Kikusui PMX35-3E 0-35V 0-3A 105W Programmable Linear DC Power Supply

The Kikusui PMX-E Series combines the low-noise performance of a linear series-dropper power supply with the connectivity required for modern bench and automated testing. Each compact model provides stable constant-voltage (CV) and constant-current (CC) operation, making the series suitable for powering sensitive electronic circuits, evaluating components and integrating into test systems.

LAN, USB and RS-232C interfaces are fitted as standard. The LAN interface allows the power supply to be controlled and monitored through a web browser on a PC, smartphone or tablet, without requiring dedicated software. Analogue external control and output monitoring are also supported for integration with existing equipment.

For standalone testing, the built-in memory sequence function can consecutively output up to three stored presets without a connected PC. Output on/off delay and output-off timer functions provide additional timing control, while selectable bleeder operation, watchdog monitoring and external-control fault detection help users adapt the supply to their load and test requirements. Front-mounted output terminals provide convenient access on the bench, and remote sensing is included on the 18 V and 35 V models to compensate for voltage drop in the load wiring.

Key Features
  • Compact programmable linear DC power supply
  • Stable constant-voltage (CV) and constant-current (CC) operation
  • Low ripple noise from series-dropper regulation
  • LAN, USB and RS-232C communication interfaces fitted as standard
  • Control and monitoring through a web browser over LAN
  • Browser access from PCs, smartphones and tablets
  • Built-in memory sequencing for consecutively outputting up to three presets without a PC
  • Adjustable output on/off delay
  • Output-off timer function
  • Selectable bleeder circuit operation
  • Watchdog and external-control monitoring functions
  • Analogue external control and output monitoring
  • Multiple protection functions
  • Front-mounted output terminals for convenient bench connections
  • Remote sensing on PMX18-2E, PMX18-5E, PMX35-1E and PMX35-3E models
Applications
  • Electronic circuit design and verification
  • Research and development laboratories
  • Powering sensitive analogue and digital circuits
  • Component and device evaluation
  • Production inspection and quality control
  • Automated test equipment and system integration
  • Education and practical electronics training
  • Remote and network-controlled testing
  • Tests requiring timed output control or short standalone sequences

Product Images

Now you can combine up to three waveforms without the PC!
Output can be turned off by upper/lower voltage, upper/lower current, or time settings.
Set a delay between pressing the OUTPUT key and when the output turns on or off. This function is an excellent choice for timing control based on the load’s characteristics.

Product Videos

Documentation

Model PMX18-2E

(Has High-Speed Rise/Fall variant)

PMX18-5E PMX35-1E

(Has High-Speed Rise/Fall variant)

PMX35-3E PMX70-1E PMX110-0.6E PMX250-0.25E PMX350-0.2E PMX500-0.1E
AC input
Rated input rating 100 VAC, 50 Hz / 60 Hz, single phase (117 / 200 / 217 / 234 VAC available as factory options)
Input voltage range ± 10 %
Input frequency range 47 Hz to 63 Hz
Inrush current (MAX) 50 A 60 A 45 A 60 A 65 A 55 A 40 A 55 A 40 A
Power 150 VA 310 VA 150 VA 310 VA 230 VA 210 VA 210 VA 230 VA 170 VA
Output
Rating Output voltage 18.00 V 18.00 V 35.00 V 35.00 V 70.00 V 110.0 V 250.0 V 350.0 V 500.0 V
Output current 2.000 A 5.000 A 1.000 A 3.000 A 1.000 A 0.600 A 0.250 A 0.200 A 0.100 A
Output power 36 W 90 W 35 W 105 W 70 W 66 W 62.5 W 70 W 50 W
Voltage Setting range 0 V to 18.90 V 0 V to 18.90 V 0 V to 36.75 V 0 V to 36.75 V 0 V to 73.50 V 0 V to 115.5 V 0 V to 262.5 V 0 V to 367.5 V 0 V to 525.0 V
Setting resolution *1 1 mV 2 mV 10 mV
Setting accuracy ± (0.2 % of setting + 0.1 % of rating)
Power fluctuation*2 ±1 mV ±1 mV ±3 mV ±3 mV ±5 mV ±7 mV ±15 mV ±25 mV ±30 mV
Load variation*3 ±2 mV ±5 mV ±3 mV ±4 mV ±5 mV ±7 mV ±15 mV ±25 mV ±30 mV
Transient response *4 50 μs 100 μs
Ripple noise (rms) *5 0.5 mV (1 mV) *6 0.5 mV 0.5 mV (1 mV) *6 0.5 mV 1 mV 2 mV 3 mV 5 mV 10 mV
Rise time*7 Rated load ≤ 120 ms (≤ 20 ms) *6 ≤ 120 ms ≤ 120 ms (≤ 20 ms) *6 ≤ 120 ms ≤ 150 ms ≤ 120 ms ≤ 120 ms ≤ 150 ms ≤ 120 ms
No load ≤ 120 ms (≤ 20 ms) *6 ≤ 120 ms ≤ 120 ms (≤ 20 ms) *6 ≤ 120 ms ≤ 150 ms ≤ 120 ms ≤ 120 ms ≤ 150 ms ≤ 120 ms
Fall time *8 Rated load ≤ 50 ms (≤ 20 ms) *6 ≤ 50 ms ≤ 50 ms (≤ 20 ms) *6 ≤ 50 ms ≤ 50 ms ≤ 50 ms ≤ 50 ms ≤ 80 ms ≤ 50 ms
No load ≤ 120 ms (≤ 20 ms) *6 ≤ 120 ms ≤ 120 ms (≤ 20 ms) *6 ≤ 120 ms ≤ 150 ms ≤ 120 ms ≤ 120 ms ≤ 150 ms ≤ 60 ms
Max. remote sensing compensation voltage 0.6 V (one‑way)
Temperature coefficient (TYP) 100 ppm/℃
Current
Setting range 0 A to 2.10 A 0 A to 5.25 A 0 A to 1.05 A 0 A to 3.15 A 0 A to 1.050 A 0 A to 0.630 A 0 A to 0.262 A 0 A to 0.210 A 0 A to 0.105 A
Setting resolution *1 0.1 mA
Setting accuracy ± (0.3 % of setting + 0.1 % of rating)
Power fluctuation*2 ±5 mA ±2 mA ±2 mA ±1 mA ±1 mA ±1 mA
Load variation*3 ±5 mA ±5 mA ±5 mA ±5 mA ±5 mA ±3 mA
Ripple noise (rms) *5 1 mA (2 mA) *6 2 mA 1 mA (2 mA) *6 1 mA 1 mA
Rise time *7 *9 Rated load - (≤ 20 ms) *6 - (≤ 20 ms) *6
Fall time *8 *9 Rated load - (≤ 20 ms) *6 - (≤ 20 ms) *6
Temperature coefficient (TYP) 200 ppm/°C

*1. You can set a value down to 1/10 of the minimum digit by using the SHIFT key and knob together or with a communication command.

*2.100 Vac to 90 Vac or 100 Vac to 110 Vac, fixed load.

*3.For 0 % to 100 % of output voltage or output current.

*4.The amount of time required for the output voltage to return to a value within “rated output voltage ± (0.05 % + 10 mV).” When the load current is changed from 10 % to 100 % of the rated output current.

*5.At rated load. When the measurement frequency bandwidth is 10 Hz to 1 MHz.

*6. The values ​​in parentheses apply to models equipped with the high-speed rising/falling function (factory option).

*7.The time for the output voltage to rise from 10 % to 90 % of the rating when the output is turned on.

*8.The time for the output voltage to fall from 90 % to 10 % of the rating when the output is turned off

*9. The current rise/fall time specifications apply only to models equipped with the high-speed rising/falling function.

Mandatory Accessories …

  • Image of Power cord

    UK Power Cord

    .
    Read more

Optional Accessories …

  • Image of Kikusui tu01 pmx

    Kikusui TU01-PMX Terminal Unit for PMX-A

    £113.00 (£135.60 inc. VAT)

    Available on back-order

    Availability: Stock models delivered next working day (UK only) for orders placed before 16:30 (Mon - Fri)

    Add to basket
  • Image of Kikusui kra

    Kikusui KRA3 Rack Adapter

    £170.00 (£204.00 inc. VAT)

    Available on back-order

    Availability: Stock models delivered next working day (UK only) for orders placed before 16:30 (Mon - Fri)

    Add to basket
  • Image of Kikusui op01 pmx

    Kikusui OP01-PMX Connector Kit for PMX-A

    £30.00 (£36.00 inc. VAT)

    Available on back-order

    Availability: Stock models delivered next working day (UK only) for orders placed before 16:30 (Mon - Fri)

    Add to basket