All the numerous advantages of compactness, robustness, reliability, and saving offered with the double resonance technology are already available on these models which constitute the low end range.
Five series of power are offered: 300 W, 600 W, 1200 W, 1500 W and 3000 W
These generators are all based on a 19’’ rack presentation with a 3U or 5U height depending on voltage and power proposed.
Using a modular design, our products integrate the latest technology components.
Above 20 kV, High Voltage subassembly is wrapped in resin or merged in a tank containing mineral oil. |
|
- Other Voltage and Current values available with no extracost *
- Reversibility and Floating outputs
- 4 1⁄2 digit display
- Non instrumented version
- Power regulation
- Arc Detection and counting
- RS232, GPIB and PROFIBUS interfaces
- Optic fibre transmission
- LABVIEW driver
- Relay interface
- Customer Remote Adaptation
- Single or multichannel consol unit
- Safety signs and devices alerting to Hazard
- Tropicalization
- Transportable “all terrain” container
- Specific AC or DC main power inputs
- OEM version
Any Special requests can be considered
|
|
| |
- Output Voltage and Output Current:
Both Voltage Output and Current Output are continuously
adjustable from 0 to 100 % (full scale)
In local mode: by using 10 turns potentiometers resolution
0.05%
In remote mode: by an external 0 to 10 V
- Voltage regulation:
Load Regulation: ± 0.05 % of full voltage (for 0 – 100 % load
change); ± 0.01% available on request.
Line Regulation: ± 0.05 % of full voltage ( for Main Voltage
± 10 %); ± 0.01% available on request.
- Current regulation:
Load Regulation: ± 0.05 % (for 0 – 100 % load change)
Line Regulation: ± 0.05 % (for Main Voltage ± 10 %)
- Ripple + Noise:
0.1 % p-p for 3 phase models
0.1% RMS for single phase models
- Setting Time:
< 100 ms, 10 ms available on request
|
|
- Stability (after one hour warm-up):
0.01 % / hour, 0.03 % after / 8 hours of operating with
constant load and ambiant temperature.
- Temperature Coefficient:
100 ppm/°C
- Operating Temperature:
from 0 to 40°C
- Efficiency:
> 88 % full load
- Recovery Time After Arc:
< 1 mS
- Stored Energy:
1J / kW
- Cooling by air:
Dust filter fans for 5U and higher models
- Main Voltage:
230 VAC ± 10 % 47 – 63 Hz + Earth up to 1200 W
PFC 110 V to 365 V
400 VAC ± 10 % 47 – 63 Hz 3 Phases + Earth from 1500 W
- Power factor:
> 0.98
|
|