Model | TOS5200 |
AC Output Section | |
Output Range | 0.05 kV to 5.00 kV |
Setting Accuracy | ± (2 % of set + 20 V) [at no load] |
Setting Range | 0.00 kV to 5.50 kV |
Resolution | 10 V STEP |
Max. rated output | 500 VA (5 kV/100 mA) |
Max. rated voltage | 5kV |
Max. rated current | 100 mA [output voltage 0.5 kV or higher] |
Transformer rating | 500 VA |
Output voltage waveform | Sine |
Distortion | If the output voltage is 0.5 kV or more: 3 % or less (when no load or a pure resistive load is connected) |
Crest factor | Within √2 ± 3 % (output voltage 800 V or higher, at no load) |
Frequency | 50 Hz or 60 Hz |
Accuracy | ± 0.5 % (excluding during voltage rise time) |
Voltage regulation | 10 % or less (when changing from maximum rated load to no load) |
Input voltage variation | ±0.3 % (5 kV when no load is connected; power supply voltage: 90 V to 250 V) |
Short-circuit current | 200 mA or more (when the output voltage is 1.0 kV or greater) |
Output method | PWM switching |
Start voltage | The voltage at the start of withstanding voltage tests can be set to 50 % of the test voltage. |
Limit voltage | The test voltage upper limit can be set . AC: 0.00 kV to 5.50 kV |
Output voltage monitor feature | If output voltage exceeds the specified value + 350 V or is lower than the specified value – 350 V, output is turned off, and protective features are activated. |
Voltmeter (Digital) | |
Measurement range | 0.000 kV to 6.500 kV AC |
Display | □.□□□ kV |
Accuracy | V < 500 V: ± (1.5 % of reading + 20 V), V ≥ 500 V: ±1.5 % of reading |
Response | True rms, Average value response/rms display switchable |
Hold feature | After a test is finished, the measured voltage is retained until the PASS or FAIL judgment is cleared |
Ammeter (Digital) | |
Measurement range | 0.00 mA to 110 mA |
Display | i < 1 mA 1 mA ≤ i < 10 mA 10 mA ≤ i < 100 mA 100 mA ≤ i □.□□□ mA □.□□□ mA □□.□□ mA □□□.□ mA |
Accuracy | 1.00 mA ≤ i: ± (1.5 % of reading), i < 1.00 mA: ± (1.5 % of reading + 30 μA) |
Response | True rms/ Mean-value response rms display Can be switched |
Hold feature | After a test is finished, the measured current value is retained until the PASS judgment is cleared. |
General Specification | |
---|
Display | LCD: LED back custom indicators |
Environment | |
Installation location | Indoors, at a height of up to 2000 m |
Spec guaranteed range temperature/humidity | 5 °C to 35 °C (41 °F to 95 °F)/20 %rh to 80 %rh (no condensation) |
Operating range temperature/humidity | 0 °C to 40 °C (32 °F to 104 °F)/20 %rh to 80 %rh (no condensation) |
Storage range temperature/humidity | -20 °C to 70 °C (-4 °F to 158 °F)/90 %rh or less (no condensation) |
Power supply | |
Nominal voltage range (allowable voltage range) | 100 VAC to 240 VAC (90 VAC to 250 VAC) |
Power consumption | 100 VA or less, 800 VA max. |
Allowable frequency range | 47 Hz to 63 Hz |
Insulation resistance (between AC LINE and the chassis) | 30 MΩ or more (500 VDC) |
Withstanding voltage (between AC LINE and the chassis) | 1500 Vac, 1 minute |
Earth continuity | 25 Aac, 0.1 Ω or less |
Dimensions | 320 (12.6″) (330(12.99″)) W × 132(5.2″) (150(5.91″)) H × 350(13.78″) (420(16.54″)) D |
Weight | Approx. 14 kg (30.9 lbs) |