Free Shipping logo FREE SHIPPING £75+
50 years of Telonic Instruments Ltd logo CELEBRATING 50+ YEARS
Price Match logo PRICE MATCH GUARANTEE

Archive for December, 2020

How to check the version of UltraSpectrum software

How to check the version of UltraSpectrum software Start UltraSigma software Select the spectrum analyser that you wish to control by left-clicking on the instrument ID string Right-click and select UltraSpectrum ...

Defective UltraSpectrum display with DSA800 series

If you experience a defective UltraSpectrum display while connected to a DSA800 series spectrum analyser the most likely cause is due to a UltraSpectrum software version mismatch. Software version  00.01.00.27 corrects the issue and can be downloaded from the blue Downloads tab at:...

How can sweep time effect my Spectrum Measurements?

Spectrum analysers can be used to observe modulated signals. But, some settings may have to be adjusted to observe the signals clearly.In this example, we are going to show how the sweep time and selected detector type can effect the displayed data....

EMI Test System Software Getting Started Guide

The Rigol EMI Test System Software is designed to make precompliance scanning with a Rigol DSA family of Spectrum Analyzer easy. This Note is an addendum to the Software User’s Guide. We will set up a prescan, create an amplitude correction table, set limit lines, and perform a final scan. ...

DSA800 Prefix: How to more easily save filenames

The latest revision of firmware (DSA815 00.01.12) has the ability to save a prefix for use with file saves. This can make data entry a bit easier. -    Press SYSTEM > Down arrow to page 2 > Select Name Prefix ...

How do you add a correction file to the S1210 software tool?

Select Tools at the top of the S1210 application window....

How to save a trace as a CSV with the DSA800 Series

To save a trace as a CSV: 1) Insert USB stick into the USB port on the front panel  NOTE: The format of the USB stick must be FAT32  2)    Press STORAGE > ...

RSA3000, RSA3000E and RSA5000 Alternative Factory Reset and Firmware Upgrade

To reset the RSA3000, RSA3000E and the RSA5000 series to factory settings without using the System menu:1) Power cycle the instrument2) During the boot sequence, quickly and repeatedly press the Back button directly below the keypad on the instrument. ...

RSA3000/3000E/5000 series Open Source Acknowledgment

RIGOL’s RSA3000/3000E/5000 series product uses a number of open source software packages. This document lists the open source software packages used in RSA3000/3000E/5000 series product. ...

How to save a screen shot on the RSA3000 and RSA5000 series at the push of a button.

In order to take a screen shot on the RSA5000, RSA3000 or RSA3000E and have it automatically save to your flash drive follow the steps below.1) Insert flash drive into the instrument and confirm that you can identify it in the File Explore menu.2) Press the Save button3) Press Quick...

Booting the DSA800 series Spectrum Analysers from a USB memory stick

If your DSA800 series spectrum analyser does not boot when powered up it may be possible to correct the issue by booting off of a USB memory stick. When the spectrum analyser is powered on you will see a message at the bottom left corner of the display that says: ...

S1210 – Using dBuV units successfully

Recent versions of DSA815 Firmware and S1210 software improved the operation of the amplitude units in the software. These versions are: Instrument Firmware – 00.01.19 1210 Software – 05.00.07 ...

Sub Categories

AC Power Supplies / Frequency Converters Offers & Promotions (1)

Application Notes

Blog (97)

DC Power Supplies Offers & Promotions (6)

Digital Multimeters Offers & Promotions (1)

Digital Oscilloscopes Offers & Promotions (5)

Electronic Loads Offers & Promotions (1)

Events (7)

Knowledge Base AC Power Supplies

Knowledge Base Data Acquisition Systems

Knowledge Base DC Power Supplies

Knowledge Base DG1000 Series (14)

Knowledge Base DG4000 Series (14)

Knowledge Base Digital Multimeters

Knowledge Base Digital Oscilloscopes

Knowledge Base DL3000 Series (2)

Knowledge Base DM3000 Series (21)

Knowledge Base DP700 Series (8)

Knowledge Base DP800 Series (26)

Knowledge Base DS1000 Series (46)

Knowledge Base DS2000 Series (36)

Knowledge Base DSA800 Series (70)

Knowledge Base DSG800 Series (2)

Knowledge Base Electrical Safety Analysers

Knowledge Base Electronic Loads

Knowledge Base M300 Series (2)

Knowledge Base MSO/DS7000 Series (35)

Knowledge Base MSO5000 Series (35)

Knowledge Base MSO8000 Series (32)

Knowledge Base PBZ Series (3)

Knowledge Base PCR-LE Series (3)

Knowledge Base PCR-MA Series (3)

Knowledge Base PCR-WE/WE2 Series (3)

Knowledge Base PLZ-5W Series (3)

Knowledge Base PLZ-5WH Series (3)

Knowledge Base PLZ-5WH2 Series (3)

Knowledge Base PMX-Multi Series (3)

Knowledge Base PWR-01 Series (3)

Knowledge Base RF Signal Generators

Knowledge Base RSA3000 Series (32)

Knowledge Base RSA5000 Series (31)

Knowledge Base SDG1000X Series (10)

Knowledge Base SDG2000X Series (11)

Knowledge Base SDG6000X Series (11)

Knowledge Base SDG800 Series (10)

Knowledge Base SDL1000X Series (5)

Knowledge Base SDM3000 Series (6)

Knowledge Base SDS1000X-E Series (15)

Knowledge Base SDS2000X-E Series (15)

Knowledge Base SDS5000X Series (15)

Knowledge Base SPD1000X (5)

Knowledge Base SPD3000X/X-E Series (6)

Knowledge Base Spectrum Analysers

Knowledge Base SSA3000X Plus Series (2)

Knowledge Base SSA3000X Series (15)

Knowledge Base SSA3000X-R Series (1)

Knowledge Base SSG3000X Series (4)

Knowledge Base SVA1000X Series (13)

Knowledge Base TOS9300 Series (3)

Knowledge Base Waveform Generators

LCR Meters Offers & Promotions (1)

Product Support (1)

RF Signal Generators (1)

Safety Testers Offers & Promotions (1)

Spectrum Analysers Offers & Promotions (4)

Telonic Instruments News (19)

Telonic Offers & Promotions (8)

CLICK TO CALL

0118 9786911
CLICK TO EMAIL