Tekbox TBEMCL1-CAL EM-Clamp Calibration Fixture

£545.00 (£654.00 inc VAT)

Available on back-order

Request Quote
SKU: TBEMCL1-CAL Categories: , , Brand:

Description


Tekbox TBEMCL1-CAL EM-Clamp Calibration Fixture

The TBEMCL1-CAL is an EM-clamp calibration fixture built in accordance with the corresponding specification in the standard IEC/EN 61000-4-6, Annex A. It is used to calibrate the coupling and decoupling factors and the input impedance of EM-clamps. Furthermore, it is used to set immunity test levels according to IEC/EN 61000-4-6.

Key Specifications
  • Compliance: IEC/EN 61000-4-6, Annex A
  • Nominal frequency range: 150 kHz – 80 MHz
  • Usable frequency range: 10 kHz – 1 GHz
  • Nominal impedance: 248 Ω
  • Impedance range: ~ 230Ω – 260 Ω
  • RF connectors: N-Female
  • Centre conductor height: adjustable, ~ 47 mm – 75 mm
  • Centre conductor material: ⌀ 4 mm, brass, nickel gold plated
  • Spacing between brackets: 652 mm
  • Ground plane dimensions: 1066 x 500 mm
  • Panel material: Aluminium 6061
  • Weight: 6.5 kg

Documentation

Compliance IEC/EN 61000-4-6, Annex A
Nominal frequency range 150 kHz – 80 MHz
Usable frequency range 10 kHz – 1 GHz
Nominal impedance 248 Ω
Impedance range ~ 230Ω – 260 Ω
RF connectors N-Female
Centre conductor height adjustable, ~ 47 mm – 75 mm
Centre conductor material ⌀ 4 mm, brass, nickel gold plated
Spacing between brackets 652 mm
Ground plane dimensions 1066 x 500 mm
Panel material Aluminium 6061