Compact, Cost-Effective 6.5 GHz VNA Delivering High Performance for R&D and Production
Siglent Technologies has officially announced the launch of the SNA5000X-E Vector Network Analyser, a compact and cost-effective solution engineered to meet essential RF testing requirements without compromising on performance.
Covering a frequency range from 9 kHz to 6.5 GHz and delivering a typical dynamic range of 125 dB, the SNA5000X-E provides accurate, reliable measurements for R&D, education, and production environments.
Key Features and Performance
Positioned as an entry-level model within the SNA5000 series, the SNA5000X-E retains the core performance architecture of the SNA5000A family while offering enhanced value for standard vector network analysis applications.
- Frequency Resolution: Supports 1 Hz resolution.
- IF Bandwidth: Adjustable from 1 Hz to 10 MHz.
- Output Power: Ranges from –40 dBm to +10 dBm.
With its 125 dB typical dynamic range, the instrument maintains excellent measurement stability and accuracy, even in complex RF test scenarios.
-
New

Siglent SNA5003-E 9kHz – 3GHz Vector Network Analyser
£3,689.00Available on back-order
Availability: Stock models delivered next working day (UK only) for orders placed before 16:30 (Mon - Fri)
Add to basket -
New

Siglent SNA5006-E 9kHz – 6.5GHz Vector Network Analyser
£5,413.00Available on back-order
Availability: Stock models delivered next working day (UK only) for orders placed before 16:30 (Mon - Fri)
Add to basket
The SNA5000X-E supports comprehensive S-parameter and differential measurements, alongside integrated time-domain analysis, enhanced time-domain analysis, and spectrum analysis functions.
These capabilities enable engineers to evaluate frequency-domain characteristics, analyse impedance discontinuities, and quickly locate faults within devices under test. A built-in eye diagram function further supports high-speed signal integrity analysis, improving debugging efficiency during development.

To address fixture-induced measurement errors commonly encountered in RF testing, the SNA5000X-E incorporates automatic fixture removal, port extension, de-embedding, and impedance conversion functions. These tools effectively compensate for cable delay and loss, minimising systematic errors and ensuring high confidence in measurement results.
Design and Usability
Designed for modern laboratories and production lines, the SNA5000X-E features a compact form factor with an instrument depth of only 12.6 cm and a weight of less than 5.4 kg. This significantly reduces workspace requirements compared to traditional network analysers. The instrument is equipped with a 12.1-inch touchscreen that supports multi-window display and multiple data formats, creating an intuitive and efficient operating experience.

Automation and Integration
For production and automated test environments, the SNA5000X-E offers one-click filter characteristic analysis to quickly obtain key parameters such as insertion loss and bandwidth. It also supports:
- Custom formula operations
- Remote control via SCPI and WebServer
- Seamless integration into automated systems
These features help to standardise and streamline testing workflows.

By returning to the fundamentals of vector network analysis, the SNA5000X-E combines essential performance, intelligent operation, and compact design in an economical solution. It provides a reliable, one-stop platform for applications ranging from R&D validation to batch quality inspection, enabling engineers to achieve professional RF measurement capability with optimised investment.
Product Specifications Table
| Model | SNA5003X-E | SNA5006X-E |
|---|---|---|
| Frequency range | 9 kHz– 3 GHz | 9 kHz- 6.5 GHz |
| Ports | 2 | |
| Frequency resolution | 1 Hz | |
| Level resolution | 0.05 dB | |
| Range of IFBW | 1 Hz ~ 10 MHz | |
| Number of points | 2 ~ 20001 | |
| Setting range of output level | -40 dBm ~ +10 dBm | |
| Dynamic range | 125 dB (typ.) | |
| Types of calibration | Response calibration, Enhanced Response calibration, Full-one port calibration, Full-two port calibration, TRL calibration | |
| Types of measurement | Scattering-parameter measurement, differential-parameter measurement, receiver measurement, time-domain parameter analysis, impedance conversion, fixture simulation, adapter removal/insertion, enhanced time-domain parameter analysis (TDR), spectrum analysis *Note: Some of these are paid options. | |
| Bias-Tees | Support | |
| Interface | LAN, USB Device, USB Host (USB-GPIB) | |
| Remote control | SCPI/ Labview/ IVI based on USB-TMC/ VXI-11/ Socket/ Telnet/ WebServer | |
| Display | 12.1-inch touch screen | |
| Video output | HDMI | |
How to Shop:
- Online: Browse our collection directly on our website. https://telonic.co.uk/
- Contact Us: For more information, reach out to our sales team at https://telonic.co.uk/contact/





































































































FREE SHIPPING £75+
CELEBRATING 50+ YEARS
PRICE MATCH GUARANTEE