Model |
PMX18-2A |
PMX18-5A |
PMX35-1A |
PMX35-3A |
PMX70-1A |
PMX110-0.6A |
PMX250-0.25 |
PMX350-0.2A |
PMX500-0.1A |
EU/GB Models Input Rating |
234Vac, 50 Hz / 60 Hz, single phase |
234Vac, 50 Hz / 60 Hz, single phase |
234Vac, 50 Hz / 60 Hz, single phase |
234Vac, 50 Hz / 60 Hz, single phase |
234Vac, 50 Hz / 60 Hz, single phase |
234Vac, 50 Hz / 60 Hz, single phase |
234Vac, 50 Hz / 60 Hz, single phase |
234Vac, 50 Hz / 60 Hz, single phase |
234Vac, 50 Hz / 60 Hz, single phase |
Input voltage range |
± 10 % |
± 10 % |
± 10 % |
± 10 % |
± 10 % |
± 10 % |
± 10 % |
± 10 % |
± 10 % |
Input frequency range |
47 Hz to 63 Hz |
47 Hz to 63 Hz |
47 Hz to 63 Hz |
47 Hz to 63 Hz |
47 Hz to 63 Hz |
47 Hz to 63 Hz |
47 Hz to 63 Hz |
47 Hz to 63 Hz |
47 Hz to 63 Hz |
Power (MAX) |
150VA |
310VA |
150VA |
310VA |
230VA |
210VA |
210VA |
230VA |
170VA |
Output |
|
|
|
|
|
|
|
|
|
Rating |
|
|
|
|
|
|
|
|
|
Output voltage |
18.00V |
18.00V |
35.00V |
35.00V |
70.00V |
110.0V |
250.0V |
350.0V |
500.0V |
Output current |
2.000A |
5.000A |
1.000A |
3.000A |
1.000A |
0.600A |
0.250A |
0.200A |
0.100A |
Output power |
36W |
90W |
35W |
105W |
70W |
66W |
62.5W |
70W |
50W |
Voltage |
|
|
|
|
|
|
|
|
|
Setting range |
0 V to 18.90 V |
0 V to 18.90 V |
0 V to 36.75 V |
0 V to 36.75 V |
0 V to 73.5 V |
0 V to 115.5 V |
0 V to 262.5 V |
0 V to 367.5 V |
0 V to 525.0 V |
Setting resolution |
1 mV |
1 mV |
1 mV |
1 mV |
2 mV |
10mV |
10mV |
10mV |
10mV |
Setting accuracy |
± (0.2 % of setting +0.1 % of rating) |
± (0.2 % of setting +0.1 % of rating) |
± (0.2 % of setting +0.1 % of rating) |
± (0.2 % of setting +0.1 % of rating) |
± (0.2 % of setting +0.1 % of rating) |
± (0.2 % of setting +0.1 % of rating) |
± (0.2 % of setting +0.1 % of rating) |
± (0.2 % of setting +0.1 % of rating) |
± (0.2 % of setting +0.1 % of rating) |
Line regulation |
±1 mV |
±1 mV |
±3 mV |
±3 mV |
±5 mV |
±7 mV |
±15 mV |
±25 mV |
±30 mV |
Load regulation |
±2 mV |
±5 mV |
±3 mV |
±4 mV |
±5 mV |
±7 mV |
±15 mV |
±25 mV |
±30 mV |
Transient response |
50 μs |
50 μs |
50 μs |
50 μs |
100 μs |
100 μs |
100 μs |
100 μs |
100 μs |
Ripple noise (rms) |
0.5 mV |
0.5 mV |
0.5 mV |
0.5 mV |
1mV |
2mV |
3mV |
5mV |
10mV |
Rise time |
Rated Load: 120 ms or less
No Load: 120 ms or less |
Rated Load: 120 ms or less
No Load: 120 ms or less |
Rated Load: 120 ms or less
No Load: 120 ms or less |
Rated Load: 120 ms or less
No Load: 120 ms or less |
Rated Load: 150 ms or less
No Load: 150 ms or less |
Rated Load: 120 ms or less
No Load: 120 ms or less |
Rated Load: 120 ms or less
No Load: 120 ms or less |
Rated Load: 150 ms or less
No Load: 150 ms or less |
Rated Load: 120 ms or less
No Load: 120 ms or less |
Fall time |
Rated Load: 50 ms or less
No Load: 270 ms or less |
Rated Load: 50 ms or less
No Load: 320 ms or less |
Rated Load: 50 ms or less
No Load: 270 ms or less |
Rated Load: 50 ms or less
No Load: 270 ms or less |
Rated Load: 50 ms or less
No Load: 270 ms or less |
Rated Load: 50 ms or less
No Load: 120 ms or less |
Rated Load: 50 ms or less
No Load: 120 ms or less |
Rated Load:80 ms or less
No Load: 220 ms or less |
Rated Load: 50 ms or less
No Load: 60 ms or less |
Maximum remote sensing
compensation voltage(single line) |
0.6 V |
0.6 V |
0.6 V |
0.6 V |
— |
— |
— |
— |
— |
Temperature coefficient (TYP) |
100 ppm /°C |
100 ppm /°C |
100 ppm /°C |
100 ppm /°C |
100 ppm /°C |
100 ppm /°C |
100 ppm /°C |
100 ppm /°C |
100 ppm /°C |
Current |
|
|
|
|
|
|
|
|
|
Setting range |
0 A to 2.1 A |
0 A to 5.25 A |
0 A to 1.05 A |
0 A to 3.15 A |
0 A to 1.050 A |
0 A to 0.630 A |
0 A to 0.263 A |
0 A to 0.210 A |
0 A to 0.105 A |
Setting resolution |
0.1 mA |
0.1 mA |
0.1 mA |
0.1 mA |
0.1 mA |
0.1 mA |
0.1 mA |
0.1 mA |
0.1 mA |
Setting accuracy |
± (0.3 % of setting +0.1 % of rating) |
± (0.3 % of setting +0.1 % of rating) |
± (0.3 % of setting +0.1 % of rating) |
± (0.3 % of setting +0.1 % of rating) |
± (0.3 % of setting +0.1 % of rating) |
± (0.3 % of setting +0.1 % of rating) |
± (0.3 % of setting +0.1 % of rating) |
± (0.3 % of setting +0.1 % of rating) |
± (0.3 % of setting +0.1 % of rating) |
Line regulation |
±5 mA |
±5 mA |
±5 mA |
±5 mA |
±2 mA |
±2 mA |
±1 mA |
±1 mA |
±1 mA |
Load regulation |
±5 mA |
±5 mA |
±5 mA |
±5 mA |
±5 mA |
±5 mA |
±5 mA |
±5 mA |
±3 mA |
Ripple noise (rms) |
1 mA |
2 mA |
1 mA |
1 mA |
1 mA |
1 mA |
1 mA |
1 mA |
1 mA |
Temperature coefficient (TYP) |
200 ppm /°C |
200 ppm /°C |
200 ppm /°C |
200 ppm /°C |
200 ppm /°C |
200 ppm /°C |
200 ppm /°C |
200 ppm /°C |
200 ppm /°C |
Display Function |
|
|
|
|
|
|
|
|
|
Voltage
display |
|
|
|
|
|
|
|
|
|
Maximum display |
99.99 (fixed decimal point) |
99.99 (fixed decimal point) |
99.99 (fixed decimal point) |
99.99 (fixed decimal point) |
99.99 (fixed decimal point) |
999.9 (fixed decimal point) |
999.9 (fixed decimal point) |
999.9 (fixed decimal point) |
999.9 (fixed decimal point) |
Display accuracy |
± (0.5 % of reading +2 digits) |
± (0.5 % of reading +2 digits) |
± (0.5 % of reading +2 digits) |
± (0.5 % of reading +2 digits) |
± (0.5 % of reading +2 digits) |
± (0.5 % of reading +2 digits) |
± (0.5 % of reading +2 digits) |
± (0.5 % of reading +2 digits) |
± (0.5 % of reading +2 digits) |
Current
display |
|
|
|
|
|
|
|
|
|
Maximum display |
9.999 (fixed decimal point) |
9.999 (fixed decimal point) |
9.999 (fixed decimal point) |
9.999 (fixed decimal point) |
9.999 (fixed decimal point) |
9.999 (fixed decimal point) |
9.999 (fixed decimal point) |
9.999 (fixed decimal point) |
9.999 (fixed decimal point) |
Display accuracy |
± (1 % of reading +5 digits) |
± (1 % of reading +5 digits) |
± (1 % of reading +5 digits) |
± (1 % of reading +5 digits) |
± (1 % of reading +5 digits) |
± (1 % of reading +5 digits) |
± (1 % of reading +5 digits) |
± (1 % of reading +5 digits) |
± (1 % of reading +5 digits) |
Operation
Display |
|
|
|
|
|
|
|
|
|
OUTPUT ON / OFF |
Output on: OUTPUT LED lights in green. Output off: OUTPUT LED turns off. |
Output on: OUTPUT LED lights in green. Output off: OUTPUT LED turns off. |
Output on: OUTPUT LED lights in green. Output off: OUTPUT LED turns off. |
Output on: OUTPUT LED lights in green. Output off: OUTPUT LED turns off. |
Output on: OUTPUT LED lights in green. Output off: OUTPUT LED turns off. |
Output on: OUTPUT LED lights in green. Output off: OUTPUT LED turns off. |
Output on: OUTPUT LED lights in green. Output off: OUTPUT LED turns off. |
Output on: OUTPUT LED lights in green. Output off: OUTPUT LED turns off. |
Output on: OUTPUT LED lights in green. Output off: OUTPUT LED turns off. |
CV operation |
CV LED lights in green. |
CV LED lights in green. |
CV LED lights in green. |
CV LED lights in green. |
CV LED lights in green. |
CV LED lights in green. |
CV LED lights in green. |
CV LED lights in green. |
CV LED lights in green. |
CC operation |
CC LED lights in red. |
CC LED lights in red. |
CC LED lights in red. |
CC LED lights in red. |
CC LED lights in red. |
CC LED lights in red. |
CC LED lights in red. |
CC LED lights in red. |
CC LED lights in red. |
Alarm operation |
ALARM LED lights in red when a protection function has been activated. |
ALARM LED lights in red when a protection function has been activated. |
ALARM LED lights in red when a protection function has been activated. |
ALARM LED lights in red when a protection function has been activated. |
ALARM LED lights in red when a protection function has been activated. |
ALARM LED lights in red when a protection function has been activated. |
ALARM LED lights in red when a protection function has been activated. |
ALARM LED lights in red when a protection function has been activated. |
ALARM LED lights in red when a protection function has been activated. |
Remote operation |
REMOTE LED lights in green during remote control |
REMOTE LED lights in green during remote control |
REMOTE LED lights in green during remote control |
REMOTE LED lights in green during remote control |
REMOTE LED lights in green during remote control |
REMOTE LED lights in green during remote control |
REMOTE LED lights in green during remote control |
REMOTE LED lights in green during remote control |
REMOTE LED lights in green during remote control |
Key lock operation |
LOCK LED lights in green when the keys are locked. |
LOCK LED lights in green when the keys are locked. |
LOCK LED lights in green when the keys are locked. |
LOCK LED lights in green when the keys are locked. |
LOCK LED lights in green when the keys are locked. |
LOCK LED lights in green when the keys are locked. |
LOCK LED lights in green when the keys are locked. |
LOCK LED lights in green when the keys are locked. |
LOCK LED lights in green when the keys are locked. |
Preset memory |
When a preset memory entry is being used, the PRESET A, B, or C LED lights in green. |
When a preset memory entry is being used, the PRESET A, B, or C LED lights in green. |
When a preset memory entry is being used, the PRESET A, B, or C LED lights in green. |
When a preset memory entry is being used, the PRESET A, B, or C LED lights in green. |
When a preset memory entry is being used, the PRESET A, B, or C LED lights in green. |
When a preset memory entry is being used, the PRESET A, B, or C LED lights in green. |
When a preset memory entry is being used, the PRESET A, B, or C LED lights in green. |
When a preset memory entry is being used, the PRESET A, B, or C LED lights in green. |
When a preset memory entry is being used, the PRESET A, B, or C LED lights in green. |
Reviews