Sampling Modes | Real-Time |
Sampling Rate | 1GSa/s, 200MSa/s |
Averages | N time acquisitions, all channels simultaneously, N is selectable from 2, 4, 8, 16, 32, 64, 128 and 256. |
Input | |
---|
Input Coupling | DC, AC, GND |
Input Impedance | 1MΩ± 2%, in parallel with 15pF± 3pF |
Probe Attenuation Factors | 1X, 5X, 10X, 50X, 100X, 500X,1000X |
Maximum Input Voltage | 400V (DC+AC Peak, 1MΩ input impedance) 40V (DC+AC Peak) |
Time Delay Between Channel (typical) | 500ps |
Horizontal | |
---|
Sample Rate Range | Real-Time: 13.65Sa/s-1GSa/s Equivalent: 13.65Sa/s-25GSa/s |
Waveform Interpolation | Sin(x)/x |
Scan Speed Range | 2ns/div~50s/div, DS1102X 5ns/div~50s/div, DS1052X 1-2-5 Sequence |
Sample Rate and Delay Time | ± 50ppm (over any 1ms time interval) |
Delta Time Measurement Accuracy (Full Bandwidth) | Single-shot: ± (1 sample interval + 50ppm × reading + 0.6 ns) >16 averages: ± (1sample interval + 50ppm × reading + 0.4 ns) |
Vertical | |
---|
A/D Converter | 8-bit resolution, each channel samples simultaneously[2] |
Volts/div Range | 2mV/div~10V/div at input BNC |
Maximum Input | Analog channel maximum input voltage CAT I 300Vrms, 1000Vpk;instantaneous voltage 1000Vpk CAT II 100Vrms,1000Vpk RP2200 10:1:CAT II 300Vrms RP3200 10:1:CAT II 300Vrms RP3300 10:1:CAT II 300Vrms |
Offset Range | ± 40V(200mV-10V), ± 2V(2mV-100mV) |
Analogue Bandwidth | 100MHz (DS1102D,DS1102E) 50MHz (DS1052D, DS1052E) |
Single-shot Bandwidth | 80MHz (DS1102D, DS1102E) 50MHz (DS1052D, DS1052E) |
Selectable Analog Bandwidth Limit (typical) | 20MHz |
Lower Frequency Limit (AC –3dB) | ≤5Hz (at input BNC) |
Rise Time at BNC, typical | <3.5ns, <7ns, On (100M, 50M) respectively |
DC Gain Accuracy | 2mV/div-5mV/div: ± 4% (Sample or Average acquisition mode) 10mV/div-10V/div: ± 3% (Sample or Average acquisition mode) |
DC Measurement Accuracy, Average Acquisition Mode | Average of ≥16 Waveforms with vertical position at zero: ± (DC Gain Accuracy× reading+0.1div+1mV) Average of ≥16 Waveforms with vertical position not at zero: ±[DC Gain Accuracy× (reading+vertical position)+(1% of vertical position) + 0.2div] Add 2mV for settings from 2mV/div to 200 mV/div |
Delta Volts Measurement Accuracy (Average Acquisition Mode) | Delta Volts between any two averages of 16 waveforms acquired under same setup and ambient conditions: ± (DC Gain Accuracy× reading + 0.05 div) |
Trigger | |
---|
Trigger Sensitivity | 0.1div~1.0div (adjustable) |
Trigger Level Range | Internal: ± 5 divisions from center of screen External: ± 1.2V |
Trigger Level Accuracy (typical) applicable for the signal of rising and falling time ≥20ns | Internal: ± (0.3div × V/div)(± 4 divisions from center of screen) External: ± (6% of setting + 200 mV) |
Trigger Offset | Normal mode: pre-trigger (262144/ sampling rate), delayed trigger 1s Slow Scan mode: pre-trigger 6div, delayed trigger 6div |
Trigger Holdoff range | 100ns~1.5s |
Set Level to 50% (Typical) | Input signal frequency ≥50Hz |
Edge trigger slope | Rising, Falling, Rising + Falling |
Trigger condition | (>, <, =) Positive pulse, (>, <, =) negative pulse |
Pulse Width range | 20ns ~10s |
Video standard & line frequency | Support standard NTSC, PAL and SECAM broadcast systems. Line number range: 1~525 (NTSC) and 1~625 (PAL/SECAM) |
Trigger condition | (>, <, =) Positive slope, (>, <, =) negative slope |
Time setting | 20ns~10s |
Trigger on CH1 | Edge, Pulse, Video, Slope |
Trigger on CH2 | Edge, Pulse, Video, Slope |
Trigger mode | D0~D15 select H, L, X, , |
Trigger Type | D0~D15 select H, L, X |
Qualifier | >, <, = |
Time setup | 20ns~10s |
Measure | |
---|
Cursor | Manual mode: Voltage difference between cursors (∆V) Time difference between cursors (∆T) Reciprocal of ∆T in Hertz (1/∆T)Track: Voltage value for Y-axis waveform Time value for X-axis waveformAuto: Cursors are visible for Automatic Measurement |
Auto Measurement | Vpp, Vamp, Vmax, Vmin, Vtop, Vbase, Vavg, Vrms, Overshoot, Preshoot, Freq, Period, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, Delay1→2 , Delay1→2 |
Display | |
---|
Display Type | 5.7 in. (145 mm) diagonal TFT Liquid Crystal Display |
Display Resolution | 320 horizontal × RGB× 234 vertical pixels |
Display Colour | 64K color |
Display Contrast (typical) | 150:1 |
Backlight Brightness (typical) | 300 nit |
I/O | |
---|
Standard Ports | USB Host, USB Device, LAN, AUX Output (TrigOut/PassFail) |
General Specifications | |
---|
Supply Voltage | 100 ~ 240 VACRMS, 45~440Hz, CAT II |
Power Consumption | Less than 50W |
Fuse | 2A, T rating, 250 V |
Ambient Temperature | Operating 10℃~ 40℃, Non-operating -20℃~ +60℃ |
Cooling Method | Fan force air flow |
Humidity | +35℃ or below: ≤90% relative humidity, +35℃~ +40℃: ≤60% relative humidity |
Altitude | Operating 3,000 m or below, Non-operating 15,000 m or below |
Size | W: 303mm, H: 154mm, D: 133mm |
Weight | Without Package: 2.4kg, Packaged: 3.8 kg |
Calibration Interval | The recommended calibration interval is one year |