Description
Danisense DS50ID Current Transducer
Danisense DS50ID (AC:50Arms, DC:75A) is ultra-stable, high precision (ppm class) fluxgate technology DS series Current Transducer for non-intrusive, isolated DC and AC measurement up to 150A.
FREE SHIPPING £75+
CELEBRATING 50+ YEARS
PRICE MATCH GUARANTEE
£563.00 (£675.60 inc VAT)
Available on back-order
Danisense DS50ID Current Transducer
Danisense DS50ID (AC:50Arms, DC:75A) is ultra-stable, high precision (ppm class) fluxgate technology DS series Current Transducer for non-intrusive, isolated DC and AC measurement up to 150A.
| Specifications Highlights | Symbol | Unit | Min | Typ | Max |
|---|---|---|---|---|---|
| Nominal primary AC current | IPN AC | Arms | 50 | ||
| Nominal primary DC current | IP N DC | A | -75 | 75 | |
| Measuring range | ÎP M | A | -150 | 150 | |
| Primary / secondary ratio | n1 : n2 | 1:500 | 1:500 | ||
| Linearity error | ƐL | ppm | -8 | 8 | |
| Offset current (including earth field) | IOE | ppm | -80 | 80 | |
| DC-10Hz Overall accuracy @25°C (= ƐL + IOE ) | accƐ | ppm | -88 | 88 | |
| AC Maximum gain error 10Hz to 5kHz | ƐG | % | ±0.04 | ||
| Operating temperature range | Ta | °C | -40 | 85 | |
| Power supply voltages | Uc | V | ±14.25 | ±15.75 |
Note* Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.