Archive for 2020

Programming Example: SDS Oscilloscope screen image capture using Python

Posted on: December 14th, 2020 by Doug Lovell
14/12/2020
Here is a brief code example written in Python 3.4 that uses a socket to pull a display image (screenshot) from a SIGLENT SDS1000X-E scope via LAN and save it to the local drive of the controlling computer. NOTE: This program saves the picture/display image file in the same directory that the .py file is being run from. It will overwrite any existing file that has the same name. Download Py...

X-Y Display mode on Scopes – additional features with RIGOL DS1000Z-series oscilloscope (DS1074, DS1074Z-S, DS1104Z, DS1104Z-S)

Posted on: December 14th, 2020 by Doug Lovell
14/12/2020
New DS1000Z series offers more in X-Y mode: In this mode, the Rigol DS1074Z oscilloscope changes 2 of the 4 channels from voltage-time display mode to voltage-voltage display mode. The phase deviation between two signals with the same frequency can be easily measured via Lissajous method. The figure b...

Which oscilloscope probe is best for my application

Posted on: December 14th, 2020 by Doug Lovell
14/12/2020
Selecting the correct oscilloscope probe is very important for making quality measurements. If the probe performance is not adequate or if you did not select the proper probe for your application, you will see distorted or misleading signals on your oscilloscope. There are two kinds of probes, passive and active. Active probes requires power while passive probe do not. For general-purpose measurem...

Using a Rigol product key to generate a Rigol software licence code.

Posted on: December 14th, 2020 by Doug Lovell
14/12/2020
Please note... You must enter the product key exactly as it appears on the certificate. The serial number is made up of capital letters and numbers only - There are no lower case letters and no spaces. Please take care when entering the serial number! If you enter an incorrect but valid serial number, the generated software licence code will not b...

RIGOL scope has a message on screen saying WAIT (in green). All channels ON but I see no signal being displayed. Is this effect to do with triggering?

Posted on: December 14th, 2020 by Doug Lovell
14/12/2020
Yes, you’re right: a WAIT status message is normal behaviour for the Trigger when the scope is not being given quite the right signal for its trigger to fire: - You’ll probably remember on all analogue scopes, there are at least two modes: Auto and Normal (sometimes also Single). - Normal is where the trace waits for each trigger before it starts to trace across the screen (we all remember t...

How can I use Ultra Sigma to grab data from my RIGOL Scope? E.g. CSV file for viewing in Excel?

Posted on: December 14th, 2020 by Doug Lovell
14/12/2020
First of all, install and run Ultra Sigma, - Then make sure you can see your scope (Type shown in the Instruments window of Ultra Sigma) - AND that the scope response with its serial number to a *IDN? command. (Rt-click on instrument and choose SCPI Panel Control window, then click Send&Receive a *IDN?) Once this is OK, Change the setting shown as Base to Advanced (U'Sigma setting drop do...

How to measure an RF Amplifier using a DSA-800 Series Spectrum Analyser

Posted on: December 14th, 2020 by Doug Lovell
14/12/2020
Solution: This document provides step-by-step instructions on using the Rigol DSA-800 series of Spectrum Analysers to measure the characteristics of an RF Amplifier. In addition to the DSA-800 Spectrum Analyser, you will need an RF Source, cabling, and adapters. Measure the amplifier 1. Connect the RF generator output to the RF input of the instrument using the appropriate cabling and con...

How do I measure an RF Bandpass filter

Posted on: December 14th, 2020 by Doug Lovell
14/12/2020
This document provides step-by-step instructions on using the Rigol DSA-800 series of Spectrum Analysers to measure the characteristics of an RF Bandpass filter. NOTE: The DSA must have a Tracking Generator to effectively perform the following test. Normalize the trace (Optional) Many elements in an RF signal path can have nonlinear characteristics. In many cases, these nonlinear effects on...

EMC Precompliance: Testing on a budget

Posted on: December 14th, 2020 by Doug Lovell
14/12/2020
Solution: Almost any electronic design slated for commercial use is subject to EMC (Electromagnetic Compatibility) testing. Any company intending to sell  these products into a country must ensure that the product is tested versus specifications set forth by the regulatory body of that country. Here in the US, the FCC specifies rules on EMC testing. CISPR and IEC are also used throughout the worl...

AMK: What do you get with the DSA Advanced Measurement Kit ? (DSA1000-AMK)

Posted on: December 14th, 2020 by Doug Lovell
14/12/2020
Advanced Measurement Functions Option DSA1000-AMK provides plenty of advanced measurement functions including T-Power (Time domain Power), ACP (Adjacent Channel Power), Chan Pwr (Channel Power), OBW (Occupied Bandwidth), EBW (Emission Bandwidth), C/N Ratio, Harmo Dist (Harmonic Distortion), TOI (Third Order Intermodulation) and Pass/Fail. The measure mode can be Single or Continuous and you can c...

Is there an attenuator built-in on RIGOL’s DSA815?

Posted on: December 14th, 2020 by Doug Lovell
14/12/2020
Yes, but you should still take care never to exceed the DSA815's max input power or voltage (+20dBm or 100mW and 50VDC abs. max - pulsed waveforms can easily exceed this e.g. direct from a LISN - see below). The DSA internal attenuator function is variable to give relative 0-30dB and whilst it does not increase the permissible power, it is designed to allow the instrument to optimise its dynamic r...

I just received mine… how can I tell if it’s working OK?

Posted on: December 14th, 2020 by Doug Lovell
14/12/2020
First follow the procedure for Factory Reset. Then check the noise performance is as it should be. You will need a carefully sequence of settings for this… use the quick video tip on our RIGOL pages....

Sub Categories

AC Power Supplies / Frequency Converters Offers & Promotions (1)

Application Notes

Blog (96)

DC Power Supplies Offers & Promotions (6)

Digital Multimeters Offers & Promotions (1)

Digital Oscilloscopes Offers & Promotions (5)

Electronic Loads Offers & Promotions (1)

Events (7)

Knowledge Base AC Power Supplies

Knowledge Base Data Acquisition Systems

Knowledge Base DC Power Supplies

Knowledge Base DG1000 Series (14)

Knowledge Base DG4000 Series (14)

Knowledge Base Digital Multimeters

Knowledge Base Digital Oscilloscopes

Knowledge Base DL3000 Series (2)

Knowledge Base DM3000 Series (21)

Knowledge Base DP700 Series (8)

Knowledge Base DP800 Series (26)

Knowledge Base DS1000 Series (46)

Knowledge Base DS2000 Series (36)

Knowledge Base DSA800 Series (70)

Knowledge Base DSG800 Series (2)

Knowledge Base Electrical Safety Analysers

Knowledge Base Electronic Loads

Knowledge Base M300 Series (2)

Knowledge Base MSO/DS7000 Series (35)

Knowledge Base MSO5000 Series (35)

Knowledge Base MSO8000 Series (32)

Knowledge Base PBZ Series (3)

Knowledge Base PCR-LE Series (3)

Knowledge Base PCR-MA Series (3)

Knowledge Base PCR-WE/WE2 Series (3)

Knowledge Base PLZ-5W Series (3)

Knowledge Base PLZ-5WH Series (3)

Knowledge Base PLZ-5WH2 Series (3)

Knowledge Base PMX-Multi Series (3)

Knowledge Base PWR-01 Series (3)

Knowledge Base RF Signal Generators

Knowledge Base RSA3000 Series (32)

Knowledge Base RSA5000 Series (31)

Knowledge Base SDG1000X Series (10)

Knowledge Base SDG2000X Series (11)

Knowledge Base SDG6000X Series (11)

Knowledge Base SDG800 Series (10)

Knowledge Base SDL1000X Series (5)

Knowledge Base SDM3000 Series (6)

Knowledge Base SDS1000X-E Series (15)

Knowledge Base SDS2000X-E Series (15)

Knowledge Base SDS5000X Series (15)

Knowledge Base SPD1000X (5)

Knowledge Base SPD3000X/X-E Series (6)

Knowledge Base Spectrum Analysers

Knowledge Base SSA3000X Plus Series (2)

Knowledge Base SSA3000X Series (15)

Knowledge Base SSA3000X-R Series (1)

Knowledge Base SSG3000X Series (4)

Knowledge Base SVA1000X Series (13)

Knowledge Base TOS9300 Series (3)

Knowledge Base Waveform Generators

LCR Meters Offers & Promotions (1)

Product Support (1)

RF Signal Generators (1)

Safety Testers Offers & Promotions (1)

Spectrum Analysers Offers & Promotions (4)

Telonic Instruments News (19)

Telonic Offers & Promotions (7)

CLICK TO CALL

0118 9786911
CLICK TO EMAIL