Danisense DM1200UB-10V Zero Flux Current Transducer AC:850Arms, DC:1200A

£1838.00 (£2,205.60 inc VAT)

Available on back-order

SKU: DM1200UB-10V Categories: ,

Description


Danisense DM1200UB-10V Current Transducer

Danisense DM1200UB-10V (AC:850Arms, DC:1200A) is an Ultra-stable, high precision (ppm class) fluxgate technology DM Series Current Transducer for non-intrusive, isolated DC and AC current measurement up to 1320A.

  • Power measurement and power analysis
  • Stable power supplies
  • MPS for particles accelerators
  • Gradient amplifiers for MRI devices
  • Precision drives
  • Batteries testing and evaluation systems
  • Current calibration purposes

Features:

  • Ø45mm aperture
  • 15 ppm linearity,
  • 10 ppm offset
  • 10V output
  • Fluxgate, closed loop compensated technology with crystal driven excitation frequency for increased stability
  • Industry standard DSUB 9 pin connection
  • Full aluminium body for superior EMI shielding and extended operating temperature range
Specifications HighlightsSymbolUnitMinTypMax
Nominal primary AC currentIPN ACArms850
Nominal primary DC currentIPN DCA-12001200
Nominal Output VoltageV OutV-1010
Measuring RangeÎP MA-13201320
Primary/Secondary RatioV/kA8.33338.3333
Linearity ErrorƐLppm-1515
Offset Voltage (Including Earth Field)VOEppm-1010
Ratio ErrorƐGppm-1010
DC-10Hz Overall accuracy @25°C (=VOE+ƐL + IOE )accƐppm-3535
AC Maximum gain error 10Hz to 1kHz100ppm(0.01%)
Bandwidth (3dB)f3dBkHz300
Operating temperature rangeTa°C-4065
Power supply voltagesUcV±14.25±15.75

Note* Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.