Kikusui TOS5200 AC Flash Tester / HiPot Tester 0-5000V 0-100mA (200mA S/C)

£1202.00 (£1,442.40 inc VAT)

2 in stock (can be backordered)

Availability: Stock models delivered next working day (UK only) for orders placed before 16:30 (Mon - Fri)

SKU: TOS5200 Categories: ,

Description


Kikusui TOS5200 Safety Tester

TOS5200 0-5kV AC Flash Tester features 500 VA capacity and 200 mA short circuit current output capability. Equipped with the PWM amplifier, the TOS5200 can provide a stable & reliable output without being affected by the AC power line. Therefore, it is a perfect solution for safety testing electronic equipment or devices complied to IEC, EN, UL, VDE and JIS etc. requirements.
As TOS5200 covers most of features of our advanced model for AC HiPot Test, it has a superb cost / performance ratio for those who need 200 VA or 500 VA capacity, or both. Also comes equipped the Interlock function together with other safety features.

Supplied with..

  • New Calibration Certificate (Traceable to National Standards)
  • Test Leads
  • Mains Lead
  • Operation Information.

Features:

  • High stability.
  • 5kV / 100mA (500VA) AC withstand Voltage
  • High-precision measurement ± 1.5% of reading
  • Rise time / fall time control
  • Key lock & operation cover
  • USB, RS-232C interface equipped

Documentation

TOS5200 Specifications
ModelTOS5200
AC Output Section
Output Range0.05 kV to 5.00 kV
Setting Accuracy± (2 % of set + 20 V) [at no load]
Setting Range0.00 kV to 5.50 kV
Resolution10 V STEP
Max. rated output500 VA (5 kV/100 mA)
Max. rated voltage5kV
Max. rated current100 mA [output voltage 0.5 kV or higher]
Transformer rating500 VA
Output voltage waveformSine
DistortionIf the output voltage is 0.5 kV or more: 3 % or less (when no load or a pure resistive load is connected)
Crest factorWithin √2 ± 3 % (output voltage 800 V or higher, at no load)
Frequency50 Hz or 60 Hz
Accuracy± 0.5 % (excluding during voltage rise time)
Voltage regulation10 % or less (when changing from maximum rated load to no load)
Input voltage variation±0.3 % (5 kV when no load is connected; power supply voltage: 90 V to 250 V)
Short-circuit current200 mA or more (when the output voltage is 1.0 kV or greater)
Output methodPWM switching
Start voltageThe voltage at the start of withstanding voltage tests can be set to 50 % of the test voltage.
Limit voltageThe test voltage upper limit can be set . AC: 0.00 kV to 5.50 kV
Output voltage monitor featureIf output voltage exceeds the specified value + 350 V or is lower than the specified value – 350 V,
output is turned off, and protective features are activated.
Voltmeter (Digital)
Measurement range0.000 kV to 6.500 kV AC
Display□.□□□ kV
AccuracyV < 500 V: ± (1.5 % of reading + 20 V), V ≥ 500 V: ±1.5 % of reading
ResponseTrue rms, Average value response/rms display switchable
Hold featureAfter a test is finished, the measured voltage is retained until the PASS or FAIL judgment is cleared
Ammeter (Digital)
Measurement range0.00 mA to 110 mA
Displayi < 1 mA           1 mA ≤ i < 10 mA             10 mA ≤ i < 100 mA                 100 mA ≤ i
□.□□□ mA          □.□□□ mA                        □□.□□ mA                                    □□□.□ mA
Accuracy1.00 mA ≤ i: ± (1.5 % of reading), i < 1.00 mA: ± (1.5 % of reading + 30 μA)
ResponseTrue rms/ Mean-value response rms display Can be switched
Hold featureAfter a test is finished, the measured current value is retained until the PASS judgment is cleared.
General Specification
DisplayLCD: LED back custom indicators
Environment
Installation locationIndoors, at a height of up to 2000 m
Spec guaranteed range temperature/humidity5 °C to 35 °C (41 °F to 95 °F)/20 %rh to 80 %rh (no condensation)
Operating range temperature/humidity0 °C to 40 °C (32 °F to 104 °F)/20 %rh to 80 %rh (no condensation)
Storage range temperature/humidity-20 °C to 70 °C (-4 °F to 158 °F)/90 %rh or less (no condensation)
Power supply
Nominal voltage range (allowable voltage range)100 VAC to 240 VAC (90 VAC to 250 VAC)
Power consumption100 VA or less, 800 VA max.
Allowable frequency range47 Hz to 63 Hz
Insulation resistance (between AC LINE and the chassis)30 MΩ or more (500 VDC)
Withstanding voltage (between AC LINE and the chassis)1500 Vac, 1 minute
Earth continuity25 Aac, 0.1 Ω or less
Dimensions320 (12.6″) (330(12.99″)) W × 132(5.2″) (150(5.91″)) H × 350(13.78″) (420(16.54″)) D
WeightApprox. 14 kg (30.9 lbs)

Note* Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.