Kikusui PCR6000WE2 AC Power Supply / Frequency Converter Single-Phase 6kVA, AC 0 to 310Vrms, 1Hz to 5kHz, DC0 to ±438V, PWM type
. (£ inc VAT)
Available on back-order
The PCR6000WE2 is a Single-Phase 6kVA, AC 0 to 310Vrms, 1Hz to 5kHz, DC0 to ±438V AC Power Supply / Frequency Converter. The PCR-WE/WE2 is a series of multifunctional switching AC power supplies that combines accurate, high power output and ultra-compact design. The 15 model line-up ranges from 1 kVA to 36 kVA AC/DC with single & 3 phase variable output from 6 kVA and up. The PCR-WE/WE2 also features a regenerative mode*1 that can drastically reduce power consumption and cut the costs of operation. The PCR-WE/WE2 also supports mix-and-match parallel operation*2 up to 144 kVA for large scale test systems. Output frequency up to 5 kHz is also available with all models for critical AC applications in the avionic industries. Compact Size! Compared to our previous PWM models, the size of the PCR-WE has been drastically reduced up to 60%. Efficiency has also been increased by approximately 7%, for an overall high efficiency of approximately 85%. Low Ripple Noise Extremely low switching noise for a PWM inverter type AC power supply, with ripple noise as low as 0.25 rms achieved with 1 kVA - 6kVA models. The PCR-WE series even boasts similar noise performance to the PCR-LE/LE2 linear amplifier power supply series. The compact, high power design of the PCR-WE/WE2 has been achieved with absolutely no compromises to ripple noise performance. Output Frequency up to 5 kHz Maximum output frequency up to 5 kHz for critical applications in the defense and avionics industries. The frequency performance of the PCR-WE allows for simulation of sharp voltage fluctuations required airborne electronic equipment testing. Furthermore, the compact 6kVA/6U form factor allows for the easy preparation of an automated, one rack testing system without requiring a costly, specialized power source installation space. LAN, USB, RS232C Standard Digital Interface The PCR-WE/WE2 series includes a flexible digital interface for users utilizing LAN, USB, and RS232C communication interfaces (GPIB factory option available). LAN connection is LXI compliant, allowing you to monitor and control your device wherever you are via computer, smartphone, or tablet web browser. This feature is particularly important when conducting critical AC tests in anechoic chambers/shield rooms. Power Line Error Simulation The PCR-WE/WE2 series can simulate various power line abnormalities such as power outages, voltage drops (dips) and voltage increases (pops). This feature is useful for the testing of power source switches and various electronic devices.
-
UK Power Cord
Standard Hardware Accessories
Documentation
Datasheet
User Manual
Interface Manual
Kikusui PCRWE-WE2 Interface Manual
Application Notes
Compact design with high energy density brings you a drastic space-saving
Various features to support wide range of application
Various communication interfaces
Single-phase Three-wire Output from One AC Power Supply
How to Reduce Power Supply Noise
What Makes a Good Power Supply?
How to use the power line disturbance simulation function of PCR-WE
How to use the voltage correction function on frequency response
Input (AC rms) | |||||||||
---|---|---|---|---|---|---|---|---|---|
Model | PCR1000WE | PCR2000WE | PCR3000WE2 | PCR6000WE2 | PCR12000WE2 | PCR18000WE2 | PCR24000WE2 | PCR30000WE2 | PCR36000WE2 |
Nominal input voltage | 1P2W Input Model: 100 Vac to 120 Vac / 200 Vac to 240 Vac | 1P2W Input Model: 100 Vac to 120 Vac / 200 Vac to 240 Vac | 1P2W Input Model: 100 Vac to 120 Vac / 200 Vac to 240 Vac | 3P3W Input Model: 200 Vac to 240 Vac (3 phase line voltage) 3P4W Input Model: 380 Vac to 480 Vac (3 phase line voltage) |
3P3W Input Model: 200 Vac to 240 Vac (3 phase line voltage) 3P4W Input Model: 380 Vac to 480 Vac (3 phase line voltage) |
3P3W Input Model: 200 Vac to 240 Vac (3 phase line voltage) 3P4W Input Model: 380 Vac to 480 Vac (3 phase line voltage) |
3P3W Input Model: 200 Vac to 240 Vac (3 phase line voltage) 3P4W Input Model: 380 Vac to 480 Vac (3 phase line voltage) |
3P3W Input Model: 200 Vac to 240 Vac (3 phase line voltage) 3P4W Input Model: 380 Vac to 480 Vac (3 phase line voltage) |
3P3W Input Model: 200 Vac to 240 Vac (3 phase line voltage) 3P4W Input Model: 380 Vac to 480 Vac (3 phase line voltage) |
Phase | Single-phase | Single-phase | Single-phase | Three-phase | Three-phase | Three-phase | Three-phase | Three-phase | Three-phase |
Nominal input Frequency | 50 Hz to 60 Hz | 50 Hz to 60 Hz | 50 Hz to 60 Hz | 50 Hz to 60 Hz | 50 Hz to 60 Hz | 50 Hz to 60 Hz | 50 Hz to 60 Hz | 50 Hz to 60 Hz | 50 Hz to 60 Hz |
Input frequency range | 45 Hz to 65 Hz | 45 Hz to 65 Hz | 45 Hz to 65 Hz | 45 Hz to 65 Hz | 45 Hz to 65 Hz | 45 Hz to 65 Hz | 45 Hz to 65 Hz | 45 Hz to 65 Hz | 45 Hz to 65 Hz |
Apparent power | 1.4kVA and less | 2.7kVA and less | 4kVA and less | 7.8kVA and less | 15.6kVA and less | 23.4kVA and less | 31.2kVA and less | 39kVA and less | 46.8kVA and less |
Power factor | 0.95(TYP) | 0.95(TYP) | 0.95(TYP) | 0.97(TYP) 3P3W input model / 0.95(TYP) 3P4W input model | 0.97(TYP) 3P3W input model / 0.95(TYP) 3P4W input model | 0.97(TYP) 3P3W input model / 0.95(TYP) 3P4W input model | 0.97(TYP) 3P3W input model / 0.95(TYP) 3P4W input model | 0.97(TYP) 3P3W input model / 0.95(TYP) 3P4W input model | 0.97(TYP) 3P3W input model / 0.95(TYP) 3P4W input model |
Maximum current | 1P2W input model: 17 A / 8.5 A 32 A / 16 A 48 A / 24 A | 1P2W input model: 17 A / 8.5 A 32 A / 16 A 48 A / 24 A | 1P2W input model: 17 A / 8.5 A 32 A / 16 A 48 A / 24 A | 3P3W Input Model: 27A 3P4W Input Model: 14A |
3P3W Input Model: 53A 3P4W Input Model: 28A |
3P3W Input Model: 80A 3P4W Input Model: 42A |
3P3W Input Model: 106A 3P4W Input Model: 56A |
3P3W Input Model: 133A 3P4W Input Model: 70A |
3P3W Input Model: 159A 3P4W Input Model: 84A |
Holdup time for power interruption | 10 ms | 10 ms | 10 ms | 10 ms | 10 ms | 10 ms | 10 ms | 10 ms | 10 ms |
Output | |||||||||
Model | PCR1000WE | PCR2000WE | PCR3000WE2 | PCR6000WE2 | PCR12000WE2 | PCR18000WE2 | PCR24000WE2 | PCR30000WE2 | PCR36000WE2 |
AC Voltage | |||||||||
Rating | 155 V / 310 V | 155 V / 310 V | 155 V / 310 V | 155 V / 310 V | 155 V / 310 V | 155 V / 310 V | 155 V / 310 V | 155 V / 310 V | 155 V / 310 V |
Setting Range | 0 V to 157.5 V / 0 V to 315.0 V | 0 V to 157.5 V / 0 V to 315.0 V | 0 V to 157.5 V / 0 V to 315.0 V | 0 V to 157.5 V / 0 V to 315.0 V | 0 V to 157.5 V / 0 V to 315.0 V | 0 V to 157.5 V / 0 V to 315.0 V | 0 V to 157.5 V / 0 V to 315.0 V | 0 V to 157.5 V / 0 V to 315.0 V | 0 V to 157.5 V / 0 V to 315.0 V |
Setting Resolution | 0.1 V | 0.1 V | 0.1 V | 0.1 V | 0.1 V | 0.1 V | 0.1 V | 0.1 V | 0.1 V |
Setting accuracy (phase voltage) |
±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) | ±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) | ±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) | ±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) | ±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) | ±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) | ±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) | ±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) | ±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) |
Setting accuracy (Line voltage) |
±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) | ±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) | ±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) | ±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) | ±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) | ±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) | ±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) | ±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) | ±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) |
Maximum current |
|||||||||
Single-phase output | 10 A / 5 A | 20 A / 10 A | 30 A / 15 A | 60A / 30A | 120A / 60A | 180A / 90A | 240A / 120A | 300A / 150A | 360A / 180A |
Single-phase three-wire output, Three-phase output |
10A / 5A | 20A / 10A | 40A / 20A | 60A / 30A | 80A / 40A | 100A / 50A | 120A / 60A | ||
Phase | 1P | 1P | 1P2W, 1P3W, 3P4W switchable | 1P2W, 1P3W, 3P4W switchable | 1P2W, 1P3W, 3P4W switchable | 1P2W, 1P3W, 3P4W switchable | 1P2W, 1P3W, 3P4W switchable | 1P2W, 1P3W, 3P4W switchable | 1P2W, 1P3W, 3P4W switchable |
Power capacity |
|||||||||
Single-phase output | 1 kVA | 2 kVA | 3kVA | 6kVA | 12kVA | 18kVA | 24kVA | 30kVA | 36kVA |
Three-phase output | – – – | – – – | 3kVA | 6kVA | 12kVA | 18kVA | 24kVA | 30kVA | 36kVA |
Single-phase ― three-wire output |
– – – | – – – | 2kVA | 4kVA | 8kVA | 12kVA | 16kVA | 20kVA | 24kVA |
Maximum peak current | 4 times the maximum output current | 4 times the maximum output current | 4 times the maximum output current | 4 times the maximum output current | 4 times the maximum output current | 4 times the maximum output current | 4 times the maximum output current | 4 times the maximum output current | 4 times the maximum output current |
Inrush current capacity | 3 times the rated current (0.07 s) | 3 times the rated current (0.07 s) | 3 times the rated current (0.07 s) | 1.4 times the rated current (0.5 s) | 1.4 times the rated current (0.5 s) | 1.4 times the rated current (0.5 s) | 1.4 times the rated current (0.5 s) | 1.4 times the rated current (0.5 s) | 1.4 times the rated current (0.5 s) |
Load power factor | 0 to 1 (leading or lagging) | 0 to 1 (leading or lagging) | 0 to 1 (leading or lagging) | 0 to 1 (leading or lagging) | 0 to 1 (leading or lagging) | 0 to 1 (leading or lagging) | 0 to 1 (leading or lagging) | 0 to 1 (leading or lagging) | 0 to 1 (leading or lagging) |
Frequency | |||||||||
Setting range | 1 Hz to 5 kHz (5 kHz -3dB, <40 Hz derating required) | 1 Hz to 5 kHz (5 kHz -3dB, <40 Hz derating required) | 1 Hz to 5 kHz (5 kHz -3dB, <40 Hz derating required) | 1 Hz to 5 kHz (5 kHz -3dB, <40 Hz derating required) | 1 Hz to 5 kHz (5 kHz -3dB, <40 Hz derating required) | 1 Hz to 5 kHz (5 kHz -3dB, <40 Hz derating required) | 1 Hz to 5 kHz (5 kHz -3dB, <40 Hz derating required) | 1 Hz to 5 kHz (5 kHz -3dB, <40 Hz derating required) | 1 Hz to 5 kHz (5 kHz -3dB, <40 Hz derating required) |
Resolution | 0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz) | 0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz) | 0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz) | 0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz) | 0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz) | 0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz) | 0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz) | 0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz) | 0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz) |
Accuracy | ±0.01 %, Temperature coefficient : ±0.005 %/°C | ±0.01 %, Temperature coefficient : ±0.005 %/°C | ±0.01 %, Temperature coefficient : ±0.005 %/°C | ±0.01 %, Temperature coefficient : ±0.005 %/°C | ±0.01 %, Temperature coefficient : ±0.005 %/°C | ±0.01 %, Temperature coefficient : ±0.005 %/°C | ±0.01 %, Temperature coefficient : ±0.005 %/°C | ±0.01 %, Temperature coefficient : ±0.005 %/°C | ±0.01 %, Temperature coefficient : ±0.005 %/°C |
Phase | |||||||||
Resolution | – – – | – – – | 0.1°(1 Hz to 500 Hz), 1°(500 Hz to 4 kHz), 2°(4 kHz or more) | 0.1°(1 Hz to 500 Hz), 1°(500 Hz to 4 kHz), 2°(4 kHz or more) | 0.1°(1 Hz to 500 Hz), 1°(500 Hz to 4 kHz), 2°(4 kHz or more) | 0.1°(1 Hz to 500 Hz), 1°(500 Hz to 4 kHz), 2°(4 kHz or more) | 0.1°(1 Hz to 500 Hz), 1°(500 Hz to 4 kHz), 2°(4 kHz or more) | 0.1°(1 Hz to 500 Hz), 1°(500 Hz to 4 kHz), 2°(4 kHz or more) | 0.1°(1 Hz to 500 Hz), 1°(500 Hz to 4 kHz), 2°(4 kHz or more) |
Accuracy | – – – | – – – | Within 120°±(0.4°+2.5 μs) Within (120°±(0.4°+fo×0.9×10-3°)) fo : frequency [kHz] | Within 120°±(0.4°+2.5 μs) Within (120°±(0.4°+fo×0.9×10-3°)) fo : frequency [kHz] | Within 120°±(0.4°+2.5 μs) Within (120°±(0.4°+fo×0.9×10-3°)) fo : frequency [kHz] | Within 120°±(0.4°+2.5 μs) Within (120°±(0.4°+fo×0.9×10-3°)) fo : frequency [kHz] | Within 120°±(0.4°+2.5 μs) Within (120°±(0.4°+fo×0.9×10-3°)) fo : frequency [kHz] | Within 120°±(0.4°+2.5 μs) Within (120°±(0.4°+fo×0.9×10-3°)) fo : frequency [kHz] | Within 120°±(0.4°+2.5 μs) Within (120°±(0.4°+fo×0.9×10-3°)) fo : frequency [kHz] |
DC voltage |
|||||||||
Rating | -219 V to +219 V / -438 V to +438 V | -219 V to +219 V / -438 V to +438 V | -219 V to +219 V / -438 V to +438 V | -219 V to +219 V / -438 V to +438 V | -219 V to +219 V / -438 V to +438 V | -219 V to +219 V / -438 V to +438 V | -219 V to +219 V / -438 V to +438 V | -219 V to +219 V / -438 V to +438 V | -219 V to +219 V / -438 V to +438 V |
Setting range | -222.5 V to +222.5 V / -445.0 V to +445.0 V | -222.5 V to +222.5 V / -445.0 V to +445.0 V | -222.5 V to +222.5 V / -445.0 V to +445.0 V | -222.5 V to +222.5 V / -445.0 V to +445.0 V | -222.5 V to +222.5 V / -445.0 V to +445.0 V | -222.5 V to +222.5 V / -445.0 V to +445.0 V | -222.5 V to +222.5 V / -445.0 V to +445.0 V | -222.5 V to +222.5 V / -445.0 V to +445.0 V | -222.5 V to +222.5 V / -445.0 V to +445.0 V |
Resolution | 0.1 V | 0.1 V | 0.1 V | 0.1 V | 0.1 V | 0.1 V | 0.1 V | 0.1 V | 0.1 V |
Accuracy | ±(0.05 % of setting +0.1 V) | ±(0.05 % of setting +0.1 V) | ±(0.05 % of setting +0.1 V) | ±(0.05 % of setting +0.1 V) | ±(0.05 % of setting +0.1 V) | ±(0.05 % of setting +0.1 V) | ±(0.05 % of setting +0.1 V) | ±(0.05 % of setting +0.1 V) | ±(0.05 % of setting +0.1 V) |
Maximum current | 10A / 5A | 20A / 10A | 30A / 15A | 60A / 30A | 120A / 60A | 180A / 90A | 240A / 120A | 300A / 150A | 360A / 180A |
Power capacity | 1kW | 2kW | 3kW | 6kW | 12kW | 18kW | 24kW | 30kW | 36kW |
Efficiency | 82 %(TYP) | 82 %(TYP) | 82 %(TYP) | 85 %(TYP) | 85 %(TYP) | 85 %(TYP) | 85 %(TYP) | 85 %(TYP) | 85 %(TYP) |
Note* Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.
Only logged in customers who have purchased this product may leave a review.
Mandatory Accessories …
Optional Accessories …
-
Kikusui IB07-PCR-WE GPIB Interface
£282.00 Add to basket -
Kikusui PC01-PCR-WE Parallel Operation Cable
£176.00 Add to basket -
Kikusui OP02-PCR-WE External Control Connector (for ANALOGUE I/O)
£27.00 Add to basket -
Kikusui OP01-PCR-WE External Control Connector (for DIGITAL I/O)
£34.002 in stock (can be backordered)
Availability: Stock models delivered next working day (UK only) for orders placed before 16:30 (Mon - Fri)
Add to basket -
Kikusui KRB6 Bracket
£155.00 Add to basket
Reviews