Micsig CP503 High Frequency 30A AC DC 50MHz Current Probe

£435.00 (£522.00 inc VAT)

Available on back-order

Description


Micsig CP503 AC/DC 30A 50MHz Oscilloscope Probe for measuring direct and alternating current with a current of up to 30 A with a 50 MHz Bandwidth, it can be connected to the oscilloscope through the Micsig UPI connector. It does not require an external power supply.

Features:

  • Dual range selection, easy to measure low current
  • Degaussing and automatic Zero setting
  • Wide bandwidth with superior 1% accuracy (typical)
  • Directly powered by Micsig UPI interface (CP1003/CP503)

 

ModelBandwidthRise TimePower InterfaceRangeOutput SensitivityDC accuracy (typical)
CP50350MHz≤7nsMicsig UPI6A(2X)/ 30A(10X)1V/2A(6A )
1V/10A(30A)
±1%±10mA(6A )
±1%±50mA(30A)
CP1003100MHz≤3.5nsMicsig UPI6A(2X)/ 30A(10X)1V/2A(6A )
1V/10A(30A)
±1%±10mA(6A )
±1%±50mA(30A)
CP503B50MHz≤7nsStandard BNC6A(2X)/ 30A(10X)1V/2A(6A )
1V/10A(30A)
±1%±10mA(6A )
±1%±50mA(30A)
CP1003B100MHz≤3.5nsStandard BNC6A(2X)/ 30A(10X)1V/2A(6A )
1V/10A(30A)
±1%±10mA(6A )
±1%±50mA(30A)

 

Documentation


User Manual CP503/CP1003

Micsig CP503/CP1003 User Manual


Data Sheet CP503/CP1003

Micsig CP503/CP1003 Data Sheet



CP503 Specifications
ModelCP503
Bandwidth50MHz
Current range6A (2X) / 30A (10X)
Output ConnectorPowered BNC / External BNC
Output Sensitivity1V/2A (6A) 1V/10A (30A)
Typical Accuracy1%
Phase Accuracy≤0.8° (45Hz-66Hz)
Temperature CoefficientOperating temp. range + 0.05 × Accuracy Specification /℃ (23℃±5℃)
Conductor Positional AccuracyWithin ±1% (Deviation from the Center)
Influence of External Magnetic Fields1.5% f.s. or below (400A/m,50Hz/60Hz)
Offset Voltage±1mV or below
Max VoltageCAT I 300V

Note* Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.