Graphtec GL240 10-Channel Multi-Function Logger

£1058.00 (£1,269.60 inc VAT)

Available on back-order

SKU: GR-GL240 Categories: ,

Description


Graphtec GL240 Multi-Function Logger

The Graphtec GL240 is a 10-channel multi-function (voltage, temperature, humidity, pulse, logic signals) data logger offering sampling periods down to 10ms, 4GB built-in memory expandable to 32GB and a WLAN option for remote monitoring. Standard accessories... Quick start guide, 4GB SD memory card, CD-ROM (user manual & application software), AC adapter and cable, ferrite core. Features:
  • Flexible input system for wide array of applications
  • Wireless LAN capability for remote monitoring and remote datalogging system
  • Extended memory capacity using SD memory card
  • Maximum sampling interval of up to 10ms

Documentation

Main Unit Specifications
Number of analogue input channels 10 Channels
External input/output
Input Trigger or Sampling (1 channel), Logic/Pulse (4 channels)
Output Alarm (4 channels)
Sampling interval 10 ms to 1 hour (10ms to 50ms: voltage only) *4, External signal
Time scale of waveform display 1sec. to 24 hour /division
Trigger, Alarm function
Trigger action Start or stop capturing data by the trigger
Repeat action Off, On (auto rearmed)
Trigger source Start: Off, Measured signal, Alarm, External, Clock, Week or Time
Stop: Off, Measured signal, Alarm, External, Clock, Week or Time
Condition Setting Combination: OR or AND
Analog signal: Rising (High), Falling (Low), Window-in, Window-out
Logic signal: Pattern (combination of each input signal in high or low)
Pulse (number of count): Rising (High), Falling (Low), Window-in, Window-out
Alarm output Outputs a signal when alarm condition occurs in the input signal *5
Pulse input function
Rotation count
(RPM)
Counts the number of pulses per sampling interval and converts to rpm
(rotations per minute), Number of pulses for one rotation may be set to
50, 500, 5000, 50k, 500k, 5M, 50M, 500M rpm/F.S. (rpm./Full Scale)
Accumulating
count
Accumulates the number of pulses from the start of measurement
50, 500, 5000, 50k, 500k, 5M, 50M, 500M C/F.S. (Counts/Full Scale)
Instant count Counts the number of pulses per sampling interval
50, 500, 5000, 50k, 500k, 5M, 50M, 500M C/F.S. (Counts/Full Scale)
Maximum number of pulse inputs Maximum input frequency : 50kHz
Maximum number of count : 50kC/sampling (16-bit counter)
Calculation function
Between channels Addition, Subtraction, Multiplication, and Division for analogue input
Statistical Select two calculations from Average, Peak, Maximum, Minimum, RMS
Search function
Search for analogue signal levels, values of logic or pulse or alarm point
in captured data
Interface to PC USB (Hi-speed), WLAN (using B-568 option)
Storage device
Internal Built-in 4GB Flash Memory *6
External One SD card slot (Support SDHC memory card, up to 32GB) *7
Saved contents Captured data, Setting conditions, Screen copy
Back up recording data function
Backup interval *8 Off, 1, 2, 6, 12, 24 hour(s)
Backup file destination *8 SD memory card or FTP server
Data format *8 GBD (binary) or CSV (test)
Check-sum function (Verifies data file) OFF: Not adding check-sum code to data file.
ON: Adding check-sum code to data file. Check-sum code is verified when replaying data on the GL unit or GL-Connection software.
Capturing mode Mode: Normal, Ring, Relay
Ring: Saves most recent data (Number of captured data: 1000 to 2000000 points) *9
Relay: Saves data to multiple files without losing data until data capturing is stopped
Replay Data Replays captured data that was saved in the GL240 (in GBD or CSV format)
Scaling (Engineering unit) function Measured value can be converted to the specified engineering unit
• Analogue voltage: Converts using four reference points (gain, offset)
• Temperature: Converts using two reference points (offset)
• Pulse count: Converts using two reference points (gain)
Action during data capture • Displaying past data (using dual display mode (Current + Past data))
• Hot-swapping the SD memory card
• Saving data in between cursors
Display
Size 4.3-inch TFT colour LCD (WQVGA: 480 x 272 dots)
Language English, French, German, Chinese, Korean, Russian, Spanish, Japanese
Information *10 Waveform in Y-T with digital values, Waveform only, Digital value, Digital values
and statistics values
Operating environment 0 to 45 ºC, 5 to 85 % RH (non condensed)
(When operating with battery pack 0 to 40 ºC, charging battery 15 to 35 ºC)
Power source
AC adapter 100 to 240 V AC, 50/60 Hz (1 pc of adapter is attached as standard accessory)
DC power 8.5 to 24 V DC (DC drive cable (option B-514) is required)
Battery pack Mountable battery pack (battery pack (option B-569): 7.2V DC, 2900mAh)
Power consumption Max. 36 VA
External dimensions (W x D x H
in mm, Excluding projections)
Approx.194 x 121 x 46 (with the cover)
Weight Approx. 634 g (the cover is attached)

Note*

Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.

Optional Accessories …

  • Graphtec B-569 Battery Pack

    £141.75
    Add to basket
  • Graphtec B-513 Input / Output Cable

    £99.75
    Add to basket
  • Graphtec B-551-10 Shunt Resistor (10 pack)

    £284.55
    Add to basket
  • Graphtec AF1200 Storage Case

    £126.00
    Add to basket
  • Graphtec ACADP-20 AC Power Adapter

    £120.75
    Add to basket
  • Graphtec B-568 Wireless LAN Unit

    £168.00
    Add to basket
  • Graphtec B-530 Humidity Sensor

    £409.50
    Add to basket
  • Graphtec B-514 DC Power Cable

    £63.00
    Add to basket