Kikusui TOS5302 AC Flash Tester / HiPot plus Insulation Resistance Tester 0-5kV(AC) 25-1000V(IR) AC 0-100mA (200mA S/C)

£2164.00 (£2,596.80 inc VAT)

1 in stock (can be backordered)

Availability: Stock models delivered next working day (UK only) for orders placed before 16:30 (Mon - Fri)

SKU: TOS5302 Category:

Description


Kikusui TOS5302 Safety Tester

The Kikusui TOS5302 is a AC withstanding voltage and DC insulation resistance tester. It has an AC output of 5 kV/100 mA (200mA S/C 500VA Capacity) and 25V-1000V (7 steps), 500V or greater, up to 5.00G Insulation Resistance test, the TOS5302 can be used in HiPot/Insulation resistance testing of electronic equipment and electronic parts, based on the requirements of IEC, EN, UL, VDE, JIS, and other international safety standards. Also, the test voltage stability is improved with the adoption of a newly developed switching amplifier. Since the output voltage can be kept constant even when the AC line voltage or frequency changes, consistent testing can be performed, even when the power supply environment is in an unstable region. The TOS5300 is also equipped with a number of features. Rise time/Fall time control, Key lock function and Protection cover for key operation, Equipped with USB interface.

Supplied with..

  • New Calibration Certificate (Traceable to National Standards)
  • Test Leads
  • Mains Lead
  • Operation Information

Features:

  • PWM amplifier system for achieving highly stable output
  • AC withstand voltage test at 5 kV / 100 mA (500 VA)
  • Insulation resistance test: 25 V to 1000 V (7 steps) Insulation resistance test: Measures up to 5.00 GΩ
  • High precision measurement ± 1.5% of reading (Voltmeter 500 V or more, ammeter 1 mA or more)
  • Rise time / Fall time control
  • Key lock & operation section cover
  • USB interface installed

Product Videos

Documentation

TOS5301/2 Specifications
ModelTOS5301TOS5302
AC Output Section
Output Range0.05 kV to 5.00 kV0.05 kV to 5.00 kV
Accuracy±(2 % of set + 20 V) when no load is connected±(2 % of set + 20 V) when no load is connected
Setting Range0.00 kV to 5.50 kV0.00 kV to 5.50 kV
Resolution10 V steps10 V steps
Max. rated output500 VA (5 kV/100 mA)500 VA (5 kV/100 mA)
Max. rated voltage5 kV5 kV
Max. rated current100 mA (when the output voltage is 0.5 kV or greater)100 mA (when the output voltage is 0.5 kV or greater)
Transformer rating500 VA500 VA
Output voltage waveformSineSine
DistortionIf the output voltage is 0.5 kV or more: 3 % or less (when no load or a pure resistive load is connected).If the output voltage is 0.5 kV or more: 3 % or less (when no load or a pure resistive load is connected).
Frequency50 Hz or 60 Hz50 Hz or 60 Hz
Accuracy±0.5 % (excluding during voltage rise time)±0.5 % (excluding during voltage rise time)
Voltage regulation10 % or less (when changing from maximum rated load to no load)10 % or less (when changing from maximum rated load to no load)
Input voltage variation±0.3 % (5 kV when no load is connected; power supply voltage: 90 V to 250 V)±0.3 % (5 kV when no load is connected; power supply voltage: 90 V to 250 V)
Short-circuit current200 mA or more (when the output voltage is 1.0 kV or greater)200 mA or more (when the output voltage is 1.0 kV or greater)
Output methodPWM switchingPWM switching
DC Output Section
Output range0.05 kV to 6.00 kV—–
Accuracy±(2 % of set + 20 V) when no load is connected—–
Setting range0.00 kV to 6.20 kV—–
Resolution10 V steps—–
Max. rated output50 W (5 kV/10 mA)—–
Max. rated voltage6 kV—–
Max. rated current10 mA—–
Ripple (TYP)5 kV when no load is connected: 50 Vp-p
Max. Rated Load: 100 Vp-p
—–
Voltage regulation3 % or less (when changing from maximum
rated load to no load)
—–
Short-circuit current (TYP)40 mA (when generation 6 kV output)—–
Discharge featureForced discharge after test completion
(discharge resistance: 125 kΩ)
—–
Start VoltageThe voltage at the start of withstanding voltage tests can be set to 50% of the test voltageThe voltage at the start of withstanding voltage tests can be set to 50% of the test voltage
Limit VoltageThe test voltage upper limit can be set . AC: 0.00 kV to 5.50 kV, DC: 0.00 kV to 6.20 kVThe test voltage upper limit can be set . AC: 0.00 kV to 5.50 kV, DC: 0.00 kV to 6.20 kV
Output voltage monitor featureIf output voltage exceeds the specified value + 350 V or is lower than the specified value – 350 V,
output is turned off, and protective features are activated.
If output voltage exceeds the specified value + 350 V or is lower than the specified value – 350 V,
output is turned off, and protective features are activated.

Note* Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Optional Accessories …