Rental Kikusui PCR2000WE AC Power Supply / Frequency Converter Single-Phase 2kVA, AC 0 to 310Vrms, 1Hz to 5kHz, DC0 to ±438V

£357.00 (£428.40 inc VAT)

Prices Shown are Rental Price Per Week

Available on back-order

SKU: PCR2000WE-Rental Category:

Description


Kikusui PCR2000WE AC Power Supply / Frequency Converter

The PCR-WE/WE2 is a series of multifunctional switching AC power supplies that combines accurate, high power output and ultra-compact design. The 15 model line-up ranges from 1 kVA to 36 kVA AC/DC with single & 3 phase variable output from 6 kVA and up. The PCR-WE/WE2 also features a regenerative mode*1 that can drastically reduce power consumption and cut the costs of operation. The PCR-WE/WE2 also supports mix-and-match parallel operation*2 up to 144 kVA for large scale test systems. Output frequency up to 5 kHz is also available with all models for critical AC applications in the avionic industries.

Compact Size!
Compared to our previous PWM models, the size of the PCR-WE has been drastically reduced up to 60%. Efficiency has also been increased by approximately 7%, for an overall high efficiency of approximately 85%.

Low Ripple Noise
Extremely low switching noise for a PWM inverter type AC power supply, with ripple noise as low as 0.25 rms achieved with 1 kVA – 6kVA models. The PCR-WE series even boasts similar noise performance to the PCR-LE/LE2 linear amplifier power supply series. The compact, high power design of the PCR-WE/WE2 has been achieved with absolutely no compromises to ripple noise performance.

Output Frequency up to 5 kHZ
Maximum output frequency up to 5 kHz for critical applications in the defense and avionics industries. The frequency performance of the PCR-WE allows for simulation of sharp voltage fluctuations required airborne electronic equipment testing. Furthermore, the compact 6kVA/6U form factor allows for the easy preparation of an automated, one rack testing system without requiring a costly, specialized power source installation space.

LAN, USB, RS232C Standard Digital Interface
The PCR-WE/WE2 series includes a flexible digital interface for users utilizing LAN, USB, and RS232C communication interfaces (GPIB factory option available). LAN connection is LXI compliant, allowing you to monitor and control your device wherever you are via computer, smartphone, or tablet web browser. This feature is particularly important when conducting critical AC tests in anechoic chambers/shield rooms.

Power Line Error Simulation
The PCR-WE/WE2 series can simulate various power line abnormalities such as power outages, voltage drops (dips) and voltage increases (pops). This feature is useful for the testing of power source switches and various electronic devices.

Documentation

Input (AC rms)
ModelPCR1000WEPCR2000WEPCR3000WE2PCR6000WE2PCR12000WE2PCR18000WE2PCR24000WE2PCR30000WE2PCR36000WE2
Nominal input voltage1P2W Input Model: 100 Vac to 120 Vac / 200 Vac to 240 Vac1P2W Input Model: 100 Vac to 120 Vac / 200 Vac to 240 Vac1P2W Input Model: 100 Vac to 120 Vac / 200 Vac to 240 Vac3P3W Input Model: 200 Vac to 240 Vac (3 phase line voltage)
3P4W Input Model: 380 Vac to 480 Vac (3 phase line voltage)
3P3W Input Model: 200 Vac to 240 Vac (3 phase line voltage)
3P4W Input Model: 380 Vac to 480 Vac (3 phase line voltage)
3P3W Input Model: 200 Vac to 240 Vac (3 phase line voltage)
3P4W Input Model: 380 Vac to 480 Vac (3 phase line voltage)
3P3W Input Model: 200 Vac to 240 Vac (3 phase line voltage)
3P4W Input Model: 380 Vac to 480 Vac (3 phase line voltage)
3P3W Input Model: 200 Vac to 240 Vac (3 phase line voltage)
3P4W Input Model: 380 Vac to 480 Vac (3 phase line voltage)
3P3W Input Model: 200 Vac to 240 Vac (3 phase line voltage)
3P4W Input Model: 380 Vac to 480 Vac (3 phase line voltage)
PhaseSingle-phaseSingle-phaseSingle-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phase
Nominal input Frequency50 Hz to 60 Hz50 Hz to 60 Hz50 Hz to 60 Hz50 Hz to 60 Hz50 Hz to 60 Hz50 Hz to 60 Hz50 Hz to 60 Hz50 Hz to 60 Hz50 Hz to 60 Hz
Input frequency range45 Hz to 65 Hz45 Hz to 65 Hz45 Hz to 65 Hz45 Hz to 65 Hz45 Hz to 65 Hz45 Hz to 65 Hz45 Hz to 65 Hz45 Hz to 65 Hz45 Hz to 65 Hz
Apparent power1.4kVA and less2.7kVA and less4kVA and less7.8kVA and less15.6kVA and less23.4kVA and less31.2kVA and less39kVA and less46.8kVA and less
Power factor0.95(TYP)0.95(TYP)0.95(TYP)0.97(TYP) 3P3W input model / 0.95(TYP) 3P4W input model0.97(TYP) 3P3W input model / 0.95(TYP) 3P4W input model0.97(TYP) 3P3W input model / 0.95(TYP) 3P4W input model0.97(TYP) 3P3W input model / 0.95(TYP) 3P4W input model0.97(TYP) 3P3W input model / 0.95(TYP) 3P4W input model0.97(TYP) 3P3W input model / 0.95(TYP) 3P4W input model
Maximum current1P2W input model: 17 A / 8.5 A 32 A / 16 A 48 A / 24 A1P2W input model: 17 A / 8.5 A 32 A / 16 A 48 A / 24 A1P2W input model: 17 A / 8.5 A 32 A / 16 A 48 A / 24 A3P3W Input Model: 27A
3P4W Input Model: 14A
3P3W Input Model: 53A
3P4W Input Model: 28A
3P3W Input Model: 80A
3P4W Input Model: 42A
3P3W Input Model: 106A
3P4W Input Model: 56A
3P3W Input Model: 133A
3P4W Input Model: 70A
3P3W Input Model: 159A
3P4W Input Model: 84A
Holdup time for power interruption10 ms10 ms10 ms10 ms10 ms10 ms10 ms10 ms10 ms
Output
ModelPCR1000WEPCR2000WEPCR3000WE2PCR6000WE2PCR12000WE2PCR18000WE2PCR24000WE2PCR30000WE2PCR36000WE2
AC Voltage
Rating155 V / 310 V155 V / 310 V155 V / 310 V155 V / 310 V155 V / 310 V155 V / 310 V155 V / 310 V155 V / 310 V155 V / 310 V
Setting Range0 V to 157.5 V / 0 V to 315.0 V0 V to 157.5 V / 0 V to 315.0 V0 V to 157.5 V / 0 V to 315.0 V0 V to 157.5 V / 0 V to 315.0 V0 V to 157.5 V / 0 V to 315.0 V0 V to 157.5 V / 0 V to 315.0 V0 V to 157.5 V / 0 V to 315.0 V0 V to 157.5 V / 0 V to 315.0 V0 V to 157.5 V / 0 V to 315.0 V
Setting Resolution0.1 V0.1 V0.1 V0.1 V0.1 V0.1 V0.1 V0.1 V0.1 V
Setting accuracy
(phase voltage)
±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V)±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V)±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V)±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V)±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V)±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V)±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V)±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V)±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V)
Setting accuracy
(Line voltage)
±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V)±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V)±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V)±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V)±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V)±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V)±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V)±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V)±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V)
Maximum
current
Single-phase output10 A / 5 A20 A / 10 A30 A / 15 A60A / 30A120A / 60A180A / 90A240A / 120A300A / 150A360A / 180A
Single-phase three-wire output,
Three-phase output
10A / 5A20A / 10A40A / 20A60A / 30A80A / 40A100A / 50A120A / 60A
Phase1P1P1P2W, 1P3W, 3P4W switchable1P2W, 1P3W, 3P4W switchable1P2W, 1P3W, 3P4W switchable1P2W, 1P3W, 3P4W switchable1P2W, 1P3W, 3P4W switchable1P2W, 1P3W, 3P4W switchable1P2W, 1P3W, 3P4W switchable
Power
capacity
Single-phase output1 kVA2 kVA3kVA6kVA12kVA18kVA24kVA30kVA36kVA
Three-phase output– – –– – –3kVA6kVA12kVA18kVA24kVA30kVA36kVA
Single-phase ―
three-wire output
– – –– – –2kVA4kVA8kVA12kVA16kVA20kVA24kVA
Maximum peak current4 times the maximum output current4 times the maximum output current4 times the maximum output current4 times the maximum output current4 times the maximum output current4 times the maximum output current4 times the maximum output current4 times the maximum output current4 times the maximum output current
Inrush current capacity3 times the rated current (0.07 s)3 times the rated current (0.07 s)3 times the rated current (0.07 s)1.4 times the rated current (0.5 s)1.4 times the rated current (0.5 s)1.4 times the rated current (0.5 s)1.4 times the rated current (0.5 s)1.4 times the rated current (0.5 s)1.4 times the rated current (0.5 s)
Load power factor0 to 1 (leading or lagging)0 to 1 (leading or lagging)0 to 1 (leading or lagging)0 to 1 (leading or lagging)0 to 1 (leading or lagging)0 to 1 (leading or lagging)0 to 1 (leading or lagging)0 to 1 (leading or lagging)0 to 1 (leading or lagging)
Frequency
Setting range1 Hz to 5 kHz  (5 kHz -3dB, <40 Hz derating required)1 Hz to 5 kHz  (5 kHz -3dB, <40 Hz derating required)1 Hz to 5 kHz  (5 kHz -3dB, <40 Hz derating required)1 Hz to 5 kHz  (5 kHz -3dB, <40 Hz derating required)1 Hz to 5 kHz  (5 kHz -3dB, <40 Hz derating required)1 Hz to 5 kHz  (5 kHz -3dB, <40 Hz derating required)1 Hz to 5 kHz  (5 kHz -3dB, <40 Hz derating required)1 Hz to 5 kHz  (5 kHz -3dB, <40 Hz derating required)1 Hz to 5 kHz  (5 kHz -3dB, <40 Hz derating required)
Resolution0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz)0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz)0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz)0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz)0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz)0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz)0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz)0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz)0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz)
Accuracy±0.01 %, Temperature coefficient : ±0.005 %/°C±0.01 %, Temperature coefficient : ±0.005 %/°C±0.01 %, Temperature coefficient : ±0.005 %/°C±0.01 %, Temperature coefficient : ±0.005 %/°C±0.01 %, Temperature coefficient : ±0.005 %/°C±0.01 %, Temperature coefficient : ±0.005 %/°C±0.01 %, Temperature coefficient : ±0.005 %/°C±0.01 %, Temperature coefficient : ±0.005 %/°C±0.01 %, Temperature coefficient : ±0.005 %/°C
Phase
Resolution– – –– – –0.1°(1 Hz to 500 Hz), 1°(500 Hz to 4 kHz), 2°(4 kHz or more)0.1°(1 Hz to 500 Hz), 1°(500 Hz to 4 kHz), 2°(4 kHz or more)0.1°(1 Hz to 500 Hz), 1°(500 Hz to 4 kHz), 2°(4 kHz or more)0.1°(1 Hz to 500 Hz), 1°(500 Hz to 4 kHz), 2°(4 kHz or more)0.1°(1 Hz to 500 Hz), 1°(500 Hz to 4 kHz), 2°(4 kHz or more)0.1°(1 Hz to 500 Hz), 1°(500 Hz to 4 kHz), 2°(4 kHz or more)0.1°(1 Hz to 500 Hz), 1°(500 Hz to 4 kHz), 2°(4 kHz or more)
Accuracy– – –– – –Within 120°±(0.4°+2.5 μs) Within (120°±(0.4°+fo×0.9×10-3°)) fo : frequency [kHz]Within 120°±(0.4°+2.5 μs) Within (120°±(0.4°+fo×0.9×10-3°)) fo : frequency [kHz]Within 120°±(0.4°+2.5 μs) Within (120°±(0.4°+fo×0.9×10-3°)) fo : frequency [kHz]Within 120°±(0.4°+2.5 μs) Within (120°±(0.4°+fo×0.9×10-3°)) fo : frequency [kHz]Within 120°±(0.4°+2.5 μs) Within (120°±(0.4°+fo×0.9×10-3°)) fo : frequency [kHz]Within 120°±(0.4°+2.5 μs) Within (120°±(0.4°+fo×0.9×10-3°)) fo : frequency [kHz]Within 120°±(0.4°+2.5 μs) Within (120°±(0.4°+fo×0.9×10-3°)) fo : frequency [kHz]
DC
voltage
Rating-219 V to +219 V / -438 V to +438 V-219 V to +219 V / -438 V to +438 V-219 V to +219 V / -438 V to +438 V-219 V to +219 V / -438 V to +438 V-219 V to +219 V / -438 V to +438 V-219 V to +219 V / -438 V to +438 V-219 V to +219 V / -438 V to +438 V-219 V to +219 V / -438 V to +438 V-219 V to +219 V / -438 V to +438 V
Setting range-222.5 V to +222.5 V / -445.0 V to +445.0 V-222.5 V to +222.5 V / -445.0 V to +445.0 V-222.5 V to +222.5 V / -445.0 V to +445.0 V-222.5 V to +222.5 V / -445.0 V to +445.0 V-222.5 V to +222.5 V / -445.0 V to +445.0 V-222.5 V to +222.5 V / -445.0 V to +445.0 V-222.5 V to +222.5 V / -445.0 V to +445.0 V-222.5 V to +222.5 V / -445.0 V to +445.0 V-222.5 V to +222.5 V / -445.0 V to +445.0 V
Resolution0.1 V0.1 V0.1 V0.1 V0.1 V0.1 V0.1 V0.1 V0.1 V
Accuracy±(0.05 % of setting +0.1 V)±(0.05 % of setting +0.1 V)±(0.05 % of setting +0.1 V)±(0.05 % of setting +0.1 V)±(0.05 % of setting +0.1 V)±(0.05 % of setting +0.1 V)±(0.05 % of setting +0.1 V)±(0.05 % of setting +0.1 V)±(0.05 % of setting +0.1 V)
Maximum current10A / 5A20A / 10A30A / 15A60A / 30A120A / 60A180A / 90A240A / 120A300A / 150A360A / 180A
Power capacity1kW2kW3kW6kW12kW18kW24kW30kW36kW
Efficiency82 %(TYP)82 %(TYP)82 %(TYP)85 %(TYP)85 %(TYP)85 %(TYP)85 %(TYP)85 %(TYP)85 %(TYP)

Note* Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.