Rental Kikusui TOS6210 Ground Bond Tester 0-6VAC 6-60A

£126.00 (£151.20 inc VAT)

Prices Shown are Rental Price Per Week

Out of stock

Availability: Stock models delivered next working day (UK only) for orders placed before 16:30 (Mon - Fri)

SKU: TOS6210-Rental Categories: ,

Description


Kikusui Rental TOS6210 Safety Tester

The TOS6210 is a constant current AC Low Ohm tester, the TOS6210 tester extends the maximum test current from 30 A to 60 A, which is demanded by the new standard.
In addition, the tester also lets you judge the acceptability of the device under test based on the drop in voltage, as required in the standard. What’s more, you can preset test conditions of up to 20 different types of safety standards, such as those for information technology equipment, home appliances, medical devices, and measuring instruments, in the memory on the main unit’s panel.
A simple memory call operation allows you to set up a protective earthling or protective bonding continuity test as stipulated in UL60950-1 and other relevant specifications including IEC and JIS standards.
The TOS6210 also features a set of functions that meet the specific needs of testing personnel, such as an offset cancellation function and a memo function that allows you to input calibration dates, production numbers, and other test-related information and read the input information later via the GPIB or RS-232C interface.

Features:

  • Test current value: 6 to 62 A AC / Resistance value: 0.001 to 0.600 ohm
  • Voltage drop-based judgment function
  • Offset cancelling function
  • Stores 100 test conditions in memory
  • Incorporates test conditions into program
  • Contact Check function
  • Equipped with standard GPIB and RS-232C interfaces
  • Equipped with standard test lead (TL12-TOS)
TOS6210 Specifications
ModelTOS6210
Output Block
Current Setting Range6.0 to 62.0 A AC (With respect to resistance resulting in output power of the maximum rated Output or less and an output terminal voltage of 5.4 V or less)
Resolution0.1A
Accuracy± (1% of setting + 0.4A)
Maximum rated output220 VA (at the output terminals)
Distortion factor2% or less (with respect to 0.1 Ω pure resistance load of 20 A or greater)
Frequency50/60 Hz, sine wave (selectable)
Accuracy±200ppm
Open terminal voltage6 Vrms or less
Output methodPWM switching method
Output Ammeter
Measurement range0.0 to 66.0 A AC
Resolution0.1A
Accuracy± (1% of reading + 0.4A)
ResponseMean value response/rms value display (response time: 200 ms)
Holding functionThe current measured at the end of test is held during the PASS or FAIL inteval
Output Voltmeter
Measurement range0.00 to 6.00 V AC
Resolution0.01V
Offset Cancel Function0.00 to 5.40 V (Offset ON/OFF function provided)
Accuracy± (1% of reading + 0.02V)
ResponseMean value response/rms value display (response time: 200 ms)
Holding functionThe voltage measured at the end of test is held during the PASS or FAIL inteval
Ohmmeter
Measurement range0.001 to 0.600 Ω
Resolution0.001 Ω
Offset cancel function0.000 to 0.600 Ω (Offset ON/OFF function provided)
Accuracy± (2% of reading + 0.003 Ω)
Holding functionThe resistance measured at the end of test is held during the PASS or FAIL interval
Environment
Operating environmentIndoor use, Overvoltage Category II
Warranty rangeTemperature: 5° to 35°C

Humidity: 20 %rh to 80 %rh (non condensing)

Operating rangeTemperature: 0° to 40°C

Humidity: 20 %rh to 80 %rh (non condensing)

Storage rangeTemperature: -20° to 70°C

Humidity: 90 %rh or less (non condensing)

AltitudeUp to 2000 m
Power Requirement
Allowable voltage range85 to 250 V AC
Allowable frequency range47 Hz to 63 Hz
Insulation resistance30 MΩ min. (500 V DC), between AC line and chassis
Hipot1390 V AC (2 seconds), between AC line and chassis
Ground Bond25 A AC/0.1 Ω max.

Note* Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.