Microtest 6621-10 Bench LCR Meter

The MICROTEST 6621 LCR Meter offers a broad frequency range, from 10Hz to 30MHz, which is ideal for measuring the impedance characteristics of various components and materials. This versatile device provides a comprehensive set of measured parameters, including impedance (|Z|), admittance (|Y|), phase angle (θ), reactance (X), resistance (R), conductance (G), susceptance (B), inductance (L), dissipation factor (D), quality factor (Q), DC resistance (DCR), capacitance (C), and equivalent series resistance (ESR). Furthermore, it supports a wide array of communication interfaces such as REMOTE, Handler, LAN, USB Host, USB Device, GPIB, and RS-232, ensuring seamless compatibility with automation equipment or human-machine interfaces (PLCs).

Key Features

  • Frequency range: DC, 10Hz to 1/3/5/10/20/30MHz
  • Output Impedance 25Ω/100Ω, switchable
  • Ultra-high measuring speed <3ms
  • Basic accuracy up to ±0.05%
  • Automatic Level Control Function
  • Open circuit/Short circuit/Load Correction Function
  • Built-in DC Bias Voltage ±12V (Option OP-662102)
  • External DC Bias Current Source (Option 6621+ Series)
  • Support Meter Mode and List Mode
  • Display 4 Sets of Parameters at Once
  • Simultaneous AC/DC Measurement
  • Comparator Function and Handler BIN Classification Function
  • Support RS-232/ Handler/ LAN/ USB Host/ USB Device interfaces
  • Supports GPIB Interface (Option OP-662101)
  • Store Setup Files, Measurement Data, and Screenshots via USB
  • Supports PC Software

Documentation

MODEL FREQUENCY
6621-1 10HZ-1MHz
6621-3 10HZ-3MHz
6621-5 10HZ-5MHz
6621-10 10HZ-10MHz
6621-20 10HZ-20MHz
6621-30 10HZ-30MHz
SERIES 6621
Freq Range 10Hz-30MHz
Freq Setting Continuity
Freq Resolution ±0.01%
Freq Output Accuracy 100mHz, 6-bit Frequency Input
Basic Accuracy typical ±0.05%
AC Drive Level Test Signal Voltage Level 10mV – 2Vrms(100Ω)
10mV – 1Vrms(25Ω)
Voltage Minimum Resolution 1mV
Accuracy ALC ON:6%* Voltage ±2mV
ALC OFF:10% * Voltage ±2mV
Test Signal Current Level 200µA – 20mArms
Current Minimum Resolution 10µA
Accuracy ALC ON:6%* Current ± 20µA
ALC OFF:10% * Current ± 20µA
DC Drive Level 1V (fixed)
Output Impedance 25Ω/100Ω (switchable)
Measurement Mode Meter mode, list mode
Measurement Parameters |Z|、|Y|、θ、X、R、G、B、L、D、Q、DCR、C
Test Time (Fastest) < 3mS

Note*

Specifications are liable to change. For the full list of Specifications, please see the product’s datasheet located under the ‘Documentation’ tab.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Mandatory Accessories …

Optional Accessories …