (0.05 % of set +0.05 % of rating)± (0.05 % of set +0.05 % of rating)± (0.05 % of set +0.05 % of rating)
Line regulation± 5 mV± 10 mV± 25 mV± 67 mV
Load regulation± 5 mV± 10 mV± 25 mV± 67 mV
Transient response1 ms or less1 ms or less7 ms or less7 ms or less
Ripple noisep-p: 60mV
rms: 8mV
p-p: 80mV
rms: 8mV
p-p: 120mV
rms: 25mV
p-p: 330mV
rms: 60mV
Rise timeRated Load: 100 ms
No Load: 100 ms
Rated Load: 100 ms
No Load: 100 ms
Rated Load: 100 ms
No Load: 100 ms
Rated Load: 100 ms
No Load: 100 ms
Fall timeRated Load: 100ms
No Load: 450ms
Rated Load: 100ms
No Load: 550ms
Rated Load: 150ms
No Load: 1500ms
Rated Load: 250ms
No Load: 3000ms
Maximum remote sensing compensation voltage (single line)1.5V4V5V5V
Temperature coefficient (MAX)100 ppm/°C (during external control)100 ppm/°C (during external control)100 ppm/°C (during external control)100 ppm/°C (during external control)
Current
Setting range0 A to 78.75 A0 A to 29.4 A0 A to 10.5 A0 A to 3.675 A
Setting accuracy±(0.5 % of set +0.1 % of rating)±(0.5 % of set +0.1 % of rating)±(0.5 % of set +0.1 % of rating)±(0.5 % of set +0.1 % of rating)
Line regulation± 9.5 mA± 4.8 mA± 3 mA± 2.35 mA
Load regulation± 20 mA± 10.6 mA± 7 mA± 5.7 mA
Ripple Noise (rms)150 mA65 mA30 mA15 mA
Temperature Coefficient (TYP)100 ppm/°C100 ppm/°C100 ppm/°C100 ppm/°C

Note* Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.