CONTACT
TEL: 0118 978 6911
NQA ISO9001 logo

Author Archive

Siglent SDS5000X Bandwidth Upgrade Offer

Posted on: July 21st, 2021 by James
21/07/2021
Free Bandwidth Upgrade (Value from £1,845.00) Purchase any SDS5000X Series Oscilloscope and receive a free bandwidth upgrade to the next highest bandwidth model Offer Valid Until 30-9-2021   To see the SDS5000X Category Page please see HERE...

Siglent release NEW SNA5000A Vector Network Analyser

Posted on: July 20th, 2021 by James
20/07/2021
SIGLENT presents its first vector network analyser and the first device of its new “A” performance line With the continuous growth of radio and cellular networks, the increase in data traffic and increasing data rates, the...

Siglent SPS5000X Special Launch Price!

Posted on: July 9th, 2021 by James
09/07/2021
Following the launch of Siglent's new SPS5000X Series DC Power Supplies, all prices have a special 10% discount until the 30/09/2021....

End of Line Kikusui PWR400L DC Power Supply

Posted on: June 30th, 2021 by James
30/06/2021
To view the PWR400L product page please see HERE...

End of Line Kikusui PAS40-9 DC Power Supply

Posted on: June 30th, 2021 by James
30/06/2021
To view the PAS40-9 product page please see HERE...

End of Line Kikusui PWR1600H DC Power Supply

Posted on: June 30th, 2021 by James
30/06/2021
To view the PWR1600H product page please see HERE...

End of Line Kikusui PAN60-6A DC Power Supply

Posted on: June 30th, 2021 by James
30/06/2021
To view the PAN60-6A product page please see HERE...

DC Electronic Load – Part 4: How Each Operation Mode Works with Other Modes?

Posted on: June 23rd, 2021 by James
DC Electronic Load – Part 4: How Each Operation Mode Works with Other Modes? 23/06/2021
We have so far explained the four major operation modes for electronic loads - 1) constant current 2) constant resistance 3) constant voltage and 4) constant power, in the previous white papers. Now this paper describes how these modes relate to each other and how each mode works on other modes. 4-1. Relationship between Operation Modes Figure 4-1 shows the block diagram for the...

How to Double Output Voltage from Two PBZ through BTL* Connection

Posted on: June 23rd, 2021 by James
How to Double Output Voltage from Two PBZ through BTL* Connection 23/06/2021
Here is an introduction on a method to achieve a double output voltage using two units of PBZ. The actual connection of PBZs is shown in Figure 1 as; -‘OUT’ terminals are used for output. - Only ‘COM’ terminal can be earthed for output, if required. Fo...

Useful Functions and Precautions for Using L-Load/C-Load in PCR-LE Series

Posted on: June 23rd, 2021 by James
Useful Functions and Precautions for Using  L-Load/C-Load in PCR-LE Series 23/06/2021
1. When Using Inductive Load (L-Load) 1-1 Soft Start A typical L-load is a motor load. E.g.) If using an induction motor load, the startup current can be 5 times (or more) larger than the normal startup current and it flows for several hundred ms. In this situation; 1) The motor load becomes inductive. 2) The power factor is approx. 0.5 at peak current. PCR-LE...

Which Power Supply is Most Suitable to Run DC Motor?

Posted on: June 23rd, 2021 by James
Which Power Supply is Most Suitable to Run DC Motor? 23/06/2021
When choosing a power supply to run a DC motor, the first and most important thing you need to consider is a maximum current that your motor will use. DC motor typically requires a startup current which is quite a lot higher than its running current. Due to this, not all DC power supplies can provide sufficient power to DC motors. In this white paper, we will take a look at the capability of our ...

How to Balance Battery Module Charge-Discharge

Posted on: June 23rd, 2021 by James
How to Balance Battery Module Charge-Discharge 23/06/2021
With the recent diversification of battery module application such as for automotive and backup, more and more users want to conduct a battery module charge-discharge test, besides of an individual cell battery test. As a battery management system has been greatly developed to maximize battery’s capacity, the practical needs to perform evaluations on balancing battery charge-discharge are incre...

Sub Categories

AC Power Supplies / Frequency Converters Offers & Promotions (1)

Application Notes (45)

Blog (70)

DC Power Supplies Offers & Promotions (6)

Digital Multimeters Offers & Promotions (1)

Digital Oscilloscopes Offers & Promotions (8)

Electronic Loads Offers & Promotions (1)

Knowledge Base AC Power Supplies

Knowledge Base Data Acquisition Systems

Knowledge Base DC Power Supplies

Knowledge Base DG1000 Series (14)

Knowledge Base DG4000 Series (14)

Knowledge Base Digital Multimeters

Knowledge Base Digital Oscilloscopes

Knowledge Base DL3000 Series (2)

Knowledge Base DM3000 Series (21)

Knowledge Base DP700 Series (8)

Knowledge Base DP800 Series (26)

Knowledge Base DS1000 Series (46)

Knowledge Base DS2000 Series (36)

Knowledge Base DSA800 Series (70)

Knowledge Base DSG800 Series (2)

Knowledge Base Electrical Safety Analysers

Knowledge Base Electronic Loads

Knowledge Base M300 Series (2)

Knowledge Base MSO/DS7000 Series (35)

Knowledge Base MSO5000 Series (35)

Knowledge Base MSO8000 Series (32)

Knowledge Base PBZ Series (3)

Knowledge Base PCR-LE Series (3)

Knowledge Base PCR-MA Series (3)

Knowledge Base PCR-WE/WE2 Series (3)

Knowledge Base PLZ-5W Series (3)

Knowledge Base PLZ-5WH Series (3)

Knowledge Base PLZ-5WH2 Series (3)

Knowledge Base PMX-Multi Series (3)

Knowledge Base PWR-01 Series (3)

Knowledge Base RF Signal Generators

Knowledge Base RSA3000 Series (32)

Knowledge Base RSA5000 Series (31)

Knowledge Base SDG1000X Series (10)

Knowledge Base SDG2000X Series (11)

Knowledge Base SDG6000X Series (11)

Knowledge Base SDG800 Series (10)

Knowledge Base SDL1000X Series (5)

Knowledge Base SDM3000 Series (6)

Knowledge Base SDS1000X-E Series (15)

Knowledge Base SDS2000X-E Series (15)

Knowledge Base SDS5000X Series (15)

Knowledge Base SPD1000X (5)

Knowledge Base SPD3000X/X-E Series (6)

Knowledge Base Spectrum Analysers

Knowledge Base SSA3000X Plus Series (2)

Knowledge Base SSA3000X Series (15)

Knowledge Base SSA3000X-R Series (1)

Knowledge Base SSG3000X Series (4)

Knowledge Base SVA1000X Series (13)

Knowledge Base TOS9300 Series (3)

Knowledge Base Waveform Generators

LCR Meters Offers & Promotions (1)

Safety Testers Offers & Promotions (1)

Spectrum Analysers Offers & Promotions (3)

Telonic Instruments News & Events (3)

Telonic Offers & Promotions (1)

CLICK TO CALL

0118 9786911
CLICK TO EMAIL