Black or Green Terminal on a Power Supply

Our power supplies are isolated power supplies. So when you connect to the black negative terminal you have connected your DUT to an isolated channel.  Where as if you connect to the green terminal you are connecting your DUT to ground which will no longer have the power supply act as an isolated supply....

DP700 Reaction Time for OVP, OCP and OPP being Exceeded

The image below shows how quickly the DP700 will turn off its output when it detects that OVP, OCP or OPP has been exceeded.  The instrument below shut off its output power 26ms after it started creating the higher voltage.  ...

How to Load a DP700 License Option

DP700 series power supply provides the following options:     Trigger: provides the trigger input and output functions.     Timer: outputs based on the preset voltage and current values.     High Resolution: improves the resolution of the instrument....

DP700 Trigger output operation

The DP700 series power supply can receive a trigger to enable the output of the supply. Pin 8 of the RS232 interface on the rear panel is used for trigger input, ...

DP700 transient voltage on power up

The DP700 series power supply will show a transient voltage on the outputs when the power supply is powered up. Typically the transient voltage will show approximately 400mV p-p over a 200us duration. The DP700 power supplies do not have output relays to to  enable output after the power supply has been  turned on and...

Timer operation with the DP700 series power supply

The DP700 series power supply provides a timer function. When the timing output is enabled, the instrument will configure the output voltages and currents based on the preset timer parameters. The edited timer parameters are allowed to be saved to the internal non-volatile memory (NVM), and can be recalled if necessary. ...

DP700 series Power Supply Maximum Trigger Input Voltage

Pin 8 of the RS232 interface on the rear panel is used to receive the external trigger input signal. When it receives a high level signal (≥ 2.1 V, 10 mA), the channel output will be turned on. If 8 volts or greater is applied damage to the power supply I/O circuit can result....

Serial Cable for the DP700 series Power Supply

The DP700 series power supplies have a single serial I/O port. If you plan on programming the DP700 power supply from a PC you will need a USB to serial cable. An example is pictured here: ...