Model |
PWX1500L |
PWX1500ML |
PWX1500MH |
PWX1500H |
AC Input |
|
|
|
|
Nominal Input Rating |
100 Vac to 240 Vac, 50 Hz to 60 Hz, single phase |
100 Vac to 240 Vac, 50 Hz to 60 Hz, single phase |
100 Vac to 240 Vac, 50 Hz to 60 Hz, single phase |
100 Vac to 240 Vac, 50 Hz to 60 Hz, single phase |
Input Voltage Range |
85 Vac to 265 Vac |
85 Vac to 265 Vac |
85 Vac to 265 Vac |
85 Vac to 265 Vac |
Input Frequency Range |
47 Hz to 63 Hz |
47 Hz to 63 Hz |
47 Hz to 63 Hz |
47 Hz to 63 Hz |
Current (MAX) |
|
|
|
|
100Vac |
21A |
21A |
21A |
21A |
200Vac |
10.5A |
10.5A |
10.5A |
10.5A |
Inrush Current |
70 A or less |
70 A or less |
70 A or less |
70 A or less |
Power (MAX) |
2200 VA |
2200 VA |
2200 VA |
2200 VA |
Power Factor (TYP) |
0.99 (input voltage 100 V), 0.97 (input voltage 200 V) |
0.99 (input voltage 100 V), 0.97 (input voltage 200 V) |
0.99 (input voltage 100 V), 0.97 (input voltage 200 V) |
0.98 (input voltage 100 V),
0.96 (input voltage 200 V) |
Efficiency |
74 % or greater |
74 % or greater |
74 % or greater |
74 % or greater |
Hold-up time for power interruption |
20 ms or greater |
20 ms or greater |
20 ms or greater |
20 ms or greater |
Output |
|
|
|
|
Rating |
|
|
|
|
Output Voltage |
30V |
80V |
230V |
650V |
Output Current |
150A |
56A |
20A |
7A |
Output Power |
1500W |
1500W |
1500W |
1500W |
Voltage |
|
|
|
|
Setting range |
0 V to 31.5 V |
0 V to 84 V |
0 V to 241.5 V |
0 V to 682.5 V |
Setting accuracy |
± (0.05 % of set +0.05 % of rating) |
± (0.05 % of set +0.05 % of rating) |
± (0.05 % of set +0.05 % of rating) |
± (0.05 % of set +0.05 % of rating) |
Line regulation |
± 5 mV |
± 10 mV |
± 25 mV |
± 67 mV |
Load regulation |
± 5 mV |
± 10 mV |
± 25 mV |
± 67 mV |
Transient response |
1 ms or less |
1 ms or less |
7 ms or less |
7 ms or less |
Ripple noise |
p-p: 60mV
rms: 8mV |
p-p: 80mV
rms: 8mV |
p-p: 120mV
rms: 25mV |
p-p: 330mV
rms: 60mV |
Rise time |
Rated Load: 100 ms
No Load: 100 ms |
Rated Load: 100 ms
No Load: 100 ms |
Rated Load: 100 ms
No Load: 100 ms |
Rated Load: 100 ms
No Load: 100 ms |
Fall time |
Rated Load: 100ms
No Load: 800ms |
Rated Load: 100ms
No Load: 1000ms |
Rated Load: 150ms
No Load: 1500ms |
Rated Load: 250ms
No Load: 3000ms |
Maximum remote sensing compensation voltage (single line) |
1.5V |
4V |
5V |
5V |
Temperature coefficient (MAX) |
100 ppm/°C (during external control) |
100 ppm/°C (during external control) |
100 ppm/°C (during external control) |
100 ppm/°C (during external control) |
Current |
|
|
|
|
Setting range |
0 A to 157.5 A |
0 A to 58.8 A |
0 A to 21 A |
0 A to 7.35 A |
Setting accuracy |
±(0.5 % of set +0.1 % of rating) |
±(0.5 % of set +0.1 % of rating) |
±(0.5 % of set +0.1 % of rating) |
±(0.5 % of set +0.1 % of rating) |
Line regulation |
± 17 mA |
± 7.6 mA |
± 4 mA |
± 2.7 mA |
Load regulation |
± 35 mA |
± 16.2 mA |
± 9 mA |
± 6.4 mA |
Ripple Noise (rms) |
300mA |
130 mA |
60 mA |
30 mA |
Temperature Coefficient (TYP) |
100 ppm/°C |
100 ppm/°C |
100 ppm/°C |
100 ppm/°C |