Rigol DSA875 Front2

Detector use cases

This document highlights some of the common uses for Spectrum Analyser Detector Types....
Rigol DSA875 Front2

S1210 Changing the Workspace path

When the S1210 application is started up a default Workspace path and demo file is created. In the example below the demo Workspace file has been created in C:/Users/ruby/AppData/Local:The S1210 application now shows the associated demo tests that be selected and you can connect to the spectrum analyser by clicking on Device:A different Workspace path can be selected if desired. In the example bel...
Rigol RSA3000 Front

How to Load an RSA3000 License Option

Loading a License on an RSA Spectrum Analyzer is simple.First, you receive the PDF file with the License key to install:Enter the license Key and the Instrument serial number into the websitehttps://licenseen.rigol.com/CustomerService/ProductRight_ENThe verification code is the text to the right.For the RSA instruments this generates a .LIC file that you can load onto a USB...
Rigol RSA3000 Front

EMI Test System Software Getting Started Guide

The Rigol EMI Test System Software is designed to make precompliance scanning with a Rigol DSA family of Spectrum Analyzer easy. This Note is an addendum to the Software User’s Guide. We will set up a prescan, create an amplitude correction table, set limit lines, and perform a final scan. Initial Setup: -    Download the latest version of UltraSigma and the EMI Test System Software from t...
Rigol RSA3000 Front 2

RSA3000, RSA3000E and RSA5000 Alternative Factory Reset and Firmware Upgrade

To reset the RSA3000, RSA3000E and the RSA5000 series to factory settings without using the System menu:1) Power cycle the instrument2) During the boot sequence, quickly and repeatedly press the Back button directly below the keypad on the instrument. To upgrade the firmware on the RSA3000, RSA3000E and the RSA5000 series to factory settings without using the System menu:1) Power cycle the instru...
Rigol RSA3000 Front

RSA3000/3000E/5000 series Open Source Acknowledgment

RIGOL’s RSA3000/3000E/5000 series product uses a number of open source software packages. This document lists the open source software packages used in RSA3000/3000E/5000 series product. https://beyondmeasure.rigoltech.com/acton/attachment/1579/f-be0541d6-bc36-481f-b448-ec059be1b26e/1/-/-/-/-/RSA3000_3000E_5000.pdf...
Rigol RSA3000 Front

How to save a screen shot on the RSA3000 and RSA5000 series at the push of a button.

In order to take a screen shot on the RSA5000, RSA3000 or RSA3000E and have it automatically save to your flash drive follow the steps below.1) Insert flash drive into the instrument and confirm that you can identify it in the File Explore menu.2) Press the Save button3) Press Quicksave Path4) Press Set Path5) Select your flash drive6) Press OK.This will change the quick save buttons path from sav...
Rigol RSA3000 Front 2

S1210 – Using dBuV units successfully

Recent versions of DSA815 Firmware and S1210 software improved the operation of the amplitude units in the software. These versions are: Instrument Firmware – 00.01.19 1210 Software – 05.00.07 On occasion it is still possible to show a data offset due to changing units such as this: This is usually caused by using the instrument from the front panel and setting the amplitude to dBuV manu...
Rigol RSA3000 Front 2

S1210 Final Scan

Once a pre-scan has been done there are 2 ways to add a marker: Double click on the graph in the Measure window. That will create a marker in the Marker Table: Or right click in the marker table area to add a marker: When the markers are set correctly you can right-click on the marker to select Add to Peak Table: Now when you tab to the Peak Table you see the added Peak (in addit...
Rigol RSA3000 Front

Saving and Using Test Setups in EMI mode

Relative measurements are critical in EMI: How does the good board compare to the failed board? How does this look with the CISPR Average detector or against another limit line? Is that coming from the device or the environment? Learn how to create, organise, and open complete test setups for comparison and data recording. Setups can include data traces and instrument configuration details....
Rigol RSA3000 Front 2

EMI Automated Test Setup

Make EMI measurements simpler and faster by automating the process. Combine scans, searches, and interactive measurements. Also conduct further analysis on signals of interest with a single button on the same instrument engineers use for advanced debugging of emissions and signals. ...
Rigol RSA3000 Front

How to use Limit Lines in EMI mode

Access the built in limit lines or configure your own for custom testing. Use the limits and margins when searching for signals of interest or for interactive measurements using multiple detectors....