Langer EMV-Technik A100-2, 2 Channel, 25kHz, Optical Fibre Probe Set

The A100-2 set is used for oscillographing analogue signals under EFT/ESD/RF interference. The set is particularly suitable for the measurement of analogue signals when testing the immunity of electrical or electronic devices (equipment) against high-frequency electromagnetic fields (IEC 61000-4-3 to IEC 61000-4-6). This system is suitable for signal control in an anechoic chamber or EMC-compliant space.

The set consists of two sensors which measure an analogue signal within the device under test and transform it into optical signals. The optical signals are transmitted via a fibre-optic cable to the optical receiver, which then transforms them into electrical signals. Those can be seen with an oscilloscope or can be used for controlling other devices.
For signal detection within the device under test, several sensor types, AS 100, AS 110 or AS 120, with different measuring ranges are available.

By applying the prescribed modulation models for electromagnetic fields, signal influences can be easily detected using the A100 set, A200 set and A300 set analogue measuring systems.
With the optical transmission system hard- and software can be EMC-optimized, because disturbed signals can be easily detected.

The A100-2 set consists of 2 sensors. These sensors allow for the oscillography of floating analogue signals under EFT/ESD/RF disturbance. Disturbed signals can be easily detected. A sensor transforms measured logical signals within the device under test into light signals. Via the optical fibre cables, these light signals are transmitted to an optical receiver, which transforms them into electrical signals. They can be seen with an oscilloscope or used for controlling other devices. For measurements, several sensor types with different measurement ranges are available. The system is useful for signal- and DUT monitoring in an anechoic chamber or for EMC optimisation of hardware and software.

Scope of Delivery
  • 2x AE 100, Optical Receiver
  • 2x AS 100, Optical Sensor (50 / 10) V DC
  • 2x LWL Ø 2.2 mm 6 m, Optical Fibre, Single 6 m
  • 1x NT FRI EU, Power Supply Unit
  • 1x A100-2 acc, Accessories
  • 1x A100-2 case, System Case
  • 1x Analogue m, User Manual

Product Videos

Documentation

Bandwidth DC … 25 kHz
Sampling rate 125 ksps
Resolution 12 Bit
AE 100 Optical Receiver
Bandwidth DC … 25 kHz
Optical input: Optical fiber Ø 2.2 mm
Voltage range – output 0 V … 10 V
Supply voltage 12 V … 16 V
Current input ≈ 30 mA
Connector – output BNC
AS 100 Optical Sensor
Bandwidth DC … 25 kHz
Sampling rate 125 ksps
Measuring range 0 V … 50 V / 0 V … 10 V DC (switchable)
Input resistance 100 kΩ
Radiated immunity > 200 V/m
Supply voltage 3 V … 16 V
Current input ≈ 3 mA
Optical fibre length 1 m … 20 m

Optional Accessories …

  • Image of Langer 2014 as110 h w telonicuk

    Langer EMV-Technik AS 110 Optical Sensor (10 / 1) V DC

    .

    Available on back-order

    Availability: Stock models delivered next working day (UK only) for orders placed before 16:30 (Mon - Fri)

    Read more
  • Image of Langer 2014 as120 h w telonicuk

    Langer EMV-Technik AS 120 Optical Sensor (1 / 0, 1) V AC

    .

    Available on back-order

    Availability: Stock models delivered next working day (UK only) for orders placed before 16:30 (Mon - Fri)

    Read more