Danisense DS50ID Zero Flux Current Transducer AC:50Arms, DC:75A

£566.00 (£679.20 inc VAT)

Available on back-order

SKU: DS50ID Categories: ,

Description


Danisense DS50ID Current Transducer

Danisense DS50ID (AC:50Arms, DC:75A) is ultra-stable, high precision (ppm class) fluxgate technology DS series Current Transducer for non-intrusive, isolated DC and AC current measurement up to 150A.

  • MPS for particles accelerators
  • Gradient amplifiers for MRI devices
  • Stable power supplies
  • Precision Drives
  • Batteries testing and evaluation systems
  • Power measurement and power analysis
  • Precision current calibration purposes

Features:

  • Linearity error maximum 8 ppm
  • Fluxgate, closed loop compensated technology with fixed excitation frequency and second harmonic zero flux detection for enhanced accuracy and stability
  • Industry standard DSUB 9 pin connection
  • Green diode for normal operation indication
  • Full aluminium body for superior EMI shielding and extended operating temperature range
  • Large aperture 27.6mm cables and bus bars

Documentation

Specifications HighlightsSymbolUnitMinTypMax
Nominal primary AC currentIPN ACArms50
Nominal primary DC currentIP N DCA-7575
Measuring rangeÎP MA-150150
Primary / secondary ration1 : n21:5001:500
Linearity errorƐLppm-88
Offset current (including earth field)IOEppm-8080
DC-10Hz Overall accuracy @25°C (= ƐL + IOE )accƐppm-8888
AC Maximum gain error 10Hz to 5kHzƐG%±0.04
Operating temperature rangeTa°C-4085
Power supply voltagesUcV±14.25±15.75

Note* Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.