Kikusui PMX70-1A DC Power Supply 70-V 0-1A

£600.00 (£720.00 inc VAT)

Available on back-order

Description


Kikusui PMX70-1A DC Power Supply

The PMX70-1A, 70-V 0-1A, is a compact, high-performance DC power supply that provides constant voltage (CV) and constant current (CC). It is designed to improve working efficiency for benchtop uses. For this purpose, the output terminals are located on the front panel and are ergonomically designed so that wiring harnesses for electrical loads can be connected by moving your fingers naturally. Moreover, a forced air cooling system is used to intake and exhaust of the internal air, so the unit can be rack mounted without space.

Furthermore, the PMX70-1A is equipped with LAN, USB, and RS232C interfaces as standard interfaces required for system operation. In particular, the LAN interface enables you to control and monitor the power supply from Web browsers on PCs, smartphones, tablets, and other terminal devices. Moreover, the PMX-A is LXI(LAN extension for Instrumentation) certified product, so it can be connected easier with your measurement system using LAN interface.
The PMX70-1A is also equipped with analogue external control/monitoring output, various protective functions, memory function, and other functions.

Features:

  • Series regulator system with excellent noise performance
  • High setting resolution – Voltage: 1 mV, Current: 0.1 mA (PMX18-2A)
  • Wide range of output variations (9 models are available)
  • LAN (LXI compliant) / USB / RS232C as standard interface
  • External analog remote control
  • Monitoring and status signal output
  • CV, CC priority start function (to prevent overshoot when the output is ON)
  • Remote sensing function (18V, 35V models)
  • Key lock, 3-point preset memory function

Product Videos

Documentation

AC Input
Model PMX18-2A PMX18-5A PMX35-1A PMX35-3A PMX70-1A PMX110-0.6A PMX250-0.25 PMX350-0.2A PMX500-0.1A
EU/GB Models Input Rating 234Vac, 50 Hz / 60 Hz, single phase 234Vac, 50 Hz / 60 Hz, single phase 234Vac, 50 Hz / 60 Hz, single phase 234Vac, 50 Hz / 60 Hz, single phase 234Vac, 50 Hz / 60 Hz, single phase 234Vac, 50 Hz / 60 Hz, single phase 234Vac, 50 Hz / 60 Hz, single phase 234Vac, 50 Hz / 60 Hz, single phase 234Vac, 50 Hz / 60 Hz, single phase
Input voltage range ± 10 % ± 10 % ± 10 % ± 10 % ± 10 % ± 10 % ± 10 % ± 10 % ± 10 %
Input frequency range 47 Hz to 63 Hz 47 Hz to 63 Hz 47 Hz to 63 Hz 47 Hz to 63 Hz 47 Hz to 63 Hz 47 Hz to 63 Hz 47 Hz to 63 Hz 47 Hz to 63 Hz 47 Hz to 63 Hz
Power (MAX) 150VA 310VA 150VA 310VA 230VA 210VA 210VA 230VA 170VA
Output
Rating
Output voltage 18.00V 18.00V 35.00V 35.00V 70.00V 110.0V 250.0V 350.0V 500.0V
Output current 2.000A 5.000A 1.000A 3.000A 1.000A 0.600A 0.250A 0.200A 0.100A
Output power 36W 90W 35W 105W 70W 66W 62.5W 70W 50W
Voltage
Setting range 0 V to 18.90 V 0 V to 18.90 V 0 V to 36.75 V 0 V to 36.75 V 0 V to 73.5 V 0 V to 115.5 V 0 V to 262.5 V 0 V to 367.5 V 0 V to 525.0 V
Setting resolution 1 mV 1 mV 1 mV 1 mV 2 mV 10mV 10mV 10mV 10mV
Setting accuracy ± (0.2 % of setting +0.1 % of rating) ± (0.2 % of setting +0.1 % of rating) ± (0.2 % of setting +0.1 % of rating) ± (0.2 % of setting +0.1 % of rating) ± (0.2 % of setting +0.1 % of rating) ± (0.2 % of setting +0.1 % of rating) ± (0.2 % of setting +0.1 % of rating) ± (0.2 % of setting +0.1 % of rating) ± (0.2 % of setting +0.1 % of rating)
Line regulation ±1 mV ±1 mV ±3 mV ±3 mV ±5 mV ±7 mV ±15 mV ±25 mV ±30 mV
Load regulation ±2 mV ±5 mV ±3 mV ±4 mV ±5 mV ±7 mV ±15 mV ±25 mV ±30 mV
Transient response 50 μs 50 μs 50 μs 50 μs 100 μs 100 μs 100 μs 100 μs 100 μs
Ripple noise (rms) 0.5 mV 0.5 mV 0.5 mV 0.5 mV 1mV 2mV 3mV 5mV 10mV
Rise time Rated Load: 120 ms or less

No Load: 120 ms or less

Rated Load: 120 ms or less

No Load: 120 ms or less

Rated Load: 120 ms or less

No Load: 120 ms or less

Rated Load: 120 ms or less

No Load: 120 ms or less

Rated Load: 150 ms or less

No Load: 150 ms or less

Rated Load: 120 ms or less

No Load: 120 ms or less

Rated Load: 120 ms or less

No Load: 120 ms or less

Rated Load: 150 ms or less

No Load: 150 ms or less

Rated Load: 120 ms or less

No Load: 120 ms or less

Fall time Rated Load: 50 ms or less

No Load: 270 ms or less

Rated Load: 50 ms or less

No Load: 320 ms or less

Rated Load: 50 ms or less

No Load: 270 ms or less

Rated Load: 50 ms or less

No Load: 270 ms or less

Rated Load: 50 ms or less

No Load: 270 ms or less

Rated Load: 50 ms or less

No Load: 120 ms or less

Rated Load: 50 ms or less

No Load: 120 ms or less

Rated Load:80 ms or less

No Load: 220 ms or less

Rated Load: 50 ms or less

No Load: 60 ms or less

Maximum remote sensing
compensation voltage(single line)
0.6 V 0.6 V 0.6 V 0.6 V
Temperature coefficient (TYP) 100 ppm /°C 100 ppm /°C 100 ppm /°C 100 ppm /°C 100 ppm /°C 100 ppm /°C 100 ppm /°C 100 ppm /°C 100 ppm /°C
Current
Setting range 0 A to 2.1 A 0 A to 5.25 A 0 A to 1.05 A 0 A to 3.15 A 0 A to 1.050 A 0 A to 0.630 A 0 A to 0.263 A 0 A to 0.210 A 0 A to 0.105 A
Setting resolution 0.1 mA 0.1 mA 0.1 mA 0.1 mA 0.1 mA 0.1 mA 0.1 mA 0.1 mA 0.1 mA
Setting accuracy ± (0.3 % of setting +0.1 % of rating) ± (0.3 % of setting +0.1 % of rating) ± (0.3 % of setting +0.1 % of rating) ± (0.3 % of setting +0.1 % of rating) ± (0.3 % of setting +0.1 % of rating) ± (0.3 % of setting +0.1 % of rating) ± (0.3 % of setting +0.1 % of rating) ± (0.3 % of setting +0.1 % of rating) ± (0.3 % of setting +0.1 % of rating)
Line regulation ±5 mA ±5 mA ±5 mA ±5 mA ±2 mA ±2 mA ±1 mA ±1 mA ±1 mA
Load regulation ±5 mA ±5 mA ±5 mA ±5 mA ±5 mA ±5 mA ±5 mA ±5 mA ±3 mA
Ripple noise (rms) 1 mA 2 mA 1 mA 1 mA 1 mA 1 mA 1 mA 1 mA 1 mA
Temperature coefficient (TYP) 200 ppm /°C 200 ppm /°C 200 ppm /°C 200 ppm /°C 200 ppm /°C 200 ppm /°C 200 ppm /°C 200 ppm /°C 200 ppm /°C
Display Function
Voltage
display
Maximum display 99.99 (fixed decimal point) 99.99 (fixed decimal point) 99.99 (fixed decimal point) 99.99 (fixed decimal point) 99.99 (fixed decimal point) 999.9 (fixed decimal point) 999.9 (fixed decimal point) 999.9 (fixed decimal point) 999.9 (fixed decimal point)
Display accuracy ± (0.5 % of reading +2 digits) ± (0.5 % of reading +2 digits) ± (0.5 % of reading +2 digits) ± (0.5 % of reading +2 digits) ± (0.5 % of reading +2 digits) ± (0.5 % of reading +2 digits) ± (0.5 % of reading +2 digits) ± (0.5 % of reading +2 digits) ± (0.5 % of reading +2 digits)
Current
display
Maximum display 9.999 (fixed decimal point) 9.999 (fixed decimal point) 9.999 (fixed decimal point) 9.999 (fixed decimal point) 9.999 (fixed decimal point) 9.999 (fixed decimal point) 9.999 (fixed decimal point) 9.999 (fixed decimal point) 9.999 (fixed decimal point)
Display accuracy ± (1 % of reading +5 digits) ± (1 % of reading +5 digits) ± (1 % of reading +5 digits) ± (1 % of reading +5 digits) ± (1 % of reading +5 digits) ± (1 % of reading +5 digits) ± (1 % of reading +5 digits) ± (1 % of reading +5 digits) ± (1 % of reading +5 digits)
Operation
Display
OUTPUT ON / OFF Output on: OUTPUT LED lights in green. Output off: OUTPUT LED turns off. Output on: OUTPUT LED lights in green. Output off: OUTPUT LED turns off. Output on: OUTPUT LED lights in green. Output off: OUTPUT LED turns off. Output on: OUTPUT LED lights in green. Output off: OUTPUT LED turns off. Output on: OUTPUT LED lights in green. Output off: OUTPUT LED turns off. Output on: OUTPUT LED lights in green. Output off: OUTPUT LED turns off. Output on: OUTPUT LED lights in green. Output off: OUTPUT LED turns off. Output on: OUTPUT LED lights in green. Output off: OUTPUT LED turns off. Output on: OUTPUT LED lights in green. Output off: OUTPUT LED turns off.
CV operation CV LED lights in green. CV LED lights in green. CV LED lights in green. CV LED lights in green. CV LED lights in green. CV LED lights in green. CV LED lights in green. CV LED lights in green. CV LED lights in green.
CC operation CC LED lights in red. CC LED lights in red. CC LED lights in red. CC LED lights in red. CC LED lights in red. CC LED lights in red. CC LED lights in red. CC LED lights in red. CC LED lights in red.
Alarm operation ALARM LED lights in red when a protection function has been activated. ALARM LED lights in red when a protection function has been activated. ALARM LED lights in red when a protection function has been activated. ALARM LED lights in red when a protection function has been activated. ALARM LED lights in red when a protection function has been activated. ALARM LED lights in red when a protection function has been activated. ALARM LED lights in red when a protection function has been activated. ALARM LED lights in red when a protection function has been activated. ALARM LED lights in red when a protection function has been activated.
Remote operation REMOTE LED lights in green during remote control REMOTE LED lights in green during remote control REMOTE LED lights in green during remote control REMOTE LED lights in green during remote control REMOTE LED lights in green during remote control REMOTE LED lights in green during remote control REMOTE LED lights in green during remote control REMOTE LED lights in green during remote control REMOTE LED lights in green during remote control
Key lock operation LOCK LED lights in green when the keys are locked. LOCK LED lights in green when the keys are locked. LOCK LED lights in green when the keys are locked. LOCK LED lights in green when the keys are locked. LOCK LED lights in green when the keys are locked. LOCK LED lights in green when the keys are locked. LOCK LED lights in green when the keys are locked. LOCK LED lights in green when the keys are locked. LOCK LED lights in green when the keys are locked.
Preset memory When a preset memory entry is being used, the PRESET A, B, or C LED lights in green. When a preset memory entry is being used, the PRESET A, B, or C LED lights in green. When a preset memory entry is being used, the PRESET A, B, or C LED lights in green. When a preset memory entry is being used, the PRESET A, B, or C LED lights in green. When a preset memory entry is being used, the PRESET A, B, or C LED lights in green. When a preset memory entry is being used, the PRESET A, B, or C LED lights in green. When a preset memory entry is being used, the PRESET A, B, or C LED lights in green. When a preset memory entry is being used, the PRESET A, B, or C LED lights in green. When a preset memory entry is being used, the PRESET A, B, or C LED lights in green.

Note* Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Mandatory Accessories …