The SNA5003-E VNA, included in the SIGLENT SNA5000X-E series of Vector Network Analysers, has a frequency range of 9 kHz to 3 GHz and supports 2-port scattering-parameter, differential-parameter, and time-domain parameter measurements. The SNA5000X-E series of VNAs is effective instrumentation for determining the Q-factor, bandwidth, and insertion loss of a filter. They feature impedance conversion, movement of the measurement plane, fixture simulation, and adapter removal/insertion adjustments. The VNAs have five sweep types: Linear-Frequency mode, Log-Frequency mode, Power-Sweep mode, CW-Time mode, and Segment-Sweep mode. The SNA5000X-E series VNAs also support scattering-parameter correction for SOLT, SOLR, TRL, Response, and Enhanced Response, providing increased flexibility in R&D and manufacturing applications.
Key Features
Frequency range: 9 kHz –3 GHz
Frequency resolution: 1 Hz
Level resolution: 0.05 dB
Range of IFBW: 1 Hz~10 MHz
Setting range of output level: -40 dBm ~ +10 dBm
Dynamic range: 125 dB(typ.)
Types of calibration: Response calibration, Enhanced Response calibration, Full-one port calibration, Full-two port calibration, TRL calibration
Remote control: SCPI/ Labview/ IVI based on USB-TMC / VXI-11 / Socket /Telnet / WebServer
12.1-inch touch screen
Video output: HDMI
Applications
RF signal analysis and troubleshooting
Spectrum monitoring and interference detection
Wireless communication testing (Wi-Fi, Bluetooth, cellular)
EMI/EMC pre-compliance testing
Broadcast and audio signal analysis
Radar and satellite signal analysis
Component and circuit design validation
Production testing and quality control
Educational and research laboratory use
Field service and maintenance diagnostics
Product Images
Segment Sweep
User-Friendly Interface
Multi-Window & Multi-Trace Display
Formula Editor
Data Analysis
Trace Operations
×
Optimizing Speed and Accuracy
Dynamically optimize scan paths with tailored excitation conditions.
Efficient operation mode, double-click to directly edit parameters, manage with a visual list.
Fewer scan points should be set within the passband, with larger IFBW to reduce sweep time.
More scan points should be set outside the passband, with smaller IFBW to enhance measurement accuracy.
Flexible parameter configuration, supporting division of sweep segments by frequency sub-sweeps, with independent settings for points / frequency range / IF bandwidth per segment.
Virtual Keypad
Operate the instrument without using front‑panel function keys.
Information Display Area
Tap to quickly configure corresponding parameters.
Screensavers
Supports energy‑saving sleep mode with customizable hibernation time for reduced power consumption.
Graffiti Function
Draw graphics and mark information to help users focus better.
Theme Management
Flexibly adjust trace thickness, XY‑axis font styles, grid lines, etc.
Color Setting
Independently set colors for current/historical traces, grid lines, axes, etc.
Multi-window Display
Supports up to 256 channels
Supports up to 256 measurement windows
Each window can display 64 test traces at the same time
Each window can display different measurement formats with independent cursor functions.
The simultaneous display of multiple data formats is helpful to understand DUT from different angles.
Flexible Formula Editor Function
Built-in rich library of common and advanced functions.
User-friendly parameter hints.
Allows input of algebraic formulas using standard mathematical operators and functions, and references data available within the VNA.
Trace Statistics
Automatically displays the mean, standard deviation, and peak-to-peak values of the current active trace, enabling users to quickly read measurements.
Allows setting the statistical range to the full span or a user-defined span.
Useful for testing in-band indicators of band-limited devices such as filters.
Impedance Conversion and Matching
Converts the S-parameters of the current trace to the desired parameter mode.
Supports 8 conversion types.
Enables flexible adjustment of port impedance to adapt to fixtures with different interface standards.
Data / Memory
Supports saving the current data trace in memory.
Facilitates comparison between current and historical data.
Three display modes: data traces only, memory traces only, or both data and memory traces simultaneously.
Four mathematical operations for data and memory traces:
Data / Memory, Data * Memory, Data + Memory, Data - Memory.
We use cookies that are needed to make this website work. With your permission we would also like to use cookies to understand how the site is used and to see which of our adverts bring people here. You can accept all, reject all or choose which to allow, and you can change your mind at any time.
Choose which cookies we can use. Strictly necessary cookies are always on because the website cannot work without them. Everything else is off until you switch it on.
Your browser is sending a Global Privacy Control signal. Marketing cookies stay off unless you switch them on here or choose "Accept all".
Strictly necessary
Always on
Needed for the website to work, for example to keep you signed in, remember your basket, keep the site secure and remember your cookie choices. These cannot be switched off.
Show 1 cookie
Cookie
Set by
Purpose
Kept for
jgwm_cookie_consent
This website
Remembers your cookie choices so we do not ask again on every page.
6 months
Analytics
Help us understand how visitors use the website, for example which pages are popular and how people find us, so we can improve it.
Marketing and advert measurement
Let us see which advert, campaign or website brought you here and whether your visit led to an enquiry or order, so we know which adverts work. Advertising partners may also use them to show you relevant adverts on other websites.