Kikusui SD009-PCR-LE/WE Power Line Disturbance Immunity Testing Software IEC61000-4

£562.00 (£674.40 inc VAT)

Available on back-order

Description


Kikusui SD009-PCR-LE/WE Power Line Disturbance Immunity Testing Software

“Quick Immunity Sequencer” (model name: SD009-PCR-LE/WE) is an application software for immunity testing with the AC/DC power supply PCR-WE/WEA2 series system, based on the power line disturbance standard (IEC61000-4 Series) for the immunity testing of the EMC standard. Not only can it be used for compliance testing based on the latest standards or for some types of preliminary testing, but the software can be also employed for advance checking in development phases and for immunity margin tests, because it allows extended testing conditions to be set as needed.

Capable of performing compliance testing applied to the IEC61000-4-11, 4-13, 4-14, 4-17, 4-27, 4-28, 4-29, 4-34 or to perform preliminary tests before the standard testing.

List of conformance to the EMC standard tests
✔ :Conforming as standard ▲ :Partially non-conforming ─ :Function not available

 

 

 

 

StandardItemSingle-Phase ConformingThree-Phase Conforming
IEC61000-1-11
Voltage dips, short interruptions and voltage variations
Voltage Dips
Short Interruptions
Voltage Variations
IEC61000-4-13
Harmonics and inter-harmonics
Flat curve
Over swing
Frequency sweep
Odd harmonics the order of which is not a multiple of 3
Odd harmonics the order of which is a multiple of 3
Even harmonics
Interharmonics
Meister curve
IEC61000-4-14
Voltage fluctuation
Voltage fluctuation
Interval
IEC61000-4-17
Ripple on DC input power port
Single-phase rectifier circuit
Three-phase rectifier circuit
IEC61000-4-27
Unbalance in units
Unbalance▲*1
IEC61000-4-28
Variation of power frequency for equipment with 16 A/phase
Frequency variation
IEC61000-4-29
Voltage dips, short interruptions and voltage variations on DC
Voltage dips
Short interruptions▲*3
Voltage variations
IEC61000-4-34
Voltage dips, short interruptions and voltage variations for equipment with input current more than 16 A/phase
Voltage dips▲*2▲*2
Short interruptions▲*2▲*2
Voltage variations

* Immunity testing for units with 16 A/phase except for those required by IEC61000-4-34
*1. Capability of rapid change with 1 µs to 5 µs is required for 110 %, 95.2 %, 93.5 %, 90 %, 87 %, 80 %, 74 %, 71 %, 66 %. Preliminary test is capable since the voltage response of the PCR-WE/WE2 is 55 µs in FAST mode.
*2. The device between the range of 16 A to 75 A requires to have the capability of rapid change with 1 μs to 5 μs. The device exceeding 75 A does not require to have the capability of rapid change with 1μs to 5 μs. (It is relaxed to 1 µs to 50 µs for the device exceeding 75 A.)
*3. Must support output impedance greater than 100 kΩ. The PCR-WE/WE2 output impedance is less than 100 kΩ and therefore designed for preliminary testing purposes.