SOURCETRONIC ST2832 LCR Meter

£1609.00 (£1,930.80 inc VAT)

Available on back-order

SKU: ST2832 Category:

Description


Sourcetronic ST2832 LCR Meter

Features:

  • Frequency: 20Hz – 200kHz
  • Basic Accuracy: 0.05%
  • Test parameter: |Z|, |Y|, C, L, D, Q, θ(DEG), θ(RAD), Δ%, DCR
  • Internal 0 – ± 5V/50mA bias source
  • 4.3″ TFT LCD display
  • Interface: RS232, USB, HANDLER, GPIB (optional)
  • Measuring time: 13ms
  • Comparator function

Specification:

  • Soft power switch
  • Max. 200kHz test frequency
  • 6 digit reading resolution
  • 10mVrms-2.0Vrms programmable test level
  • Internal 0 – ± 5V/50mA bias source
  • DCR, 50mV-2V programmable test level, resolution 10μΩ
  • DCR polarity configuration function, particularly for inductance test
  • Highest test speed 13ms/time
  • Selectable 30Ω/100Ω signal source impedance
  • V/I monitor and auto level adjustment function
  • Built-in comparator, 10 bins sorting and count function
  • File storage and program update through U disk
  • RS232, USB, HANDLER, GPIB interface (optional)

    Standard Hardware Accessories

Technical Specification
Model NameST2830ST2832
Basic Measurement AccuracyLCRZ: 0.05%
DCR: 0.1%
Calibration Condition: Warm up time: ≥ 30 s ; Environment temperature: 23±5ºC
Signal voltage: 0.3Vrms – 1Vrms ; Correction: after OPEN, SHORT
Testing cable length: 0 m
LCRZ: 0.05%
DCR: 0.1%
Calibration Condition: Warm up time: ≥ 30 s ; Environment temperature: 23±5ºC
Signal voltage: 0.3Vrms – 1Vrms ; Correction: after OPEN, SHORT
Testing cable length: 0 m
Test signal frequency50Hz-100kHz
34 points
50Hz, 60Hz, 75Hz, 100Hz, 120Hz, 150Hz, 200Hz, 250Hz, 300Hz, 400Hz, 500Hz, 600Hz, 750Hz, 1kHz, 1.2kHz, 1.5kHz, 2kHz, 2.5kHz, 3kHz, 4kHz, 5kHz, 6kHz, 7.5kHz, 10kHz, 12kHz, 15kHz, 20kHz, 25kHz, 30kHz, 40kHz, 50kHz, 60kHz, 75kHz, 100kHz
20Hz-200kHz, 15025 points
Signal source output impedanceSelectable 30Ω, 100Ω, ±1% @1kHzSelectable 30Ω, 100Ω, ±1% @1kHz
DCR test signal level1V DC50mV – 2V DC
Resolution: 0.5mV
DC bias voltage source0V – ±5V
Resolution: 0.5mV,
Accuracy: 1%
0mA – ±50mA
Resolution: 0.5µA
Test parameters|Z|, |Y|, C, L, X, B, R, G, D, Q, θ, DCR|Z|, |Y|, C, L, X, B, R, G, D, Q, θ, DCR
DCR display range0.00001Ω – 99.999MΩ0.00001Ω – 99.999MΩ
LCR parameters display range|Z|, R, X 0.00001Ω — 99.9999MΩ
|Y|, G, B 0.00001μs — 99.9999s
C 0.00001pF — 9.99999F
L 0.00001μH — 99.9999kH
D 0.00001 — 9.99999
Q 0.00001 — 99999.9
θ(DEG) -179.999º — 179.999º
θ(RAD) -3.14159 — 3.14159
Δ% -999.999% — 999.999%
|Z|, R, X 0.00001Ω — 99.9999MΩ
|Y|, G, B 0.00001μs — 99.9999s
C 0.00001pF — 9.99999F
L 0.00001μH — 99.9999kH
D 0.00001 — 9.99999
Q 0.00001 — 99999.9
θ(DEG) -179.999º — 179.999º
θ(RAD) -3.14159 — 3.14159
Δ% -999.999% — 999.999%
Display digits66
Measurement time (≥10 kHz)Fast: 75 meas/sec (13ms)
Medium 11 meas/sec 90 ms)
Slow: 2.7meas/sec 370 ms)
Fast: 75 meas/sec (13ms)
Medium 11 meas/sec 90 ms)
Slow: 2.7meas/sec 370 ms)
Equivalent circuitSerial, ParallelSerial, Parallel
Range modeAuto, HoldAuto, Hold
Trigger modeInternal, Manual, External, BusInternal, Manual, External, Bus
Averaging1 – 255 individual measurements1 – 255 individual measurements
CorrectionOpen, Short, (known) LoadOpen, Short, (known) Load
Math operationDirect reading, difference to set reference value as ΔABS, Δ%Direct reading, difference to set reference value as ΔABS, Δ%
Trigger delay time setting0 – 60.000s, 1ms steps0 – 60.000s, 1ms steps
Step delay time setting0 – 60.000s, 1ms steps0 – 60.000s, 1ms steps
List Sweep10 points list sweep
Frequency, AC voltage/current, internal/ external bias voltage/current can be swept
Each sweep point can be sorted separately.
10 points list sweep
Frequency, AC voltage/current, internal/ external bias voltage/current can be swept
Each sweep point can be sorted separately.
Comparator function10 bins, BIN1–BIN9, NG, AUX
Bin count function
PASS, FAIL front panel or scan fixture LED display
10 bins, BIN1–BIN9, NG, AUX
Bin count function
PASS, FAIL front panel or scan fixture LED display
Built-in StorageInternal 40 LCRZ instrument setting files, 201 times test resultsInternal 40 LCRZ instrument setting files, 201 times test results
USB StorageInstrument setting files , measurement result CSV files, screenshots (GIF format)Instrument setting files , measurement result CSV files, screenshots (GIF format)
InterfaceControl Interface: Handler
Communication Interface: USB DEVICE, RS232C, GPIB (option)
Storage Interface: USB HOST (U-disk storage)
Control Interface: Handler
Communication Interface: USB DEVICE, RS232C, GPIB (option)
Storage Interface: USB HOST (U-disk storage)

Note*

Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.