EMI Test System Software Getting Started Guide
The Rigol EMI Test System Software is designed to make precompliance scanning with a Rigol DSA family of Spectrum Analyzer easy. This Note is an addendum to the Software User’s Guide. We will…
Read moreFrom the blog
The Rigol EMI Test System Software is designed to make precompliance scanning with a Rigol DSA family of Spectrum Analyzer easy. This Note is an addendum to the Software User’s Guide. We will…
Read more
The latest revision of firmware (DSA815 00.01.12) has the ability to save a prefix for use with file saves. This can make data entry a bit easier. - Press SYSTEM > Down…
Read more
Select Tools at the top of the S1210 application window.You can now open the Data Manager and select CSV to convert a CSV file into a correction file.
Read more
To save a trace as a CSV: 1) Insert USB stick into the USB port on the front panel NOTE: The format of the USB stick must be FAT32 2) Press STORAGE > Set BROWSER…
Read more
To reset the RSA3000, RSA3000E and the RSA5000 series to factory settings without using the System menu:1) Power cycle the instrument2) During the boot sequence, quickly and repeatedly press the Back button…
Read more
RIGOL’s RSA3000/3000E/5000 series product uses a number of open source software packages. This document lists the open source software packages used in RSA3000/3000E/5000 series product. https://beyondmeasure.rigoltech.com/acton/attachment/1579/f-be0541d6-bc36-481f-b448-ec059be1b26e/1/-/-/-/-/RSA3000_3000E_5000.pdf
Read more
In order to take a screen shot on the RSA5000, RSA3000 or RSA3000E and have it automatically save to your flash drive follow the steps below.1) Insert flash drive into the instrument…
Read more
If your DSA800 series spectrum analyser does not boot when powered up it may be possible to correct the issue by booting off of a USB memory stick. When the spectrum analyser…
Read more
Recent versions of DSA815 Firmware and S1210 software improved the operation of the amplitude units in the software. These versions are: Instrument Firmware – 00.01.19 1210 Software – 05.00.07 On occasion it…
Read more
Once a pre-scan has been done there are 2 ways to add a marker: Double click on the graph in the Measure window. That will create a marker in the Marker Table:…
Read more
Relative measurements are critical in EMI: How does the good board compare to the failed board? How does this look with the CISPR Average detector or against another limit line? Is that…
Read more
Make EMI measurements simpler and faster by automating the process. Combine scans, searches, and interactive measurements. Also conduct further analysis on signals of interest with a single button on the same instrument…
Read moreChoose which cookies we can use. Strictly necessary cookies are always on because the website cannot work without them. Everything else is off until you switch it on.
Your browser is sending a Global Privacy Control signal. Marketing cookies stay off unless you switch them on here or choose "Accept all".
Needed for the website to work, for example to keep you signed in, remember your basket, keep the site secure and remember your cookie choices. These cannot be switched off.
| Cookie | Set by | Purpose | Kept for |
|---|---|---|---|
jgwm_cookie_consent |
This website | Remembers your cookie choices so we do not ask again on every page. | 6 months |
Help us understand how visitors use the website, for example which pages are popular and how people find us, so we can improve it.
Let us see which advert, campaign or website brought you here and whether your visit led to an enquiry or order, so we know which adverts work. Advertising partners may also use them to show you relevant adverts on other websites.