Frequency |
|
Frequency Range |
SSA3021X: 9kHz-2.1GHz. SSA3032X: 9kHz-3.2GHz |
Frequency Resolution |
1Hz |
Frequency Span |
|
Range |
SSA3021X: 0 Hz, 100 Hz to 2.1 GHz. SSA3032X: 0 Hz, 100 Hz to 3.2 GHz |
Accuracy |
± Span / (number of sweep points – 1) |
Internal Reference Source |
|
Reference frequency |
10.000000 MHz |
frequency reference accuracy |
± [(time since last adjustment × frequency aging rate) + temperature stability + calibration accuracy] |
Initial calibration accuracy |
<1 ppm |
Temperature stability |
<1 ppm/year, 0 ℃ ~50 ℃ |
Frequency aging rate |
<0.5 ppm/first year, 3.0 ppm/20 years |
Marker |
|
Marker resolution |
Span / (number of sweep points – 1) |
Marker uncertainty |
± [frequency indication × frequency reference uncertainty + 1% × span + 10% × resolution bandwidth + marker resolution] |
Frequency counter resolution |
1 Hz |
Frequency counter uncertainty |
± [frequency indication × frequency reference accuracy + counter resolution] |
Bandwidths |
|
Resolution bandwidth (-3dB) |
1 Hz~1 MHz*, in 1-3-10 sequence |
Resolution filter shape factor |
< 4.8:1 (60 dB:3 dB), Gaussian-like |
RBW uncertainty |
<5% |
Video bandwidth (-3dB) |
1 Hz ~3 MHz, in 1-3-10 sequence |
VBW uncertainty |
<5% |
Amplitude Characteristics |
|
Measurement range |
DANL to +10 dBm, 100 kHz~1 MHz, preamplifier off
DANL to +20 dBm, 1 MHz~3.2 GHz, preamplifier off |
Reference level |
-100 dBm to +30 dBm, 1 dB steps |
Preamplifier |
20 dB (nom.), 9 kHz~3.2 GHz |
Input attenuation |
0~51 dB, 1 dB steps |
Maximum input DC voltage |
+/- 50 VDC |
Maximum average RF power |
30 dBm, 3 minutes, fc≥10 MHz, attenuation >20 dBm, preamp off |
Maximum damage level |
33 dBm, fc≥10 MHz, attenuation >20 dBm, preamp off |
Phase Noise |
|
Phase noise |
<-95 dBc/Hz @10 kHz offset, <-98 dBc/Hz (typ.)
<-96 dBc/Hz @100 kHz offset,<-97 dBc/Hz (typ.)
<-115 dBc/Hz @1 MHz offset, <-117 dBc/Hz (typ.) |
Level Display |
|
Logarithmic level axis |
10 dB to 200 dB |
Linear level axis |
0 to reference level |
Units of level axis |
dBm, dBmV, dBμV, dBμA, V, W |
Number of display points |
751 |
Number of traces |
4 |
Trace detectors |
Positive-peak, Negative-peak, Sample, Normal, Average (Voltage/RMS/Video) , Quasi-peak (with EMI option) |
Trace functions |
Clear write, Max Hold, Min Hold, View, Blank, Average |
Frequency Response |
|
Preamp Off |
±0.8 dB,
±0.4 dB, (typ.) |
Preamp On |
±0.9 dB,
±0.5 dB, (typ.) |
Error and Accuracy |
|
Resolution bandwidth switching
uncertainty |
10 kHz RBW
Logarithmic resolution ±0.2 dB, liner resolution ±0.01, nominal |
Input attenuation switching
uncertainty |
20 ℃ to 30 ℃ , fc = 50 MHz, preamp off, Relative to 20 dB, 1 to 51 dB attenuation
±0.5 dB |
Absolute amplitude accuracy |
20 ℃ to 30 ℃ , fc = 50 MHz, RBW = 1 kHz, VBW = 1 kHz, peak detector, attenuation = 20 dB, 95th percentile reliability
preamp off ±0.4 dB, input signal -20 dBm
preamp on ±0.5 dB, input signal -40 dBm |
Total amplitude accuracy |
20 ℃ to 30 ℃ , Fc>100 kHz, input signal -50 dBm~0 dBm, RBW = 1 kHz, VBW = 1 kHz, peak detector, attenuation = 20 dB, preamp off, 95th percentile reliability ± 0.7 dB |
RF input VSWR |
input attenuation 10 dB, 1 MHz~3.2 GHz <1.5, nom |
Distortion and Spurious Responses |
|
Second harmonic distortion |
fc≥50 MHz, mixer level -30dBm, attenuation = 0 dB, preamp off, 20 ℃ to 30 ℃ , typ.
-65 dBc |
Third-order intercept |
fc≥50 MHz, two -20 dBm tones at input mixer spaced by 100 kHz, attenuation = 0 dB, preamp off, 20 ℃ to 30 ℃ , typ.
+10 dBm |
1dB Gain Compression |
fc≥50 MHz, attenuation = 0 dB, preamp off, 20 ℃ to 30 ℃ , nom.
>-5 dBm |
Residual response |
input terminated = 50 Ω,attenuation = 0 dB, 20 ℃ to 30 ℃ , typ.
<-90 dBm |
Input related spurious |
Mixer level = -30 dBm, 20 ℃ to 30 ℃
<-65 dBc |
General Specifications |
|
Display |
TFT LCD, 1024×600(waveform area 751×501), 10.1 inch |
Storage |
Internal (Flash) 256 MByte, External (USB storage device) 32 GByte |
Source |
Input voltage range (AC) 100 V~240 V, AC frequency supply 45 Hz~440 Hz, Power consumption 30 W |
Temperature |
Working temperature 0 ℃ to 50 ℃ , Storage temperature -20 ℃ to 70 ℃ |
Humidity |
0 ℃ to 30 ℃ , ≤95% Relative humidity;
30 ℃ to 50 ℃ , ≤75% Relative humidity |
Dimensions |
393 mm×207 mm×116.5 mm (W×H×D) |
Weight |
Contain tracking generator 4.60 kg (10.1 lb) |
Reviews