Black or Green Terminal on a Power Supply
Our power supplies are isolated power supplies. So when you connect to the black negative terminal you have connected your DUT to an isolated channel. Where as if you connect to the…
Read moreFrom the blog
Our power supplies are isolated power supplies. So when you connect to the black negative terminal you have connected your DUT to an isolated channel. Where as if you connect to the…
Read more
The maximum power consumption of DP832/DP832A is 418 Watts.
Read more
The image below shows how quickly the DP700 will turn off its output when it detects that OVP, OCP or OPP has been exceeded. The instrument below shut off its output power…
Read more
The image below shows how quickly the DP800 will turn off its output when it detects that OVP, OCP or OPP has been exceeded. The instrument below shut off its output power…
Read more
DP700 series power supply provides the following options: Trigger: provides the trigger input and output functions. Timer: outputs based on the preset voltage and current values. High Resolution: improves…
Read more
The DP832 is a triple output power supply. CH1 and CH2 are +30V supplies, and CH3 is a 5V supply. To configure the instrument as a +/-30V or lower, you can use the…
Read more
The DP700 series power supply can receive a trigger to enable the output of the supply. Pin 8 of the RS232 interface on the rear panel is used for trigger input, When a low…
Read more
The DP700 series power supply will show a transient voltage on the outputs when the power supply is powered up. Typically the transient voltage will show approximately 400mV p-p over a 200us…
Read more
Options can be added to the non "A" version of the DP800 power supplies to give them the same capabilities as the A version power supplies. To see what options are currently…
Read more
The DP800 series power supply will show a transient voltage on the outputs when the power supply is powered up. Typically the transient voltage will show approximately 400mV p-p over a 200us…
Read more
The DP800 allows the user to create timer functions either directly on the instrument through the timer interface or by loading a timer file onto the instrument. To load the timer file…
Read more
The DP700 series power supply provides a timer function. When the timing output is enabled, the instrument will configure the output voltages and currents based on the preset timer parameters. The edited…
Read moreChoose which cookies we can use. Strictly necessary cookies are always on because the website cannot work without them. Everything else is off until you switch it on.
Your browser is sending a Global Privacy Control signal. Marketing cookies stay off unless you switch them on here or choose "Accept all".
Needed for the website to work, for example to keep you signed in, remember your basket, keep the site secure and remember your cookie choices. These cannot be switched off.
| Cookie | Set by | Purpose | Kept for |
|---|---|---|---|
jgwm_cookie_consent |
This website | Remembers your cookie choices so we do not ask again on every page. | 6 months |
Help us understand how visitors use the website, for example which pages are popular and how people find us, so we can improve it.
Let us see which advert, campaign or website brought you here and whether your visit led to an enquiry or order, so we know which adverts work. Advertising partners may also use them to show you relevant adverts on other websites.